Determination of Trace Cobalt in Water Samples by Ionic Liquid-Dispersive Liquid-Liquid Microextraction and Graphite Furnace Atomic Absorption Spectrometry

被引:0
|
作者
Liu, Yaqi [1 ]
Han, Quan [1 ,2 ]
Huo, Yanyan [2 ]
Yang, Xiaohui [2 ]
机构
[1] Yanan Univ, Sch Chem & Chem Engn, Yanan 716000, Peoples R China
[2] Xian Univ, Sch Chem Engn, Xian 710065, Peoples R China
关键词
cobalt; 2-(5-bromo-2-pyridylazo)-5-dimethylaminobenzenamine; ionic liquid; dispersive liquid-liquid microextraction; graphite furnace atomic absorption spectrometry; SINGLE-DROP MICROEXTRACTION; NICKEL; EXTRACTION;
D O I
10.3103/S1063455X24050102
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A new method for the determination of ultra-trace cobalt by ionic liquid-dispersive liquid-liquid microextraction (IL-DLLME) and graphite furnace atomic absorption spectrometry (GFAAS) was developed. The trace cobalt was extracted by DLLME using the homemade reagent 2-(5-bromo-2-pyridylazo)-5-dimethylaminobenzenamine (5-Br-PADMA) as chelating agent, the ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate ([C6mim][PF6]) as extractant, and acetonitrile (CH3CN) as dispersing agent, and then determined by GFAAS. The factors affecting the cobalt extraction efficiency: the type and volume of extraction solvent and dispersive solvent, the concentration and dosage of chelating agent, and the pH of the solution, were explored using the one-way rotation method. Under the optimized conditions, the cobalt concentration showed excellent linearity in the range of 0.05-1.50 ng/mL with the detection limit of 0.026 ng/mL; the relative standard deviation (RSD) for the determination of the cobalt standard solution with the mass concentration of 1.0 ng/mL was 4.83% (n = 9). From the slope of the linear regression equation for the determination of cobalt obtained after extraction compared with that before extraction, the enrichment factor of the method was found to be 62, and the spiked recoveries were in the range of 94.0-104.4%. The method is characterized by low detection limit, high sensitivity, and environment friendliness as well as convenient and rapid operation for the determination of trace cobalt in water samples. The results of this method are satisfactory.
引用
收藏
页码:480 / 490
页数:11
相关论文
共 50 条
  • [41] Dispersive Liquid-Liquid Microextraction of Bismuth in Various Samples and Determination by Flame Atomic Absorption Spectrometry
    Dasbasi, Teslima
    Kartal, Senol
    Sacmaci, Serife
    Ulgen, Ahmet
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2016, 2016
  • [42] Rapid determination of lead in water samples by dispersive liquid-liquid microextraction coupled with electrothermal atomic absorption spectrometry
    Naseri, Mohammad Taghi
    Hosseini, Mohammad Reza Milani
    Assadi, Yaghoub
    Kiani, Armin
    TALANTA, 2008, 75 (01) : 56 - 62
  • [43] Combination of dispersive liquid-liquid microextraction and flame atomic absorption spectrometry for preconcentration and determination of copper in water samples
    Khani, Rouhollah
    Shemirani, Farzaneh
    Majidi, Behrooz
    DESALINATION, 2011, 266 (1-3) : 238 - 243
  • [44] Determination of Trace Amounts of Nickel in Food and Environmental Water Samples by Flame Atomic Absorption Spectrometry after Dispersive Liquid-Liquid Microextraction
    Mirabi, A.
    Jamali, M. R.
    Mehraeen, P.
    Berijani, K.
    ASIAN JOURNAL OF CHEMISTRY, 2012, 24 (08) : 3425 - 3429
  • [45] Determination of trace silver in water, wastewater and ore samples using dispersive liquid-liquid microextraction coupled with flame atomic absorption spectrometry
    Rastegarzadeh, Saadat
    Pourreza, Nahid
    Larki, Arash
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2015, 24 : 297 - 301
  • [46] Ligandless dispersive liquid-liquid microextraction for the separation of trace amounts of silver ions in water samples and flame atomic absorption spectrometry determination
    Mohammadi, Sayed Zia
    Afzali, Daryoush
    Taher, Mohammad Ali
    Baghelani, Yar Mohammad
    TALANTA, 2009, 80 (02) : 875 - 879
  • [47] In situ ionic liquid dispersive liquid-liquid microextraction and determination of Au(III) by flame atomic absorption spectrometry
    Sha, Ou
    Chen, Juan
    Chen, Li
    Li, Shuan
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2015, 12 (08) : 1391 - 1398
  • [48] Determination of trace levels of cobalt ion in different real samples using dispersive liquid-liquid microextraction followed by flame atomic absorption spectrometry
    Beikzadeh, Elham
    Sarrafi, Amir H. M.
    JOURNAL OF FOOD MEASUREMENT AND CHARACTERIZATION, 2017, 11 (03) : 994 - 1002
  • [49] Speciation of Arsenic in Drinking Water by Dispersive Liquid-Liquid Microextraction, Graphite Furnace Atomic Absorption Spectrometry, and Orthogonal Array Design
    Zhang, Yumei
    Fang, Lanyun
    Wang, Li
    ANALYTICAL LETTERS, 2017, 50 (05) : 853 - 865
  • [50] Trace determination of lead in lipsticks and hair dyes using microwave-assisted dispersive liquid-liquid microextraction and graphite furnace atomic absorption spectrometry
    Sharafi, K.
    Fattahi, N.
    Pirsaheb, M.
    Yarmohamadi, H.
    Davil, M. Fazlzadeh
    INTERNATIONAL JOURNAL OF COSMETIC SCIENCE, 2015, 37 (05) : 489 - 495