Performance of Hollow-Core Photonic Crystal Fiber-Based Trace C2H2 Detection System

被引:1
|
作者
Chao, Xianzong [1 ]
Zeng, Fuping [2 ,3 ]
Cheng, Hongtu [4 ]
Jiang, Xinghai [1 ]
Huang, Zujian [1 ]
Yao, Qiang [5 ]
Tang, Ju [2 ,3 ]
机构
[1] Wuhan Univ, Sch Elect Engn & Automat, Wuhan 430072, Peoples R China
[2] Wuhan Univ, Sch Elect Engn & Automat, Wuhan 430072, Peoples R China
[3] Wuhan Univ, Hubei Key Lab Power Equipment & Syst Secur Integra, Wuhan 430072, Peoples R China
[4] Nanjing Tech Univ, Coll Elect Engn & Control Sci, Nanjing 211816, Peoples R China
[5] State Grid Chongqing Elect Power Co, Elect Power Res Inst, Chongqing 401123, Peoples R China
基金
中国国家自然科学基金;
关键词
Optical fibers; Optical fiber sensors; Frequency modulation; Uncertainty; Absorption; Photonic crystals; Attenuation; Sensor systems; Optical modulation; Standards; Direct absorption spectroscopy (DAS); gas detection; hollow-core photonic crystal fiber (HC-PCF); measurement uncertainty; performance analysis; SPECTROSCOPY;
D O I
10.1109/TIM.2025.3534217
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this article, we propose an optical sensor system utilizing the capabilities of hollow-core photonic crystal fiber (HC-PCF) to transmit excitation light and hold sample gas. The direct absorption response is examined for different modulation waveforms, pressures, frequencies, and concentrations. The experimental results show that the response signal has an obvious overshoot and spike. The overshoot and spike are more obvious under the sine modulation than the rectangular modulation. In the 1-500-Hz range, the system demonstrated optimum response characteristics at 5 Hz, corresponding to the maximum attenuation percentage. Furthermore, a positive correlation was observed between the attenuation percentage of light intensity (A(t)) and optical power (A(p)) with the pressure in the gas chamber within the range of 0.1-0.3 MPa. When the gas chamber is filled with 10000-ppm C2H2/N-2 to 0.3 MPa, At and Ap are 47.98% and 22.73%, respectively. A good linear relationship exists between the attenuation value of photodetector (PD) output and target gas concentration with a correlation coefficient above 0.99 after 140 s. The theoretical minimum detection limit of C2H2 without the erbium-doped fiber amplifier (EDFA) is 49.28 ppm and the relative synthetic standard uncertainty is 3.35%. This article provides an idea for applying the HC-PCF-based gas sensing system.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] The Structural Defects and Optical Performance of Polarization-Maintaining Hollow-Core Photonic Bandgap fiber
    Wang, Lidong
    Liao, Meisong
    Yu, Fei
    Chen, Liang
    Wang, Yazhou
    Wu, Dakun
    Wang, Tianxing
    Hu, Lili
    Gao, Weiqing
    IEEE PHOTONICS JOURNAL, 2023, 15 (03):
  • [22] Possibility of Comparison of the Similar Pharmaceuticals from Different Producers by Spectroscopic System Based on Hollow-Core Photonic-Crystal Fiber
    K. A. Bzheumikhov
    Z. Ch. Margushev
    Yu. V. Savoiskii
    Journal of Analytical Chemistry, 2018, 73 : 344 - 350
  • [23] Accelerometer based on all-fiber Fabry-Perot interferometer formed by hollow-core photonic crystal fiber
    Ke T.
    Zhu T.
    Rao Y.
    Xu M.
    Shi C.
    Zhongguo Jiguang/Chinese Journal of Lasers, 2010, 37 (01): : 171 - 175
  • [24] ACCELEROMETER BASED ON ALL-FIBER FABRY-PEROT INTERFEROMETER FORMED BY HOLLOW-CORE PHOTONIC CRYSTAL FIBER
    Ke, Tao
    Zhu, Tao
    Rao, Yunjiang
    Deng, Ming
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2010, 52 (11) : 2531 - 2535
  • [25] Experimental Study of Hollow-Core Photonic Crystal Fiber Optical Switching Effect in Liquid Nitrogen Environment
    Song, Ningfang
    Zhu, Yunhao
    Xu, Xiaobin
    Xu, Shijie
    Gao, Fuyu
    IEEE PHOTONICS JOURNAL, 2020, 12 (03):
  • [26] Possibility of Comparison of the Similar Pharmaceuticals from Different Producers by Spectroscopic System Based on Hollow-Core Photonic-Crystal Fiber
    Bzheumikhov, K. A.
    Margushev, Z. Ch.
    Savoiskii, Yu. V.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 73 (04) : 344 - 350
  • [27] Analysis of CH4, C2H6, C2H4, C2H2, H2, CO, and H2S by forward Raman scattering with a hollow-core anti-resonant fiber
    Bai, Yusi
    Xiong, Dongsheng
    Yao, Zhongyi
    Wang, Xinbing
    Zuo, Duluo
    JOURNAL OF RAMAN SPECTROSCOPY, 2022, 53 (05) : 1023 - 1031
  • [28] Portable Acetylene Frequency References inside Sealed Hollow-core Kagome Photonic Crystal Fiber
    Wang, Chenchen
    Wheeler, Natalie V.
    Lim, Jinkang
    Knabe, Kevin
    Grogan, Michael
    Wang, Yingying
    Washburn, Brian R.
    Benabid, Fetah
    Corwin, Kristan L.
    2011 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2011,
  • [29] Transient quantum coherent effects in the acetylene-filled hollow-core photonic crystal fiber
    Stepanov, S.
    Rodriguez Casillas, N.
    Ocegueda Miramontes, M.
    Hernandez Hernandez, E.
    SLOW LIGHT, FAST LIGHT, AND OPTO- ATOMIC PRECISION METROLOGY X, 2017, 10119
  • [30] Theoretical Analysis of a Molecular Optical Modulator for a Continuous-Wave Laser Based on a Hollow-Core Photonic Crystal Fiber
    Zaitsu, Shin-ichi
    Tanabe, Takumi
    Oshima, Kota
    Hirata, Hiroyuki