Determination of Trace Cobalt in Water Samples by Ionic Liquid-Dispersive Liquid-Liquid Microextraction and Graphite Furnace Atomic Absorption Spectrometry

被引:0
|
作者
Liu, Yaqi [1 ]
Han, Quan [1 ,2 ]
Huo, Yanyan [2 ]
Yang, Xiaohui [2 ]
机构
[1] Yanan Univ, Sch Chem & Chem Engn, Yanan 716000, Peoples R China
[2] Xian Univ, Sch Chem Engn, Xian 710065, Peoples R China
关键词
cobalt; 2-(5-bromo-2-pyridylazo)-5-dimethylaminobenzenamine; ionic liquid; dispersive liquid-liquid microextraction; graphite furnace atomic absorption spectrometry; SINGLE-DROP MICROEXTRACTION; NICKEL; EXTRACTION;
D O I
10.3103/S1063455X24050102
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A new method for the determination of ultra-trace cobalt by ionic liquid-dispersive liquid-liquid microextraction (IL-DLLME) and graphite furnace atomic absorption spectrometry (GFAAS) was developed. The trace cobalt was extracted by DLLME using the homemade reagent 2-(5-bromo-2-pyridylazo)-5-dimethylaminobenzenamine (5-Br-PADMA) as chelating agent, the ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate ([C6mim][PF6]) as extractant, and acetonitrile (CH3CN) as dispersing agent, and then determined by GFAAS. The factors affecting the cobalt extraction efficiency: the type and volume of extraction solvent and dispersive solvent, the concentration and dosage of chelating agent, and the pH of the solution, were explored using the one-way rotation method. Under the optimized conditions, the cobalt concentration showed excellent linearity in the range of 0.05-1.50 ng/mL with the detection limit of 0.026 ng/mL; the relative standard deviation (RSD) for the determination of the cobalt standard solution with the mass concentration of 1.0 ng/mL was 4.83% (n = 9). From the slope of the linear regression equation for the determination of cobalt obtained after extraction compared with that before extraction, the enrichment factor of the method was found to be 62, and the spiked recoveries were in the range of 94.0-104.4%. The method is characterized by low detection limit, high sensitivity, and environment friendliness as well as convenient and rapid operation for the determination of trace cobalt in water samples. The results of this method are satisfactory.
引用
收藏
页码:480 / 490
页数:11
相关论文
共 50 条
  • [21] Selective Determination of Lead in Complicated Environmental Samples by Displacement Dispersive Liquid-liquid Microextraction and Graphite Furnace Atomic Absorption Spectrometry
    Liang, Pei
    Kang, Caiyan
    Wen, Lijuan
    ATOMIC SPECTROSCOPY, 2016, 37 (01) : 30 - 35
  • [22] Determination of Cadmium and Lead in Human Teeth Samples Using Dispersive Liquid-liquid Microextraction and Graphite Furnace Atomic Absorption Spectrometry
    Zhang, Chunyan
    Wang, Yining
    Cheng, Xiangrong
    Xia, Haibin
    Liang, Pei
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2011, 58 (07) : 919 - 924
  • [23] Determination of trace amounts of manganese in water samples by flame atomic absorption spectrometry after dispersive liquid-liquid microextraction
    Mirabi, A.
    Jamali, M. R.
    Kazemi, Q.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2016, 48 (03): : 525 - 531
  • [24] Dispersive Liquid-Liquid Microextraction Combined with Electrothermal Atomic Absorption Spectrometry for Determination of Trace Lead in Drinking Water Samples
    Liu, Y. L.
    Wu, X. Y.
    Xiang, G. Q.
    He, L. J.
    Jiang, X. M.
    Zhang, H. X.
    Chen, F. P.
    ASIAN JOURNAL OF CHEMISTRY, 2011, 23 (09) : 4049 - 4052
  • [25] Displacement-dispersive liquid-liquid microextraction coupled with graphite furnace atomic absorption spectrometry for the selective determination of trace silver in environmental and geological samples
    Liang, Pei
    Zhang, Linlin
    Zhao, Ehong
    TALANTA, 2010, 82 (03) : 993 - 996
  • [26] Graphite Furnace Atomic Absorption Spectrometry After Dispersive Liquid-Liquid Microextraction for the Determination of Selenium in the Anodic Slime
    Mohammadi, Sayed Zia
    Afzali, Daryoush
    Arabpour, Farzaneh
    COMMUNICATIONS IN SOIL SCIENCE AND PLANT ANALYSIS, 2017, 48 (21) : 2496 - 2505
  • [27] Supramolecular solvent dispersive liquid-liquid microextraction based on solidification of floating drop and graphite furnace atomic absorption spectrometry for the determination of trace lead in food and water samples
    Liang, Pei
    Yang, Enjian
    Yu, Juan
    Wen, Lijuan
    ANALYTICAL METHODS, 2014, 6 (11) : 3729 - 3734
  • [28] Determination of Trace Levels of Lead in Water Samples by Graphite Furnace Atomic Absorption Spectrometry After Dispersive Liquid-liquid Microextraction Based on Solidification of Floating Organic Drop
    Liang, Pei
    Yu, Juan
    Yang, Enjian
    Peng, Lili
    ATOMIC SPECTROSCOPY, 2014, 35 (02) : 85 - 89
  • [29] Ionic Liquid-Based Dispersive Liquid-Liquid Microextraction Combined with Flame Atomic Absorption Spectrometry for Determination of Silver in Water Samples
    Abadi, M. Dehghani Mohammad
    Chamsaz, M.
    Arbab-Zavar, M. H.
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 (07) : 3984 - 3988
  • [30] In situ metathesis ionic liquid formation dispersive liquid-liquid microextraction for copper determination in water samples by electrothermal atomic absorption spectrometry
    Stanisz, Ewa
    Zgola-Grzeskowiak, Agnieszka
    TALANTA, 2013, 115 : 178 - 183