Determining the Total Ozone Column from Spectral Measurements of IKFS-2 in 2015-2022

被引:0
作者
Polyakov, A. V. [1 ]
Kriukovskikh, E. P. [1 ]
Virolainen, Ya. A. [1 ]
Nerobelov, G. M. [1 ,2 ,3 ]
Kozlov, D. A. [4 ]
Timofeyev, Yu. M. [1 ]
机构
[1] St Petersburg Univ, St Petersburg 199034, Russia
[2] Russian Acad Sci, Sci Res Ctr Ecol Safety, St Petersburg 187110, Russia
[3] Russian State Hydrometeorol Univ, St Petersburg 195196, Russia
[4] Keldysh Res Ctr, Moscow 125438, Russia
关键词
remote sensing of the atmosphere; atmospheric ozone; IKFS-2; ozone total column; ATMOSPHERIC COMPOSITION; SATELLITE; VALIDATION;
D O I
10.1134/S0001433824700713
中图分类号
P4 [大气科学(气象学)];
学科分类号
0706 ; 070601 ;
摘要
The results of determining the ozone total column (OTC) from the spectra of the outgoing thermal infrared radiation measured by the IKFS-2 instrument from the Meteor-M No. 2 spacecraft during 8 years of measurements are presented. The previously developed technique for the interpretation of spectral measurements made in 2015-2020 with a swath width (SW) of 1000 km is applied to the measurements in 2021-2022 with a SW of 1500 km. It is shown that the increase in the differences between the IKFS-2 data and the results of independent measurements is caused not by the expansion of the OTC variability statistics, but by the increase in the range of scanning angle variation. After a finalization of the technique for the measurements with a 1500-km SW, a comparison with independent data showed that the standard deviations of differences with the results of ground and satellite measurements for all 8 years do not exceed 3% and did not increase compared to the first 6 years of measurements. To analyze the results in the polar regions, the OTC values obtained from the IKFS-2 spectra are compared with the ozonesonde data, which are performed continuously throughout the year, including the polar night. A good qualitative agreement of the IKFS-2 data and ozone sounding data, including winter-spring periods of extreme OTC decrease at high latitudes of both hemispheres, is shown. The standard deviations of the differences between the IKFS-2 data and the OTC values from ozone sounding data were from 5.3 to 11% (17-33 DU) for different stations, or on average for all stations 7.9%, which is consistent with the uncertainty of the estimates of the integrated ozone content in the vertical column from ozonesonde data.
引用
收藏
页码:689 / 698
页数:10
相关论文
共 27 条
  • [1] Andreev V.V., Bazhenov O.E., Belan B.D., Vargin P.N., Gruzdev A.N., Elansky N.F., Zhamsueva G.S., Zayakhanov A.S., Kotel'nikov S.N., Kuznetsova I.N., Kulikov M., Nevzorov A.V., Obolkin V.A., Postylyakov O.V., Rozanov E.V., Russian Studies of Atmospheric Ozone and Its Precursors in 2019–2022, Izv., Atmos. Ocean. Phys, 59, pp. S437-S461, (2023)
  • [2] Bernath P.F., The Atmospheric Chemistry Experiment (ACE), J. Quant. Spectrosc. Radiat. Transfer, 186, pp. 3-16, (2017)
  • [3] Bertaux J.L., Megie G., Widemann T., Chassefiere E., Pellinen R., Kyrola E., Korpela S., Simon P., Monitoring of ozone trend by stellar occultations: The GOMOS instrument, Adv. Space Res, 11, pp. 237-242, (1991)
  • [4] Boynard A., Hurtmans D., Koukouli M.E., Goutail F., Bureau J., Safieddine S., Lerot C., Hadji-Lazaro J., Wespes C., Pommereau J.-P., Seven years of IASI ozone retrievals from FORLI: Validation with independent total column and vertical profile measurements, Atmos. Meas. Tech, 9, pp. 4327-4353, (2016)
  • [5] Clerbaux C., Boynard A., Clarisse L., George M., Hadji-Lazaro J., Herbin H., Hurtmans D., Pommier M., Razavi A., Turquety S., Wespes C., Coheur P.-F., Monitoring of atmospheric composition using the thermal infrared IASI/MetOp sounder, Atmos. Chem. Phys, 9, pp. 6041-6054, (2009)
  • [6] Garane K., Koukouli M.-E., Verhoelst T., Lerot C., Heue K.-P., Fioletov V., Balis D., Bais A., Bazureau A., Dehn A., TROPOMI/S5P total ozone column data: Global ground- based validation and consistency with other satellite missions, Atmos. Meas. Tech, 12, pp. 5263-5287, (2019)
  • [7] Garkusha A.S., Polyakov A.V., Timofeev Y., Virolainen Y., Analysis of capabilities for satellite monitoring of atmospheric gaseous composition using IRFS-2 instrument, Izv., Atmos. Ocean. Phys, 53, pp. 493-501, (2017)
  • [8] (2014)
  • [9] Glatthor N., von Clarmann T., Fischer H., Funke B., Gil-Lopez S., Grabowski U., Hopfner M., Kellmann S., Linden A., Lopez-Puertas M., Mengistu Tsidu G., Milz M., Steck T., Stiller G.P., Wang D.-Y., Retrieval of stratospheric ozone profiles from MIPAS/ENVISAT limb emission spectra: A sensitivity study, Atmos. Chem. Phys, 6, pp. 2767-2781, (2006)
  • [10] Golovin Y.M., Zavelevich F.S., Nikulin A.G., Kozlov D.A., Monakhov D.O., Kozlov I.A., Arkhipov S.A., Tselikov V.A., Romanovskii A.S., Spaceborne infrared Fourier-transform spectrometers for temperature and humidity sounding of the Earth’s atmosphere, Izv., Atmos. Ocean. Phys, 50, pp. 1004-1015, (2014)