The study of indoor particulate matter in office buildings based on artificial intelligence

被引:0
|
作者
Soleimani-Alyar, S. [1 ]
Soleimani-Alyar, M. [1 ]
Yarahmadi, R. [2 ]
Beyk-Mohammadloo, P. [1 ]
Fazeli, P. [1 ]
机构
[1] Iran Univ Med Sci IUMS, Air Pollut Res Ctr, Tehran, Iran
[2] Iran Univ Med Sci IUMS, Air Pollut Res Ctr, Sch Publ Hlth, Dept Occupat Hlth, Tehran, Iran
关键词
Indoor air quality; Particulate matter; Machine learning; Forecasting; Ensemble algorithms; APPROPRIATE USE; AIR-POLLUTION; PM2.5; PM10; STATISTICS; SCHOOLS; MODELS;
D O I
10.1007/s13762-024-06277-1
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The necessity of supplying proper indoor air quality in workplaces to provide the principles of a healthy and productive labor force and avoid negative outcomes is a known fact. This study assessed particulate matter (PM) concentrations in office buildings of governmental organizations across five regions in Tehran over four seasons (2018-2019) to model annual indoor PM patterns using machine learning. PM concentrations, including PM1, PM2.5, PM10, and Total Particulate Matter (TPM), were categorized using ensemble modeling techniques such as Linear Regression, Random Forest, Gradient Boosting, XGBoost, CatBoost, Support Vector Regression, and K-nearest neighbors. Key air quality parameters measured were CO2 (784 ppm), SO2 (0.114 mu g/m3), PM2.5 (4.604 mu g/m3), temperature (24.8 degrees C), and relative humidity (21.16%). While most parameters met guidelines, PM10 levels (97.5 mu g/m3) exceeded WHO standards and relative humidity was below recommended levels, highlighting areas for improvement. PM2.5 and PM10 showed the strongest positive correlation (p value = 0.0001) and similar seasonal trends, with higher concentrations in autumn and summer and lower levels in spring and winter. The southern region exhibited consistently higher PM concentrations, while no significant changes were noted in the East or West. Among the models, CatBoost performed best in predicting air quality. The study suggests that indoor PM levels are influenced by psychrometric conditions and building location, providing valuable insights for improving air quality and occupant health.
引用
收藏
页码:5763 / 5776
页数:14
相关论文
共 50 条
  • [41] Influence of different indoor activities on the indoor particulate levels in residential buildings
    Chao, CYH
    Tung, TCW
    Burnett, J
    INDOOR AND BUILT ENVIRONMENT, 1998, 7 (02) : 110 - 121
  • [42] Artificial intelligence-based prediction of indoor bioaerosol concentrations from indoor air quality sensor data
    Lee, Justin Y. Y.
    Miao, Yanhao
    Chau, Ricky L. T.
    Hernandez, Mark
    Lee, Patrick K. H.
    ENVIRONMENT INTERNATIONAL, 2023, 174
  • [43] Assessment of indoor air quality in office buildings across Europe - The OFFICAIR study
    Mandin, Corinne
    Trantallidi, Marilena
    Cattaneo, Andrea
    Canha, Nuno
    Mihucz, Victor G.
    Szigeti, Tamas
    Mabilia, Rosanna
    Perreca, Erica
    Spinazze, Andrea
    Fossati, Serena
    De Kluizenaar, Yvonne
    Cornelissen, Eric
    Sakellaris, Ioannis
    Saraga, Dikaia
    Hanninen, Otto
    Fernandes, Eduardo De Oliveira
    Ventura, Gabriela
    Wolkoff, Peder
    Carrer, Paolo
    Bartzis, John
    SCIENCE OF THE TOTAL ENVIRONMENT, 2017, 579 : 169 - 178
  • [44] Assessment of fungal bioaerosols and particulate matter characteristics in indoor and outdoor air of veterinary clinics
    Mosalaei, Shamim
    Amiri, Hoda
    Rafiee, Ata
    Abbasi, Alireza
    Baghani, Abbas Norouzian
    Hoseini, Mohammad
    JOURNAL OF ENVIRONMENTAL HEALTH SCIENCE AND ENGINEERING, 2021, 19 (02) : 1773 - 1780
  • [45] Patterns and disparities in indoor particulate matter levels in selected primary schools in Kigali, Rwanda
    Korukire, Noel
    Godson, Ana
    Mukamurigo, Judith
    Memunat, Akanbi Oyiza
    Izabayo, Josias
    Bashaija, David
    Ntakirutimana, Theoneste
    HELIYON, 2024, 10 (15)
  • [46] Robust machine intelligence for learning particulate matter variation around power complex
    Tutmez, Bulent
    MODELING EARTH SYSTEMS AND ENVIRONMENT, 2023, 9 (02) : 2141 - 2150
  • [47] Predictors of indoor fine particulate matter in infants' bedrooms in Denmark
    Raaschou-Nielsen, Ole
    Sorensen, Mette
    Hertel, Ole
    Chawes, Bo L. K.
    Vissing, Nadja
    Bonnelykke, Klaus
    Bisgaard, Hans
    ENVIRONMENTAL RESEARCH, 2011, 111 (01) : 87 - 93
  • [48] Dynamic of Particulate Matter for Quotidian Aerosol Sources in Indoor Air
    Mostafa, Mostafa Yuness Abdelfatah
    Khalaf, Hyam Nazmy Bader
    Zhukovsky, Michael V.
    ATMOSPHERE, 2021, 12 (12)
  • [49] Indoor concentrations of particulate matter 2.5 in a pediatric emergency service
    Cabral, Catiane Zanin
    Fleck, Alan da Silveira
    Amantea, Fernanda Chaves
    Rhoden, Claudia Ramos
    Amantea, Sergio Luis
    REVISTA PAULISTA DE PEDIATRIA, 2022, 40
  • [50] Application of DBD air plasma for indoor particulate matter removal
    Jangra, Ramavtar
    Ahlawat, Kiran
    Prakash, Ram
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2024, 179 (7-8): : 903 - 908