Determining anatomically-safe corridors for placement of lateral mass screws in the first cervical vertebra of the Emirati population - a CT study

被引:0
作者
Suresh, Dineshwary [1 ]
Naidoo, Nerissa [1 ]
Alsharhan, Rashid [1 ]
Al Bastaki, Usama [2 ]
Lakshmanan, Jeyaseelan [1 ]
Joseph, Baylis Vivek [3 ]
Prithishkumar, Ivan James [1 ]
机构
[1] Mohammed Bin Rashid Univ Med & Hlth Sci, Dubai Hlth, Coll Med, Dubai, U Arab Emirates
[2] Rashid Hosp, Dubai Hlth, Diagnost Imaging, Dubai, U Arab Emirates
[3] Christian Med Coll & Hosp, Neurosurg, Vellore, India
关键词
Cervical; Vertebra; Atlas; Lateral mass; Screw; Emirati; OPTIMAL ENTRY POINT; C2 NERVE ROOT; POSTERIOR ARCH; TECHNICAL NOTE; FIXATION; ATLAS; INSERTION; ANATOMY; PLATE;
D O I
10.1038/s41598-025-85181-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The first cervical vertebra (C1) is atypical in shape and bears a complex relationship with important neurovascular structures such as the vertebral artery and cervical spinal cord which are at risk of injury during misplaced screw fixation of C1. Placement of screws into the lateral mass of C1 vertebra is performed for stabilization of the craniovertebral junction. The objective of this study was to describe ideal screw dimensions, precise entry points, safe bony corridors, and ideal trajectories for placement of lateral mass screws in the Emirati population. CT scans of 160 Emirati patients (> 18 years) were studied and variables relevant to lateral mass screw fixation were measured. Screw entry at the centre of lateral mass, below its junction with the posterior arch, allowed straight screws of lengths of 20 mm and 19.5 mm in Emirati males and females, respectively. A medial angulation of 20 degrees in males and 15 degrees in females allowed maximum bone purchase. Screw entry at the junction of medial margin of posterior arch and lateral mass allowed straight screws of length 18 mm in both males and females. We recommend safe cephalic angulations of 19 degrees and 16 degrees in males and females, respectively. The mean critical width was 7.6 mm in males and 6.8 mm in females which would safely permit screws of width 4.0 mm. Pre-operative knowledge of the above dimensions would help in greater precision, minimizing the risk of injury to neurovascular structures in the vicinity of C1 lateral mass.
引用
收藏
页数:11
相关论文
共 28 条
[21]   C1 Lateral Mass Anatomy Proper Placement of Lateral Mass Screws [J].
Seal, Charles ;
Zarro, Christopher ;
Gelb, Daniel ;
Ludwig, Steven .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2009, 22 (07) :516-523
[22]  
Senoglu M, 2017, Journal of Clinical Neuroscience, V2017
[23]  
Singla M, 2015, J Clin Diagn Res., VAC04-9
[24]   Morphometric evaluation of screw fixation in atlas via posterior arch and lateral mass [J].
Tan, MS ;
Wang, HM ;
Wang, YT ;
Zhang, GB ;
Yi, P ;
Li, ZR ;
Wei, HY ;
Yang, F .
SPINE, 2003, 28 (09) :888-895
[25]   C1 lateral mass screw insertion caudally from C2 nerve root - An alternate method for insertion of C1 screws: A technical note and preliminary clinical results [J].
Wada, Keiji ;
Tamaki, Ryo ;
Yui, Mitsuru ;
Numaguchi, Daisuke ;
Murata, Yasuaki .
JOURNAL OF ORTHOPAEDIC SCIENCE, 2017, 22 (02) :213-217
[26]   Journal Club: C2 Nerve Root Transection During C1 Lateral Mass Screw Fixation: Does It Affect Functionality and Quality of Life? [J].
Witiw, Christopher D. ;
Mansouri, Alireza ;
Badhiwala, Jetan H. ;
Nassiri, Farshad .
NEUROSURGERY, 2015, 76 (05) :638-640
[27]   Posterior screw placement on the lateral mass of atlas - An anatomic study [J].
Xia, H ;
Yin, D ;
Chang, YB ;
Yin, QS ;
Zhong, SZ ;
Liu, JF .
SPINE, 2004, 29 (05) :500-503
[28]  
Yuwakosol Pakorn, 2022, Asian J Neurosurg, V17, P429, DOI 10.1055/s-0042-1756625