Comparison of cone-beam computed tomography with photon-counting detector computed tomography for dental implant surgery

被引:0
作者
Husain, Adib Al-Haj [1 ,2 ,3 ,4 ]
Mergen, Victor [5 ]
Valdec, Silvio [1 ]
Husain, Nadin Al-Haj [6 ]
Stadlinger, Bernd [1 ]
Essig, Harald [2 ]
Frauenfelder, Thomas [5 ]
Kessler, Peter [4 ]
Lie, Suen An Nynke [4 ]
Alkadhi, Hatem [5 ]
Winklhofer, Sebastian [3 ,7 ]
机构
[1] Univ Zurich, Ctr Dent Med, Clin Cranio Maxillofacial & Oral Surg, Plattenstr 11, CH-8032 Zurich, Switzerland
[2] Univ Zurich, Univ Hosp Zurich, Dept Cranio maxillofacial & Oral Surg, Zurich, Switzerland
[3] Univ Zurich, Univ Hosp Zurich, Clin Neurosci Ctr, Dept Neuroradiol, Zurich, Switzerland
[4] Maastricht Univ, GROW Sch Oncol & Reprod, Dept Cranio Maxillofacial Surg, Med Ctr, Maastricht, Netherlands
[5] Univ Zurich, Univ Hosp Zurich, Diagnost & Intervent Radiol, Zurich, Switzerland
[6] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[7] Hirslanden Zurich, Dept Radiol, Zurich, Switzerland
关键词
Dental implant; Computer-guided surgery; Cone-beam computed tomography; Photon-counting detector computed tomography; Low-dose protocol; Radiation protection; Oral surgery; Maxillofacial surgery; FUTURE; COEFFICIENTS; RELIABILITY; RADIATION; ACCURACY; CT;
D O I
10.1186/s40729-025-00611-z
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose To compare cone-beam computed tomography (CBCT) with photon-counting detector computed tomography (PCD-CT) at equivalent radiation doses, focusing on qualitative and quantitative parameters relevant to dental implant surgery. Methods This ex vivo comparative study of porcine specimens assessed five imaging protocols with both CBCT and PCD-CT at three effective radiation dose levels (high: 360 mu Sv, standard: 145 mu Sv, low: 20 mu Sv) to evaluate image quality, artifact burden, metal artifact susceptibility, and quantitative bone measurements in the mandibular region. Three blinded readers analyzed the data using a 5-point Likert scale (5 = highest to 1 = lowest rating) and performed linear bone measurements at implant planning sites. Statistical analysis included descriptive statistics and inter-reader reliability assessment using intraclass correlation coefficients (ICC). Results Each reader evaluated 30 data sets (12 CBCT, 18 PCD-CT), with 24 implant planning sites per imaging protocol. High-dose PCD-CT demonstrated the best image quality and diagnostic interpretability (4.89 +/- 0.27), followed by standard-dose PCD-CT and CBCT (4.50 +/- 0.73; 4.33 +/- 0.61), with low-dose protocols showing intermediate quality with higher artifact burden. In comparison to CBCT, PCD-CT demonstrated superior performance in reducing implant-induced artifacts across all protocols. Quantitative bone measurements showed minimal variability, meeting clinical precision requirements for computer-assisted implant surgery. Both qualitative (ICCs:0.70-0.89; p < 0.001) and quantitative (ICCs:0.79-1; p < 0.001) analyses demonstrated high reliability, regardless of the reader's experience. Conclusions PCD-CT demonstrated superior image quality and reduced artifacts compared with CBCT at all radiation dose levels. These findings highlight PCD-CT's potential to enhance implant planning and improve clinical outcomes with reduced radiation exposure while maintaining diagnostic accuracy.
引用
收藏
页数:11
相关论文
共 32 条
  • [1] A H Pakravan, 2019, J Biomed Phys Eng, V9, P525, DOI 10.31661/jbpe.v0i0.466
  • [2] The Future of Computed Tomography Personalized, Functional, and Precise
    Alkadhi, Hatem
    Euler, Andre
    [J]. INVESTIGATIVE RADIOLOGY, 2020, 55 (09) : 545 - 555
  • [3] Optimizing radiation safety in dentistry Clinical recommendations and regulatory considerations
    Benavides, Erika
    Krecioch, Joseph R.
    Connolly, Roger T.
    Allareddy, Trishul
    Buchanan, Allison
    Spelic, David
    O'Brien, Kelly K.
    Keels, Martha Ann
    Mascarenhas, Ana Karina
    Duong, Mai-Ly
    Aerne-Bowe, Mickie J.
    Ziegler, Kathleen M.
    Lipman, Ruth D.
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2024, 155 (04) : 280 - 293.e4
  • [4] A New Frontier in Temporal Bone Imaging: Photon-Counting Detector CT Demonstrates Superior Visualization of Critical Anatomic Structures at Reduced Radiation Dose
    Benson, J. C.
    Rajendran, K.
    Lane, J. I.
    Diehn, F. E.
    Weber, N. M.
    Thorne, J. E.
    Larson, N. B.
    Fletcher, J. G.
    McCollough, C. H.
    Leng, S.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2022, : 579 - 584
  • [5] Accuracy of linear measurements for implant planning based on low-dose cone beam CT protocols: a systematic review and meta-analysis
    Carneiro, Ana Luiza E.
    Reis, Isabella N. R.
    Bitencourt, Fernando Valentim
    Salgado, Daniela M. R. A.
    Costa, Claudio
    Spin-Neto, Rubens
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2024, 53 (04) : 207 - 221
  • [6] Dillinger D, 2024, Diagnostics (Basel), V14
  • [7] Reliability and Accuracy of Cone Beam Computed Tomography Versus Conventional Multidetector Computed Tomography for Image-Guided Craniofacial Implant Planning: An In Vitro Study
    Dings, Jeroen Paulus Johannes
    Verhamme, Luc
    Merkx, Matthias A. W.
    Xi, Tong
    Meijer, Gert J.
    Maal, Thomas J.
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (03) : 665 - 672
  • [8] Accuracy of linear measurements on CBCT images related to presurgical implant treatment planning: A systematic review
    Fokas, George
    Vaughn, Vida M.
    Scarfe, William C.
    Bornstein, Michael M.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 : 393 - 415
  • [9] Long-term (10-year) dental implant survival: A systematic review and sensitivity meta-analysis
    Howe, Mark-Steven
    Keys, William
    Richards, Derek
    [J]. JOURNAL OF DENTISTRY, 2019, 84 : 9 - 21
  • [10] Cone beam computed tomography in implant dentistry: recommendations for clinical use
    Jacobs, Reinhilde
    Salmon, Benjamin
    Codari, Marina
    Hassan, Bassam
    Bornstein, Michael M.
    [J]. BMC ORAL HEALTH, 2018, 18