Fire performance of CFRP-strengthened piloti-type columns with fire-resistant materials during standard fire exposure

被引:0
|
作者
Shin, Jinwon [1 ]
Lee, Hansol [1 ]
Choi, In-Rak [2 ]
Min, Jeong-Ki [3 ]
Choi, Sung-Mo [4 ]
机构
[1] Catholic Kwandong Univ, Dept Architectural Engn, Kangnung, South Korea
[2] Hoseo Univ, Dept Civil Engn, Asan, South Korea
[3] Real Scale Fire Testing & Res Ctr, Korea Conform Labs, Samcheok, South Korea
[4] Univ Seoul, Dept Architectural Engn, Seoul, South Korea
来源
SCIENTIFIC REPORTS | 2024年 / 14卷 / 01期
基金
新加坡国家研究基金会;
关键词
Fire performance; Piloti-type RC buildings; CFRP strengthening; Insulation system; Coupled thermal-stress analysis; STRESS-STRAIN MODEL; CONFINED CONCRETE; FRP; BEHAVIOR; TEMPERATURE; ENDURANCE; BOND;
D O I
10.1038/s41598-024-74306-7
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This paper presents a numerical investigation into the fire endurance of carbon fiber reinforced polymer (CFRP)-strengthened columns, shielded with fire-resistant materials, in piloti-type reinforced concrete buildings. The strengthened column, equipped with a fire protection system, underwent exposure to the ASTM E119 standard time-temperature curve for a duration of 4 h. To comprehensively evaluate the thermal and structural performance of the strengthened column at elevated temperatures and substantiate the effectiveness of the fire protection system, a fully coupled thermal-stress analysis was conducted. The numerical modeling approach employed in this study was rigorously validated through previous experimental studies in conjunction with adherence to the ACI design guideline, specifically ACI 440.2R-17. Using the validated structural fire model, the thermal and structural behaviors of the RC column with an insulated CFRP strengthening system were investigated based on four key performance criteria: glass transition temperature, ignition temperature of polymer matrix, critical temperature of reinforcing bars, and the design axial load capacity at elevated temperatures. Furthermore, a comparative assessment of fire endurance was performed using diverse fire-resistant materials, including Sprayed Fire-Resistive Material (SFRM) and Sikacrete (R)-213 F, with insulation thicknesses ranging from 10 to 30 mm, during the 4-hour fire exposure period.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] FIRE RESISTANCE OF FIRE-RESISTANT STEEL COLUMNS
    SAKUMOTO, Y
    YAMAGUCHI, T
    OKADA, T
    YOSHIDA, M
    TASAKA, S
    SAITO, H
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1994, 120 (04): : 1103 - 1121
  • [2] Modeling the behavior of CFRP-strengthened RC slabs under fire exposure
    Assad, Maha
    Hawileh, Rami A.
    Abdalla, Jamal A.
    23 EUROPEAN CONFERENCE ON FRACTURE, ECF23, 2022, 42 : 1668 - 1675
  • [3] Fire Protection of CFRP-strengthened RC Structures
    Turkowski, Piotr
    Sulik, Pawel
    RESPONSE OF STRUCTURES UNDER EXTREME LOADING, 2015, : 789 - 796
  • [4] Numerical Modeling and Design of CFRP-Strengthened Short Steel Tubular Columns in Fire
    Imran, Mohamed
    Mahendran, Mahen
    JOURNAL OF STRUCTURAL ENGINEERING, 2021, 147 (04)
  • [5] New materials for fire-resistant batteries
    Jacoby, Mitch
    CHEMICAL & ENGINEERING NEWS, 2016, 94 (45) : 30 - 32
  • [6] THE USE OF PHOSPHAZENES AS FIRE-RESISTANT MATERIALS
    ALLEN, CW
    JOURNAL OF FIRE SCIENCES, 1993, 11 (04) : 320 - 328
  • [7] TESTING PROCEDURES FOR FIRE-RESISTANT MATERIALS
    BOSSERT, JA
    CIM BULLETIN, 1982, 75 (846): : 57 - 61
  • [8] FIRE-RESISTANT FLUID PERFORMANCE OPTIMIZATION
    SKUCE, DR
    CIM BULLETIN, 1984, 77 (867): : 27 - 27
  • [9] Fire protection thickness of concrete-filled fire-resistant steel tubular columns
    Liu, Yi-Xiang
    Tong, Gen-Shu
    Zhang, Lei
    Zhejiang Daxue Xuebao (Gongxue Ban)/Journal of Zhejiang University (Engineering Science), 2015, 49 (12): : 2387 - 2396
  • [10] Evaluation of feasibility and performance of foamed Fire-Resistant coating materials
    Zhu, Anyou
    Wu, Hanli
    Wang, Yizhuang David
    Liu, Jenny
    CONSTRUCTION AND BUILDING MATERIALS, 2023, 400