Touchscreen-based assessment of upper limb kinematics after stroke: Reliability, validity and sensitivity to motor impairment

被引:1
作者
Goizueta, Sandra [1 ]
Dolores Navarro, Maria [2 ]
Calvo, Gabriela [1 ]
Campos, Gloria [1 ]
Colomer, Carolina [2 ]
Noe, Enrique [2 ]
Llorens, Roberto [1 ]
机构
[1] Univ Politecn Valencia, Neurorehabil & Brain Res Grp, Inst Human Ctr Technol Res, Ciudad Politecn Innovac, Bldg 8B,Access M,Floor 0,Camino de Vera S-N, Valencia 46022, Spain
[2] Fdn Vithas, IRENEA, Inst Rehabil Neurol, Valencia, Spain
关键词
Stroke; Upper limb; Kinematic assessment; Touchscreen technology; Reliability; Convergent validity; Sensitivity; MINIMAL DETECTABLE CHANGE; TEST-RETEST RELIABILITY; REACHING MOVEMENTS; ADULT NORMS; PEOPLE; ARM; RECOVERY; INDIVIDUALS; DEXTERITY; SCALES;
D O I
10.1186/s12984-025-01563-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
BackgroundConventional clinical tools for assessing upper limb motor function often lack the sensitivity and specificity needed to detect subtle changes in motor performance and may be subject to bias. Kinematic assessment offers a potential solution by providing objective, precise, and detailed data on movement quality. However, it is typically associated with high costs, complex equipment, time-consuming procedures, and the need for controlled environments, all of which limit its accessibility and practicality in clinical settings. This study aimed to evaluate the reliability, validity, and sensitivity of a low-cost, touchscreen-based kinematic assessment tool for measuring upper limb function in individuals post-stroke.MethodsSixty-four individuals with stroke participated in this study. Participants performed a visually guided reaching task on a large touch screen that consisted in reaching from a central target to five outer targets arranged in a circular pattern, each at a time, and then returning to the central target. Their motor function was assessed using the Fugl-Meyer Assessment for Upper Extremity, the Box and Block Test, and the Nine Hole Peg Test. Kinematic measures of the trajectories performed during the reaching task were extracted and analyzed for reliability, convergent validity with clinical assessments, and sensitivity to impairment severity.ResultsThe kinematic measures demonstrated good to excellent test-retest reliability, with intraclass correlation coefficients ranging from moderate to excellent. The convergent validity analysis revealed multiple significant correlations between the kinematic parameters and clinical assessments, particularly in tests requiring higher skill and precision, such as the Coordination and Speed subscale of the Fugl-Meyer Assessment for Upper Extremity and the Nine Hole Peg Test. Additionally, the touchscreen-based assessment was sensitive to the severity of motor impairment, as reflected by notable differences in the kinematic measures among participants with varying levels of upper limb function.ConclusionsThe touchscreen-based kinematic assessment offered an affordable yet reliable, valid, and sensitive alternative for evaluating upper limb kinematics in individuals with stroke, which could complement clinical assessments by offering additional insights into motor performance. Furthermore, its low cost, high speed, and ease of use make it a practical option for widespread clinical adoption.
引用
收藏
页数:13
相关论文
共 76 条
[1]   Kinematic Variables Quantifying Upper-Extremity Performance After Stroke During Reaching and Drinking From a Glass [J].
Alt Murphy, Margit ;
Willen, Carin ;
Sunnerhagen, Katharina S. .
NEUROREHABILITATION AND NEURAL REPAIR, 2011, 25 (01) :71-80
[2]   Validity and sensitivity of instrumented postural and gait assessment using low-cost devices in Parkinson's disease [J].
Alvarez, Ignacio ;
Latorre, Jorge ;
Aguilar, Miquel ;
Pastor, Pau ;
Llorens, Roberto .
JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2020, 17 (01)
[3]  
Anderson F., 2012, CHI EA 12 CHI 12 EXT, P2351, DOI DOI 10.1145/2212776.2223801
[4]  
Annett M, 2018, HEALTH CARE DELIVERY AND CLINICAL SCIENCE: CONCEPTS, METHODOLOGIES, TOOLS, AND APPLICATIONS, P791, DOI 10.4018/978-1-5225-3926-1.ch041
[5]   Validating the measurement of upper limb sensorimotor behavior utilizing a tablet in neurologically intact controls and individuals with chronic stroke [J].
Austin, Devin Sean ;
Dixon, Makenna J. ;
Tulimieri, Duncan Thibodeau ;
Cashaback, Joshua G. A. ;
Semrau, Jennifer A. .
JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2023, 20 (01)
[6]   Estimating upper-extremity function from kinematics in stroke patients following goal-oriented computer-based training [J].
Ballester, Belen Rubio ;
Antenucci, Fabrizio ;
Maier, Martina ;
Coolen, Anthony C. C. ;
Verschure, Paul F. M. J. .
JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2021, 18 (01)
[7]   A stroke recovery trial development framework: Consensus-based core recommendations from the Second Stroke Recovery and Rehabilitation Roundtable [J].
Bernhardt, Julie ;
Hayward, Kathryn S. ;
Dancause, Numa ;
Lannin, Natasha A. ;
Ward, Nick S. ;
Nudo, Randolph J. ;
Farrin, Amanda ;
Churilov, Leonid ;
Boyd, Lara A. ;
Jones, Theresa A. ;
Carmichael, S. Thomas ;
Corbett, Dale ;
Cramer, Steven C. .
INTERNATIONAL JOURNAL OF STROKE, 2019, 14 (08) :792-802
[8]   A Tablet-Based Tool for Accurate Measurement of Hand Proprioception After Stroke [J].
Block, Hannah J. ;
Mirdamadi, Jasmine L. ;
Ryckman, Sydney ;
Lynch, Anna K. ;
Wilson, Reid ;
Udayan, Divya ;
Massie, Crystal L. .
JOURNAL OF NEUROLOGIC PHYSICAL THERAPY, 2019, 43 (02) :106-116
[9]   Effects of robot therapy on upper body kinematics and arm function in persons post stroke: a pilot randomized controlled trial [J].
Carpinella, Ilaria ;
Lencioni, Tiziana ;
Bowman, Thomas ;
Bertoni, Rita ;
Turolla, Andrea ;
Ferrarin, Maurizio ;
Jonsdottir, Johanna .
JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2020, 17 (01)
[10]   Kinematic descriptions of upper limb function using simulated tasks in activities of daily living after stroke [J].
Chen, Yen-Wei ;
Liao, Wan-Wen ;
Chen, Chia-Ling ;
Wu, Ching-Yi .
HUMAN MOVEMENT SCIENCE, 2021, 79