Effect of cobalt ions doping on morphology and electrochemical properties of hydroxyapatite coatings for biomedical applications

被引:6
作者
Safari-Gezaz, Meysam [1 ]
Parhizkar, Mojtaba [1 ]
Asghari, Elnaz [2 ]
机构
[1] Univ Tabriz, Fac Phys, Dept Condensed Matter Phys, 29 Bahman Blvd, Tabriz, Iran
[2] Univ Tabriz, Fac Chem, Dept Phys Chem, 29 Bahman Blvd, Tabriz, Iran
来源
SCIENTIFIC REPORTS | 2025年 / 15卷 / 01期
关键词
Hydroxyapatite; Co2+; Spin-coating; Corrosion; SBF; Biomedical; IN-VITRO; IMPLANT MATERIALS; TITANIUM-ALLOYS; DOPED HYDROXYAPATITE; OSSEOINTEGRATION; BIOCOMPATIBILITY; TI-6AL-4V; COMPOSITE; BEHAVIOR;
D O I
10.1038/s41598-024-84055-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Hydroxyapatite (HA) is an engineered biomaterial that closely resembles the hard tissue composition of humans. Biological HA is commonly non-stoichiometric and features lower crystallinity and higher solubility than stoichiometric HA. The chemical compositions of these biomaterials include calcium (Ca), phosphorus (P), and trace amounts of various ions such as magnesium (Mg2+), zinc (Zn2+), and strontium (Sr2+). Significantly, these ions are essential for the metabolic processes of hard tissues. This study involved the application of Co2+-doped HA coatings at different concentrations (5%, 10%, and 20% by weight) onto Ti-6Al-4V, utilizing the spin-coating method. The FTIR, XRD, FESEM, EDS, and AFM techniques were utilized to analyze the coated substrates. Tetraethyl orthosilicate (TEOS (T)) was employed as a binding agent to enhance adhesion and reduce surface cracks in the coating. The adhesion strength of coatings applied to Ti-6Al-4V was assessed for use in biomedical applications. Polarization and electrochemical impedance spectroscopy (EIS) studies in a simulated body fluid (SBF) solution were conducted to evaluate the corrosion behavior of the coatings. The corrosion behavior of the coated samples increased significantly compared to the substrate. The 10Co/HA/T coating demonstrated the highest charge transfer resistance (R-ct) value of 13.40 M Omega x cm(2), whereas the uncoated substrate exhibited the lowest R-ct of 0.14 M Omega x cm(2). A cell viability assay was conducted utilizing MG-63 cells for the Ti-6Al-4V and coatings, which prepared coatings demonstrated outstanding biocompatibility. Based on this study, the 10Co/HA/T coating was identified as the most promising sample. These findings suggest that surface modification of Ti-6Al-4V through Co2+-doped HA coatings offers a viable strategy for enhancing its performance in biomedical applications.
引用
收藏
页数:20
相关论文
共 86 条
[1]   Modification of hydroxyapatite-based coating in the presence of polyvinylalcohol (PVA) for implant application: Corrosion, structure and surface study [J].
Afshari, M. ;
Mohammadloo, H. Eivaz ;
Sarabi, A. A. ;
Roshan, Sh. .
CORROSION SCIENCE, 2021, 192 (192)
[2]   Bactericidal and in vitro osteogenic activity of nano sized cobalt-doped silicate hydroxyapatite [J].
Alshemary, Ammar Z. ;
Hussain, Rafaqat ;
Dalgic, Ali Deniz ;
Evis, Zafer .
CERAMICS INTERNATIONAL, 2022, 48 (19) :28231-28239
[3]  
Anjaneyulu U., 2014, INT J CHEMTECH RES, V7, P1516
[4]   Material processing of hydroxyapatite and titanium alloy (HA/Ti) composite as implant materials using powder metallurgy: A review [J].
Arifin, Amir ;
Sulong, Abu Bakar ;
Muhamad, Norhamidi ;
Syarif, Junaidi ;
Ramli, Mohd Ikram .
MATERIALS & DESIGN, 2014, 55 :165-175
[5]   Studying the Effect of Cobalt Doping on Optical and Magnetic Properties of Zinc Oxide Nanoparticles [J].
Azab, A. A. ;
Esmail, S. A. ;
Abdelamksoud, M. K. .
SILICON, 2019, 11 (01) :165-174
[6]   Evaluation of in vitro and in vivo biocompatibility and structure of cobalt releasing sol-gel bioactive glass [J].
Barrioni, Breno Rocha ;
Santos de Laia, Andreia Grossi ;
Valverde, Thalita Marcolan ;
da Mata Martins, Thais Maria ;
Caliari, Marcelo Vidigal ;
de Sa, Marcos Augusto ;
de Goes, Alfredo Miranda ;
Pereira, Marivalda de Magalhaes .
CERAMICS INTERNATIONAL, 2018, 44 (16) :20337-20347
[7]   Antibacterial and magnetic response of site-specific cobalt incorporated hydroxyapatite [J].
Bhattacharjee, Arjak ;
Gupta, Anshul ;
Verma, Madhu ;
Anand, Murugan Prem ;
Sengupta, Pradyut ;
Saravanan, Matheshwaran ;
Manna, Indranil ;
Balani, Kantesh .
CERAMICS INTERNATIONAL, 2020, 46 (01) :513-522
[8]   VIBRATIONAL SPECTRA OF HYDROTHERMALLY PREPARED HYDROXYAPATITES [J].
BLAKESLEE, KC ;
CONDRATE, RA .
JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 1971, 54 (11) :559-+
[9]   Plasma in dentistry [J].
Cha, Seunghee ;
Park, Young-Seok .
CLINICAL PLASMA MEDICINE, 2014, 2 (01) :4-10
[10]   Corrosion inhibition potential of 2-[(5-methylpyrazol-3-yl)methyl] benzimidazole against carbon steel corrosion in 1 M HCl solution: Combining experimental and theoretical studies [J].
Chkirate, Karim ;
Azgaou, Karim ;
Elmsellem, Hicham ;
El Ibrahimi, Brahim ;
Sebbar, Nada Kheira ;
Anouar, El Hassane ;
Benmessaoud, Mohammed ;
El Hajjaji, Souad ;
Essassi, El Mokhtar .
JOURNAL OF MOLECULAR LIQUIDS, 2021, 321