Accuracy in navigated percutaneous sacroiliac screw fixation: a systematic review and meta-analysis

被引:0
作者
Haveman, R. A. [1 ,2 ]
Buchmann, L. [1 ]
Haefeli, P. C. [1 ]
Beeres, F. J. P. [1 ,2 ]
Babst, R. [1 ,2 ]
Link, B. - C. [1 ]
van de Wall, B. J. M. [1 ,2 ]
机构
[1] Cantonal Hosp Lucerne, Orthopaed & Traumatol Dept, Luzern, Switzerland
[2] Univ Lucerne, Fac Hlth Sci & Med, Luzern, Switzerland
关键词
Sacroiliac screws; Accuracy; Navigation; Radiation; POSTERIOR PELVIC RING; ILIOSACRAL SCREWS; FLUOROSCOPY; PLACEMENT; FRACTURES; COMPLICATIONS; INSERTION; SURGERY; REDUCE;
D O I
10.1186/s12893-025-02813-z
中图分类号
R61 [外科手术学];
学科分类号
摘要
IntroductionPercutaneous sacroiliac screw fixation of pelvic fragility fractures is increasingly being used to maintain mobility and reduce pain in the elderly patient population. Traditionally, this is performed using 2D fluoroscopy. Several newer, navigated techniques have emerged that may further facilitate this procedure. It, however, remains unclear whether there is a benefit regarding accuracy, radiation exposure and complications of these new navigation techniques when compared to the traditional 2D fluoroscopy.MethodsA systematic review and meta-analysis were performed. PubMed, CENTRAL and Embase were searched for both randomized controlled trials and observational studies comparing new navigation techniques to 2D fluoroscopy for percutaneous sacroiliac screw fixation. Effect estimates were pooled (random effects) and presented as odds ratio, mean difference and standardized mean difference with a 95% confidence interval.Results19 studies were included. The 2D fluoroscopy group had 642 patients and the new navigation group 663 patients. Accuracy was significantly higher in the new navigation group (OR 2.44, 95% CI 1.53-3.90), especially O-Arm, 3D CT and Robotic navigation. On average, accuracy was 82% in the 2D group and 92% in the new navigation group, which was significant. Also, fluoroscopy time (MD 71.89 s, 95% CI 51.37-92.41) and frequency (MD 17.22 images in total, 95% CI 7.73-26.70) were significantly reduced in the new navigation group. Complications are acceptably low, however, poorly reported in both groups.ConclusionThis meta-analysis demonstrated a higher accuracy, lower fluoroscopic frequency and time for new navigation techniques compared to 2D fluoroscopy. More advanced navigation techniques, such as 3D CT and robotic navigation, appeared to be even better.
引用
收藏
页数:10
相关论文
共 43 条
  • [41] Percutaneous Sacroiliac Screw Placement: A Prospective Randomized Comparison of Robot-assisted Navigation Procedures with a Conventional Technique
    Wang, Jun-Qiang
    Wang, Yu
    Feng, Yun
    Han, Wei
    Su, Yong-Gang
    Liu, Wen-Yong
    Zhang, Wei-Jun
    Wu, Xin-Bao
    Wang, Man-Yi
    Fan, Yu-Bo
    [J]. CHINESE MEDICAL JOURNAL, 2017, 130 (21) : 2527 - 2534
  • [42] Preoperative CT simulation of iliosacral screws for treating unstable posterior pelvic ring injury
    Zhao, Peishuai
    Wang, Xiaopan
    Chen, Xiaotian
    Guan, Jianzhong
    Wu, Min
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [43] Intra- and postoperative complications of navigated and conventional techniques in percutaneous iliosacral screw fixation after pelvic fractures: Results from the German Pelvic Trauma Registry
    Zwingmann, Joern
    Suedkamp, Norbert P.
    Koenig, Benjamin
    Culemann, Ulf
    Pohlemann, Tim
    Aghayev, Emin
    Schmal, Hagen
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (12): : 1765 - 1772