Differences in kinematics and kinetics during gait between total knee arthroplasty implant designs

被引:0
|
作者
Nishizawa, Kohei [1 ]
Harato, Kengo [1 ]
Hakukawa, Satoshi [1 ]
Kobayashi, Shu [1 ]
Niki, Yasuo [2 ]
Nagura, Takeo [3 ]
机构
[1] Keio Univ, Sch Med, Dept Orthopaed Surg, 35 Shinanomachi,Shinjuku Ku, Tokyo 1608582, Japan
[2] Fujita Med Innovat Ctr, Dept Orthopaed Surg, Ohta Ku, Tokyo, Japan
[3] Keio Univ, Sch Med, Dept Clin Biomech, Shinjuku Ku, Tokyo, Japan
关键词
Total knee arthroplasty; Bi-cruciate stabilized total knee arthroplasty; Gait analysis; Kinematics; STABILIZED TOTAL KNEE; REPLACEMENT; POSTERIOR; STAIR; SATISFACTION; OUTCOMES; FLEXION; MOTION;
D O I
10.1016/j.clinbiomech.2024.106404
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Implant design is important for achieving proper knee biomechanics during gait following knee arthroplasty. Bicruciate-stabilized total knee arthroplasty attempts to replicate anterior stability and rotational facilitation. However, its detailed gait biomechanics compared with other implant designs have not been analyzed. The purpose of this study is to compare knee kinematics and kinetics between bicruciate-stabilized total knee arthroplasty, posterior-stabilized total knee arthroplasty, unicompartmental knee arthroplasty, and normal knees. Methods: Ten healthy subjects, 16 who underwent posterior stabilized total knee arthroplasty, 12 who underwent bicruciate-stabilized total knee arthroplasty, and 13 who underwent unicompartmental knee arthroplasty were recruited. The mean follow-up period after arthroplasty was 11.0 months. Three-dimensional kinematics and kinetics were assessed using a motion capture system with subjects walking on a 5-m walkway. Comparisons between groups were conducted using the Kruskal-Wallis test, and post hoc analysis was performed for those parameters that differed significantly. Findings: The bicruciate-stabilized total knee arthroplasty group showed decreased internal rotation compared to the unicompartmental knee arthroplasty group. Compared to the control group, the posterior-stabilized total knee arthroplasty group exhibited reduced knee extension and internal rotation moment. Interpretation: Bicruciate-stabilized total knee arthroplasties exhibited different biomechanical characteristics compared to unicompartmental knee arthroplasties during terminal stance. Postoperative total knee arthroplasty rehabilitation should focus on relieving stiffness owing to insufficient knee flexion-extension motion observed in both bicruciate-stabilized and posterior-stabilized total knee arthroplasties compared with unicompartmental knee arthroplasty, which may be due to a lack of knee rotational motion during gait.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] The Effect of Total Knee Arthroplasty on Knee Joint Kinematics and Kinetics During Gait
    Hatfield, Gillian L.
    Hubley-Kozey, Cheryl L.
    Wilson, Janie L. Astephen
    Dunbar, Michael J.
    JOURNAL OF ARTHROPLASTY, 2011, 26 (02) : 309 - 318
  • [2] Impact of implant positions in total knee arthroplasty on the postoperative knee kinematics of tibial rotation
    Hanada, Mitsuru
    Hotta, Kensuke
    Matsuyama, Yukihiro
    JOURNAL OF ORTHOPAEDICS, 2024, 58 : 24 - 28
  • [3] Intraoperative passive knee kinematics during total knee arthroplasty surgery
    Young, Kathryn L.
    Dunbar, Michael J.
    Richardson, Glen
    Wilson, Janie L. Astephen
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2015, 33 (11) : 1611 - 1619
  • [4] Comparison of long-term kinematics and wear of total knee arthroplasty implant designs
    Bourdon, Caleigh E.
    Broberg, Jordan S.
    McCalden, Richard W.
    Naudie, Douglas D.
    MacDonald, Steven J.
    Lanting, Brent A.
    Teeter, Matthew G.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 124
  • [5] Lower extremity gait kinematics outcomes after knee replacement demonstrate arthroplasty-specific differences between unicondylar and total knee arthroplasty: A pilot study
    De Vroey, Henri
    Staes, Filip
    Vereecke, Evie
    Vanrenterghem, Jos
    Deklerck, Jan
    Van Damme, Geert
    Hallez, Hans
    Claeys, Kurt
    GAIT & POSTURE, 2019, 73 : 299 - 304
  • [6] In Vivo Knee Kinematics in Patients With Bilateral Total Knee Arthroplasty of 2 Designs
    Okamoto, Nobukazu
    Breslauer, Leigh
    Hedley, Anthony K.
    Mizuta, Hiroshi
    Banks, Scott A.
    JOURNAL OF ARTHROPLASTY, 2011, 26 (06) : 914 - 918
  • [7] Non-Sagittal Knee Joint Kinematics and Kinetics during Gait on Level and Sloped Grounds with Unicompartmental and Total Knee Arthroplasty Patients
    Komnik, Igor
    Peters, Markus
    Funken, Johannes
    David, Sina
    Weiss, Stefan
    Potthast, Wolfgang
    PLOS ONE, 2016, 11 (12):
  • [8] Sex Differences in Gait After Total Knee Arthroplasty
    McClelland, Jodie A.
    Feller, Julian A.
    Webster, Kate E.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (03) : 897 - 902
  • [9] In Vivo Kinematics and Kinetics of a Bi-Cruciate Substituting Total Knee Arthroplasty: A Combined Fluoroscopic and Gait Analysis Study
    Catani, Fabio
    Ensini, Andrea
    Belvedere, Claudio
    Feliciangeli, Alessandro
    Benedetti, Maria Grazia
    Leardini, Alberto
    Giannini, Sandro
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2009, 27 (12) : 1569 - 1575
  • [10] Correlation Between Knee Kinematics and Patellofemoral Contact Pressure in Total Knee Arthroplasty
    Konno, Takuya
    Onodera, Tomohiro
    Nishio, Yusuke
    Kasahara, Yasuhiko
    Iwasaki, Norimasa
    Majima, Tokifumi
    JOURNAL OF ARTHROPLASTY, 2014, 29 (12) : 2305 - 2308