Mid- to long-term clinical and radiological assessment of a short, titanium, porous plasma-splayed flat-tapered cementless femoral stem: An 8-to 12-year follow-up study

被引:0
作者
Yoshino, Kensuke [1 ]
Harada, Yoshitada [1 ]
Miyagi, Jin [1 ]
Ogawa, Yuya [1 ]
Nagai, Akito [1 ]
机构
[1] Chibaken Saiseikai Narashino Hosp, Dept Orthopaed Surg, 1-1-1 Izumi cho, Narashino, Chiba 2758580, Japan
关键词
Short cementless stem; Total hip arthroplasty; Mid-term; Clinical results; Survival rate; Stress shielding; TOTAL HIP-ARTHROPLASTY; PERFORMANCE; REPLACEMENT; COMPONENT; OUTCOMES;
D O I
10.1007/s00402-024-05712-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Short cementless stems offer advantages such as bone-stock preservation and minimally invasive insertion. Despite encouraging short- to midterm outcomes, the long-term clinical and radiological implications of short, titanium, and porous plasma-sprayed flat-tapered stems remain unclear. Materials and methods: A retrospective review of 138 primary total hip arthroplasties, conducted between 2010 and 2015 in 130 patients, with a minimum 8-year follow-up was performed. Patients with Dorr type A or B femora were included. Clinical and radiographic results, complications, and survival rates were evaluated. Results: A total of 102 hips (94 patients) were reviewed with complete clinical and radiographic data at a minimum 8-year follow-up (mean, 9.5 years). The modified Harris hip score significantly improved from a mean preoperative value of 40.1 to 97.8 at the final follow-up, with 91% of the hips achieving a score of >= 90. In the original cohort of 138 hips, none underwent revision surgery for symptomatic loosening. Perioperative complications occurred in eight hips, including femoral fractures, postoperative dislocation, subcutaneous abscess, and transient thigh pain. Radiographically, femoral stem alignment was predominantly neutral in 86% of the hips in the anteroposterior plane. No hip exhibited radiolucency > 1 mm, and no subsidence > 2 mm was observed. Bone ingrowth fixation was observed in all 102 hips. Stress shielding around or below the lesser trochanter occurred in 58% of hips. Kaplan-Meier survival analysis indicated a 100% survival rate at eight, 10, and 12 years for stem revision or radiological instability. Conclusions: The short, titanium, porous, plasma-sprayed, flat-tapered cementless stem exhibited excellent mid- to long-term results in primary total hip arthroplasties with Dorr type A or B femora, comparable with those of other short cementless and standard-length stems. Noteworthy survivorship was observed; however, caution is advised regarding stress-shielding complications, particularly periprosthetic femoral fractures, during extended follow-up.
引用
收藏
页数:9
相关论文
共 26 条
[1]  
Adams JB, 2009, ORTHOPEDICS, V32
[2]   The Short and "Shorter" of It: >1750 Tapered Titanium Stems at 6-to 88-Month Follow-Up [J].
Barrington, John W. ;
Emerson, Roger H., Jr. .
JOURNAL OF ARTHROPLASTY, 2013, 28 (08) :38-40
[3]   Prospective analysis of hip arthroscopy with 2-year follow-up [J].
Byrd, JWT ;
Jones, KS .
ARTHROSCOPY, 2000, 16 (06) :578-587
[4]   Minimum 10-Year Follow-Up of Cementless Total Hip Arthroplasty Using a Contemporary Triple-Tapered Titanium Stem [J].
Carlson, Samuel W. ;
Goetz, Devon D. ;
Liu, Steve S. ;
Greiner, Justin J. ;
Callaghan, John J. .
JOURNAL OF ARTHROPLASTY, 2016, 31 (10) :2231-2236
[5]   Bone Remodeling Characteristics of a Short-Stemmed Total Hip Replacement [J].
Chen, Hsiang-Ho ;
Morrey, Bernard F. ;
An, Kai-Nan ;
Luo, Zong-Ping .
JOURNAL OF ARTHROPLASTY, 2009, 24 (06) :945-950
[6]   STRUCTURAL AND CELLULAR ASSESSMENT OF BONE QUALITY OF PROXIMAL FEMUR [J].
DORR, LD ;
FAUGERE, MC ;
MACKEL, AM ;
GRUEN, TA ;
BOGNAR, B ;
MALLUCHE, HH .
BONE, 1993, 14 (03) :231-242
[7]   POROUS-COATED HIP-REPLACEMENT - THE FACTORS GOVERNING BONE INGROWTH, STRESS SHIELDING, AND CLINICAL-RESULTS [J].
ENGH, CA ;
BOBYN, JD ;
GLASSMAN, AH .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (01) :45-55
[8]   Early clinical and radiological outcomes for the Taperloc Complete Microplasty stem [J].
Gallart, Xavier ;
Fernandez-Valencia, Jenaro A. ;
Rios, Gina ;
Bori, Guillem ;
Riba, Josep ;
Munoz-Mahamud, Ernesto ;
Combalia, Andres .
EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2019, 29 (03) :619-624
[9]  
GRUEN TA, 1979, CLIN ORTHOP RELAT R, P17
[10]   Clinical results of a short stem with flat tapered wedge design in primary total hip arthroplasty for hip dysplasia in Asians [J].
Hayama, Tetsuo ;
Otani, Takuya ;
Fujii, Hideki ;
Kawaguchi, Yasuhiko ;
Abe, Toshiomi ;
Takahashi, Motoi ;
Saito, Mitsuru .
JOURNAL OF ORTHOPAEDIC SURGERY, 2020, 28 (03)