Comparison of cone-beam computed tomography with photon-counting detector computed tomography for dental implant surgery

被引:0
|
作者
Husain, Adib Al-Haj [1 ,2 ,3 ,4 ]
Mergen, Victor [5 ]
Valdec, Silvio [1 ]
Husain, Nadin Al-Haj [6 ]
Stadlinger, Bernd [1 ]
Essig, Harald [2 ]
Frauenfelder, Thomas [5 ]
Kessler, Peter [4 ]
Lie, Suen An Nynke [4 ]
Alkadhi, Hatem [5 ]
Winklhofer, Sebastian [3 ,7 ]
机构
[1] Univ Zurich, Ctr Dent Med, Clin Cranio Maxillofacial & Oral Surg, Plattenstr 11, CH-8032 Zurich, Switzerland
[2] Univ Zurich, Univ Hosp Zurich, Dept Cranio maxillofacial & Oral Surg, Zurich, Switzerland
[3] Univ Zurich, Univ Hosp Zurich, Clin Neurosci Ctr, Dept Neuroradiol, Zurich, Switzerland
[4] Maastricht Univ, GROW Sch Oncol & Reprod, Dept Cranio Maxillofacial Surg, Med Ctr, Maastricht, Netherlands
[5] Univ Zurich, Univ Hosp Zurich, Diagnost & Intervent Radiol, Zurich, Switzerland
[6] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[7] Hirslanden Zurich, Dept Radiol, Zurich, Switzerland
关键词
Dental implant; Computer-guided surgery; Cone-beam computed tomography; Photon-counting detector computed tomography; Low-dose protocol; Radiation protection; Oral surgery; Maxillofacial surgery; FUTURE; COEFFICIENTS; RELIABILITY; RADIATION; ACCURACY; CT;
D O I
10.1186/s40729-025-00611-z
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose To compare cone-beam computed tomography (CBCT) with photon-counting detector computed tomography (PCD-CT) at equivalent radiation doses, focusing on qualitative and quantitative parameters relevant to dental implant surgery. Methods This ex vivo comparative study of porcine specimens assessed five imaging protocols with both CBCT and PCD-CT at three effective radiation dose levels (high: 360 mu Sv, standard: 145 mu Sv, low: 20 mu Sv) to evaluate image quality, artifact burden, metal artifact susceptibility, and quantitative bone measurements in the mandibular region. Three blinded readers analyzed the data using a 5-point Likert scale (5 = highest to 1 = lowest rating) and performed linear bone measurements at implant planning sites. Statistical analysis included descriptive statistics and inter-reader reliability assessment using intraclass correlation coefficients (ICC). Results Each reader evaluated 30 data sets (12 CBCT, 18 PCD-CT), with 24 implant planning sites per imaging protocol. High-dose PCD-CT demonstrated the best image quality and diagnostic interpretability (4.89 +/- 0.27), followed by standard-dose PCD-CT and CBCT (4.50 +/- 0.73; 4.33 +/- 0.61), with low-dose protocols showing intermediate quality with higher artifact burden. In comparison to CBCT, PCD-CT demonstrated superior performance in reducing implant-induced artifacts across all protocols. Quantitative bone measurements showed minimal variability, meeting clinical precision requirements for computer-assisted implant surgery. Both qualitative (ICCs:0.70-0.89; p < 0.001) and quantitative (ICCs:0.79-1; p < 0.001) analyses demonstrated high reliability, regardless of the reader's experience. Conclusions PCD-CT demonstrated superior image quality and reduced artifacts compared with CBCT at all radiation dose levels. These findings highlight PCD-CT's potential to enhance implant planning and improve clinical outcomes with reduced radiation exposure while maintaining diagnostic accuracy.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Cone-Beam Computed Tomography Evaluation of the Submandibular Fossa in a Group of Dental Implant Patients
    Nilsun, Bagis
    Canan, Boz
    Evren, Hincal
    Kaan, Orhan
    IMPLANT DENTISTRY, 2019, 28 (04) : 329 - 339
  • [22] A deep learning approach for dental implant planning in cone-beam computed tomography images
    Sevda Kurt Bayrakdar
    Kaan Orhan
    Ibrahim Sevki Bayrakdar
    Elif Bilgir
    Matvey Ezhov
    Maxim Gusarev
    Eugene Shumilov
    BMC Medical Imaging, 21
  • [23] Innovative advances in pediatric radiology: computed tomography reconstruction techniques, photon-counting detector computed tomography, and beyond
    Mese, Ismail
    Mese, Ceren Altintas
    Demirsoy, Ugur
    Anik, Yonca
    PEDIATRIC RADIOLOGY, 2024, 54 (01) : 1 - 11
  • [24] Innovative advances in pediatric radiology: computed tomography reconstruction techniques, photon-counting detector computed tomography, and beyond
    Ismail Mese
    Ceren Altintas Mese
    Ugur Demirsoy
    Yonca Anik
    Pediatric Radiology, 2024, 54 : 1 - 11
  • [25] Comparison of Methods for Acceptance and Constancy Testing in Dental Cone-beam Computed Tomography
    Steiding, C.
    Kolditz, D.
    Kalender, W.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2015, 187 (04): : 283 - 290
  • [26] Cone-beam computed tomography for trauma
    Gupta, Saurabh
    Martinson, James R.
    Ricaurte, Daniel
    Scalea, Thomas M.
    Morrison, Jonathan J.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2020, 89 (03): : E34 - E40
  • [27] Clinical applications of cone-beam computed tomography in dental practice
    Scarfe, William C.
    Farman, Allan G.
    Sukovic, Predag
    JOURNAL OF THE CANADIAN DENTAL ASSOCIATION, 2006, 72 (01): : 75 - 80
  • [28] Comparison of digital dental images yielded by digital dental casts, cone-beam computed tomography, and multislice computed tomography for measurement of dental area
    Sang-Hoon Kang
    Yeon-Ho Kim
    Moon-Key Kim
    Oral Radiology, 2017, 33 : 23 - 31
  • [29] Comparison of digital dental images yielded by digital dental casts, cone-beam computed tomography, and multislice computed tomography for measurement of dental area
    Kang, Sang-Hoon
    Kim, Yeon-Ho
    Kim, Moon-Key
    ORAL RADIOLOGY, 2017, 33 (01) : 23 - 31
  • [30] Photon-Counting Detector Computed Tomography Versus Energy-Integrating Detector Computed Tomography for Coronary Artery Calcium Quantitation
    McCollough, Cynthia H.
    Winfree, Tim N.
    Melka, Elnata F.
    Rajendran, Kishore
    Carter, Rickey E.
    Leng, Shuai
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2024, 48 (02) : 212 - 216