Recent Advancements in Cardiac Implantable Devices for Pediatric Patients

被引:0
作者
Kumthekar, Rohan N. [1 ,2 ]
Howard, Taylor S. [3 ]
机构
[1] Nationwide Childrens Hosp, Div Cardiol, 700 Childrens Dr, Columbus, OH 43205 USA
[2] Ohio State Univ, Dept Pediat, Coll Med, 370 W 9th Ave, Columbus, OH 43210 USA
[3] Texas Childrens Hosp, Baylor Coll Med, Dept Pediat, Div Pediat Cardiol, Houston, TX USA
关键词
Pediatric; Pacemaker; ICD; Epicardial; HEART-DISEASE PATIENTS; CARDIOVERTER-DEFIBRILLATORS; HIS-BUNDLE; EPICARDIAL PACEMAKER; PRIMARY PREVENTION; YOUNG-ADULTS; CHILDREN; PERMANENT; THERAPY; PERFORMANCE;
D O I
10.1007/s40124-024-00334-6
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Purpose of ReviewWe highlight recent advances in cardiac implantable electronic devices (CIEDs) that are applicable and can be beneficial for pediatric patients.Recent FindingsProgress in pacemakers includes the widespread use of leadless pacemakers, development of tools for left bundle area pacing, and the design of novel miniaturized pacemakers and minimally invasive approaches for epicardial device implantation. For implantable cardioverter defibrillators (ICDs), there has been more utilization of the subcutaneous ICD in smaller patients or those with congenital heart disease, and significant improvements in ICD programming as well.SummaryLeadless pacemakers have been safely utilized in children, even those under 30 kg with acute and medium-term success. Left bundle area pacing may provide a reduction in pacing-induced cardiomyopathy in the future. Novel miniature pacemakers and approaches to epicardial lead implantation can reduce complications for our smallest patients. Subcutaneous ICDs have been used effectively in the pediatric cohort with similar results to the adult population. ICD programming has been improved to reduce the risk of inappropriate shocks.
引用
收藏
页码:147 / 157
页数:11
相关论文
共 77 条
[1]   EWOLUTION-The next evolution in appendage closure? [J].
Afzal, Muhammad R. ;
Daoud, Emile G. .
HEART RHYTHM, 2017, 14 (09) :1309-1310
[2]   Multi-Institutional Study of Implantable Defibrillator Lead Performance in Children and Young Adults: Results of the Pediatric Lead Extractability and Survival Evaluation (PLEASE) Study [J].
Atallah, Joseph ;
Erickson, Christopher C. ;
Cecchin, Frank ;
Dubin, Anne M. ;
Law, Ian H. ;
Cohen, Mitchell I. ;
LaPage, Martin J. ;
Cannon, Bryan C. ;
Chun, Terrence U. H. ;
Freedenberg, Vicki ;
Gierdalski, Marcin ;
Berul, Charles I. .
CIRCULATION, 2013, 127 (24) :2393-2402
[3]   Retrieval of Chronically Implanted Dual-chamber Leadless Pacemakers in an Ovine Model [J].
Banker, Rajesh S. ;
Rippy, Marian K. ;
Cooper, Nicole ;
Neuzil, Petr ;
Exner, Derek V. ;
Nair, Devi G. ;
Booth, Daniel F. ;
Ligon, David ;
Badie, Nima ;
Krans, Mark ;
Ando, Kenji ;
Knops, Reinoud E. ;
Ip, James E. ;
Doshi, Rahul N. ;
Rashtian, Mayer ;
Reddy, Vivek Y. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2023, 16 (10) :E012232
[4]   Congenital and childhood atrioventricular blocks: pathophysiology and contemporary management [J].
Baruteau, Alban-Elouen ;
Pass, Robert H. ;
Thambo, Jean-Benoit ;
Behaghel, Albin ;
Le Pennec, Solene ;
Perdreau, Elodie ;
Combes, Nicolas ;
Liberman, Leonardo ;
McLeod, Christopher J. .
EUROPEAN JOURNAL OF PEDIATRICS, 2016, 175 (09) :1235-1248
[5]   Results of a multicenter retrospective implantable cardioverter-defibrillator registry of pediatric and congenital heart disease patients [J].
Berul, Charles I. ;
Van Hare, George F. ;
Kertesz, Naomi J. ;
Dubin, Anne M. ;
Cecchin, Frank ;
Collins, Kathryn K. ;
Cannon, Bryan C. ;
Alexander, Mark E. ;
Triedman, John K. ;
Walsh, Edward P. ;
Friedman, Richard A. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (17) :1685-1691
[6]   Tiny pacemakers for tiny babies [J].
Berul, Charles I. ;
Dasgupta, Soham ;
LeGras, Marc D. ;
Peer, S. Murfad ;
Sherwin, Elizabeth D. ;
Alsoufi, Bahaaldin ;
Desai, Manan ;
Yerebakan, Can ;
Johnsrude, Christopher .
HEART RHYTHM, 2023, 20 (05) :766-769
[7]   Minimally invasive Cardioverter defibrillator implantation for children: An animal model and pediatric case report [J].
Berul, CI ;
Triedman, JK ;
Forbess, J ;
Bevilacqua, LM ;
Alexander, ME ;
Dahlby, D ;
Gilkerson, JO ;
Walsh, EP .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (12) :1789-1794
[8]   Selecting the right defibrillator in the younger patient: Transvenous, epicardial or subcutaneous? [J].
Bogush, Nikolay ;
Espinosa, Raul E. ;
Cannon, Bryan C. ;
Wackel, Philip L. ;
Okamura, Hideo ;
Friedman, Paul A. ;
McLeod, Christopher J. .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 250 :133-138
[9]   Early Performance and Safety of the Micra Transcatheter Pacemaker in Pigs [J].
Bonner, Matthew ;
Eggen, Michael ;
Haddad, Tarek ;
Sheldon, Todd ;
Williams, Eric .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2015, 38 (11) :1248-1259
[10]   Long-Term Clinical Outcomes of Subcutaneous Versus Transvenous Implantable Defibrillator Therapy [J].
Brouwer, Tom F. ;
Yilmaz, Dilek ;
Lindeboom, Robert ;
Buiten, Maurits S. ;
Nordkamp, Louise R. A. Olde ;
Schalij, Martin J. ;
Wilde, Arthur A. ;
van Erven, Lieselot ;
Knops, Reinoud E. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (19) :2047-2055