Determination of optimal sedation depth in sleep endoscopy with bispectrometry and simultaneous polysomnography

被引:0
作者
Gunduz, Oznur [1 ]
Ozcan, Kursat Murat [1 ]
Kundi, Fatma Cemre Sazak [2 ]
Erkilic, Ezgi [3 ]
Firat, Selma [4 ]
机构
[1] Ankara Bilkent City Hosp, Dept Otorhinolaryngol, Ankara, Turkiye
[2] Ankara Yildirim Beyazit Univ, Ankara City Hosp, Dept Otorhinolaryngol, Ankara, Turkiye
[3] Ankara Yildirim Beyazit Univ, Ankara City Hosp, Dept Anesthesiol & Reanimat, Ankara, Turkiye
[4] Ataturk Chest Dis Thorac Surg Training & Res Hosp, Sleep Disorders Ctr, Ankara, Turkiye
关键词
Apnea; Endoscopy; Polysomnography; Sedation; Obstructive Sleep Apnea; Sleep Stages; PROPOFOL-INDUCED SLEEP; INDEX; APNEA;
D O I
10.1007/s00405-024-09194-8
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
ObjectiveIn this study, we aimed to evaluate the localization and configuration of vibration and obstruction in drug-induced sleep endoscopy(DISE) in obstructive sleep apnea patients and to investigate the optimal sedation depth.Materials and methodsThe study was conducted prospectively with 42 patients. After achieving sedation with intravenous anesthetic agents, simultaneous monitoring of the patient's bispectrometry (BIS), DISE and sleep testing with a type 2 polysomnography device were performed. DISE was performed using fentanyl and midazolam, followed by propofol administered with manually controlled infusion method. The recorded data were evaluated and subjected to statistical comparisons.ResultsIt was observed that as BIS values decreased, the frequency of decreased respiratory effort and desaturation increased. Central apneas were observed with BIS values below 65 and were found to increase with deeper sedation, while with BIS values above 70, all respiratory events were obstructive apneas, with retro-palatal obstruction being the most common. It was noted that vibration occurred in over 90% of patients within the BIS range of 60-70. It was decided that the optimal sedation depth for evaluating vibration and obstruction in sleep endoscopy was within the BIS range of 60-75.ConclusionAccording to the results of our study, as sedation depth increases, the frequency of central apnea and desaturation increases. In our study, the sedation depth within the BIS 60-75 range was found to be the most suitable range for evaluating obstructive apnea and snoring.
引用
收藏
页码:2141 / 2148
页数:8
相关论文
共 50 条
[41]   Bispectral index monitoring of sedation depth during endoscopy: a meta-analysis with trial sequential analysis of randomized controlled trials [J].
Zhang, Hao ;
Lu, Yan ;
Wang, Lei ;
Lv, Jin ;
Ma, Yuheng ;
Wang, Wei ;
Li, Guanhua ;
Li, Yongwang .
MINERVA ANESTESIOLOGICA, 2019, 85 (04) :412-432
[42]   Can Statistical Machine Learning Algorithms Help for Classification of Obstructive Sleep Apnea Severity to Optimal Utilization of Polysomnography Resources? [J].
Bozkurt, Selen ;
Bostanci, Asli ;
Turhan, Murat .
METHODS OF INFORMATION IN MEDICINE, 2017, 56 (04) :308-318
[43]   Incidence and risk factors of nocturnal penetrations and aspirations in patients with obstructive sleep apnea during drug-induced sedation endoscopy [J].
Vainer, Igor ;
Allon, Raviv ;
Shapira-Galitz, Yael ;
Strinkovsky, Lior ;
Toh, Song Tar ;
Loh, Shaun ;
Alkan, Uri .
JOURNAL OF SLEEP RESEARCH, 2025, 34 (01)
[44]   Drug-induced sedation endoscopy in surgically naive infants and children with obstructive sleep apnea: impact on treatment decision and outcome [J].
Boudewyns, A. ;
Saldien, V. ;
Van de Heyning, P. ;
Verhulst, S. .
SLEEP AND BREATHING, 2018, 22 (02) :503-510
[45]   Drug-induced sedation endoscopy in surgically naïve infants and children with obstructive sleep apnea: impact on treatment decision and outcome [J].
A. Boudewyns ;
V. Saldien ;
P. Van de Heyning ;
S. Verhulst .
Sleep and Breathing, 2018, 22 :503-510
[46]   The Use of Middle Latency Auditory Evoked Potentials (MLAEP) as Methodology for Evaluating Sedation Level in Propofol-Drug Induced Sleep Endoscopy (DISE) Procedure [J].
Arigliani, Michele ;
Toraldo, Domenico M. ;
Ciavolino, Enrico ;
Lattante, Caterina ;
Conte, Luana ;
Arima, Serena ;
Arigliani, Caterina ;
Palumbo, Antonio ;
De Benedetto, Michele .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (04) :1-12
[47]   Der Einfluss des Zeitpunktes der medikamenteninduzierten Schlafendoskopie auf die Ausprägung des Apnoe-Hypopnoe-Indexes in der PolysomnographieImpact of the timing of drug-induced sleep endoscopy on the apnea–hypopnea index during polysomnography [J].
Joachim T. Maurer ;
Merle Gasparic ;
Jamal Huseynov .
Somnologie, 2024, 28 (4) :261-267
[48]   Sympathetic Activity and Hypothalamo-Pituitary-Adrenal Axis Activity During Sleep in Post-Traumatic Stress Disorder: A Study Assessing Polysomnography with Simultaneous Blood Sampling [J].
van Liempt, Saskia ;
Arends, Johan ;
Cluitmans, Pierre ;
Kahn, Rene ;
Vermetten, Eric .
BIOLOGICAL PSYCHIATRY, 2013, 73 (09) :95S-95S
[49]   Sympathetic activity and hypothalamo-pituitary-adrenal axis activity during sleep in post-traumatic stress disorder: A study assessing polysomnography with simultaneous blood sampling [J].
van Liempt, Saskia ;
Arends, Johan ;
Cluitnnans, Pierre J. M. ;
Westenberg, Herman G. M. ;
Kahn, Rene S. ;
Vermetten, Eric .
PSYCHONEUROENDOCRINOLOGY, 2013, 38 (01) :155-165
[50]   Continuous Determination of the Optimal Bispectral Index Value Based on Cerebrovascular Reactivity in Moderate/Severe Traumatic Brain Injury: A Retrospective Observational Cohort Study of a Novel Individualized Sedation Target [J].
Froese, Logan ;
Gomez, Alwyn ;
Sainbhi, Amanjyot Singh ;
Batson, Carleen ;
Stein, Kevin ;
Alizadeh, Arsalan ;
Mendelson, Asher A. ;
Zeiler, Frederick A. .
CRITICAL CARE EXPLORATIONS, 2022, 4 (03) :E0656