Comparison between spectral-domain optical coherence tomography-based and partial coherence interferometry-based biometry

被引:0
作者
Ahn, So Min [1 ]
Kim, Young Ho [2 ]
Yun, Cheolmin [2 ]
Oh, Jaeryung [2 ]
机构
[1] Dongguk Univ, Ilsan Hosp, Dept Ophthalmol, Goyang, South Korea
[2] Korea Univ, Coll Med, Dept Ophthalmol, Seoul, South Korea
关键词
Axial length; Optical coherence tomography; Partial coherence interferometry; Correlation Chorioretinal disease; AXIAL LENGTH MEASUREMENTS; MACULAR EDEMA; EYE; ULTRASOUND; IOLMASTER; MEMBRANE;
D O I
10.1038/s41598-024-79679-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We compared axial length (AL) measurements using spectral-domain optical coherence tomography (SD-OCT)-based and partial coherence interferometry (PCI)-based biometry in eyes with various chorioretinal diseases. Medical records were retrospectively analyzed in 123 eyes from 73 patients who underwent AL measurements using SD-OCT and PCI. AL values were highly consistent by both measurements (ICC = 0.996 in SD-OCT and 0.995 in PCI-based biometry). The mean difference in AL between the two instruments was - 0.09 +/- 0.17 mm, which was significant (P < 0.001). There was a strong correlation between the measurements obtained using the two instruments (r = 0.982, P < 0.001). The 95% limits of agreement were - 0.43 to 0.25 mm, and the agreement of AL in the Bland-Altman analysis showed a difference. The difference in measurements was not associated with the difference in central retinal thickness (r = 0.033, P = 0.720). However, the presence of an epiretinal membrane affected the difference in measurements, unlike in other chorioretinal diseases (P = 0.014). SD-OCT-based biometry showed a good correlation with PCI-based biometry in the measurement of AL; however, the mean AL between the two instruments was significantly different. Therefore, AL measurements made using SD-OCT-based and PCI-based biometry are not interchangeable.
引用
收藏
页数:9
相关论文
共 36 条
[1]   Evaluation and comparison of the new swept source OCT-based IOLMaster 700 with the IOLMaster 500 [J].
Akman, Ahmet ;
Asena, Leyla ;
Gungor, Sirel Gur .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2016, 100 (09) :1201-1205
[2]  
[Anonymous], 1991, Ophthalmology, V98, P786
[3]   Distribution of axial length, anterior chamber depth, and corneal curvature in an aged population in South China [J].
Chen, Hui ;
Lin, Haotian ;
Lin, Zhuoling ;
Chen, Jingjing ;
Chen, Weirong .
BMC OPHTHALMOLOGY, 2016, 16
[4]   Partial coherence interferometry: A novel approach to biometry in cataract surgery [J].
Drexler, W ;
Findl, O ;
Menapace, R ;
Rainer, G ;
Vass, C ;
Hitzenberger, CK ;
Fercher, AF .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 126 (04) :524-534
[5]   Whole Eye Segment Imaging and Measurement With Dual-Channel Spectral-Domain OCT [J].
Fan, Shanhui ;
Sun, Yong ;
Yang, Xuan ;
Dai, Cuixia ;
Ren, Qiushi ;
Zheng, Haihua ;
Zhou, Chuanqing .
Ophthalmic Surgery Lasers & Imaging Retina, 2015, 46 (02) :186-194
[6]   Swept-source OCT reduces the risk of axial length measurement errors in eyes with cataract and epiretinal membranes [J].
Faraldi, Francesco ;
Lavia, Carlo Alessandro ;
Nassisi, Marco ;
Kilian, Raphael A. ;
Bacherini, Daniela ;
Rizzo, Stanislao .
PLOS ONE, 2021, 16 (09)
[7]   Distribution of Axial Length and Ocular Biometry Measured Using Partial Coherence Laser Interferometry (IOL Master) in an Older White Population [J].
Fotedar, Reena ;
Wang, Jie Jin ;
Burlutsky, George ;
Morgan, Ian G. ;
Rose, Kathryn ;
Wong, Tien Y. ;
Mitchell, Paul .
OPHTHALMOLOGY, 2010, 117 (03) :417-423
[8]   Significance of Hyperreflective Foci as an Optical Coherence Tomography Biomarker in Retinal Diseases: Characterization and Clinical Implications [J].
Fragiotta, Serena ;
Abdolrahimzadeh, Solmaz ;
Dolz-Marco, Rosa ;
Sakurada, Yoichi ;
Gal-Or, Orly ;
Scuderi, Gianluca .
JOURNAL OF OPHTHALMOLOGY, 2021, 2021
[9]   Muller cells are living optical fibers in the vertebrate retina [J].
Franze, Kristian ;
Grosche, Jens ;
Skatchkov, Serguei N. ;
Schinkinger, Stefan ;
Foja, Christian ;
Schlid, Detlev ;
Uckermann, Ortrud ;
Travis, Kort ;
Reichenbach, Andreas ;
Guck, Jochen .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2007, 104 (20) :8287-8292
[10]   Correlations between ocular biometrics and refractive error: A systematic review and meta-analysis [J].
Gaurisankar, Zoraida S. ;
van Rijn, Gwyneth A. ;
Lima, Jose Eduardo E. ;
Ilgenfritz, Antonio P. ;
Cheng, Yanny ;
Haasnoot, Geert W. ;
Luyten, Gregorius P. M. ;
Beenakker, Jan-Willem M. .
ACTA OPHTHALMOLOGICA, 2019, 97 (08) :735-743