Solving the problem of power ripples for a multi-rotor wind turbine system using fractional-order third-order sliding mode algorithms

被引:1
作者
Benbouhenni, Habib [1 ]
Yahdou, Adil [2 ]
Djilali, Abdelkadir Belhadj [2 ]
Bizon, Nicu [3 ]
Colak, Ilhami [4 ]
Elbarbary, Z. M. S. [5 ,6 ]
Parayangat, Muneer [5 ,6 ]
机构
[1] Natl Polytech Sch Oran Maurice Audin, LAAS Lab, BP 1523 Oran El Mnaouer, Oran, Algeria
[2] Hassiba Benbouali Univ Chlef, Fac Technol, Dept Elect Engn, Lab Genie Elect & Energies Renouvelables LGEER, Chlef, Algeria
[3] Natl Univ Sci & Technol POLITEHN Bucharest, Pitesti Univ Ctr, Pitesti 110040, Romania
[4] Istinye Univ, Istanbul, Turkiye
[5] King Khalid Univ, Coll Engn, Dept Elect Engn, POB 394, Abha 61421, Saudi Arabia
[6] King Khalid Univ, Ctr Engn & Technol Innovat, Abha 61421, Saudi Arabia
关键词
Fractional-order third-order sliding mode control; Power quality; Multi-rotor wind turbine; Induction generator; FED INDUCTION GENERATOR; VECTOR CONTROL; PI CONTROLLERS; DESIGN; OPTIMIZATION; DRIVEN; SENSOR; WECS; SMC;
D O I
10.1038/s41598-025-89636-3
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Power quality is one of the most prominent challenges hindering the spread and use of direct power control (DPC) in the field of control, especially for induction generator (IG) control. The lower power quality in the case of using the DPC approach is due to the use of hysteresis comparators. This work proposes a new controller to overcome the drawbacks of the DPC approach, such as low robustness and high total harmonic distortion (THD) value of current for IG present in multi-rotor wind turbine (MRWT) based power system. The proposed controller is fractional-order third-order sliding mode control (FOTOSMC), as this controller is used to determine reference values for a voltage. In addition to using the FOTOSMC controller, the pulse width modulation strategy is used to control the operation of the machine inverter. The proposed approach differs from the traditional DPC approach and existing controls. This proposed approach is characterized by high robustness and high performance in improving power quality. The DPC approach based on the FOTOSMC controller was implemented in MATLAB with a comparison to the traditional DPC approach and some related works in terms of response time, jitter, steady-state error, and overshoot. Simulations under different wind conditions are performed to evaluate the designed strategy's performance and robustness against conventional methods, revealing substantial improvements in dynamic response and stability. The results show the superior dynamic performance of the developed algorithm in terms of enhancing the quality of active power (37.99%, 55.04%, and 44.44%) and reactive power (49.17%, 27.27%, and 30.87%) in the two tests compared to the DPC. This control method effectively reduces the THD by 42.35%, 41.25%, and 31.36% compared to the DPC, resulting in a more efficient and reliable wind energy conversion system. This research confirms the effectiveness and efficiency of the proposed approach in renewable energy applications. It promotes the most efficient and sustainable energy solutions, making it a promising solution in other industrial applications.
引用
收藏
页数:27
相关论文
共 68 条
[41]  
Yusoff NAM, 2017, International Journal of Power Electronics and Drive Systems (IJPEDS), V8, P1776, DOI [10.11591/ijpeds.v8.i4.pp1776-1784, 10.11591/ijpeds.v8i4.pp1776-1784, DOI 10.11591/IJPEDS.V8I4.PP1776-1784]
[42]   Enhanced control technique for a sensor-less wind driven doubly fed induction generator for energy conversion purpose [J].
Mossa, Mahmoud A. ;
Echeikh, Hamdi ;
Iqbal, Atif .
ENERGY REPORTS, 2021, 7 :5815-5833
[43]  
Moualdia A, 2012, INT J RENEW ENERGY R, V2, P300
[44]   Maximum Power Extraction from Wind Turbines Using a Fault-Tolerant Fractional-Order Nonsingular Terminal Sliding Mode Controller [J].
Mousavi, Yashar ;
Bevan, Geraint ;
Kucukdemiral, Ibrahim Beklan ;
Fekih, Afef .
ENERGIES, 2021, 14 (18)
[45]  
Nadour M, 2017, INT J RENEW ENERGY R, V7, P1307
[46]  
Nasef SA, 2022, INT J RENEW ENERGY R, V12, P408, DOI 10.20508/ijrer.v12i1.12770.g8422
[47]   PID-type Terminal Sliding Mode Control for Permanent Magnet Synchronous Generator-based Enhanced Wind Energy Conversion Systems [J].
Nasiri, Mojtaba ;
Mobayen, Saleh ;
Arzani, Ali .
CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2022, 8 (04) :993-1003
[48]  
Orhan K., 2022, Int. J. Renew. Energy Research-IJRER, V12, P134, DOI [10.20508/ijrer.v12i1.12448.g8383, DOI 10.20508/IJRER.V12I1.12448.G8383]
[49]   Multi-Resonant-Based Sliding Mode Control of DFIG-Based Wind System under Unbalanced and Harmonic Network Conditions [J].
Quan, Yu ;
Hang, Lijun ;
He, Yuanbin ;
Zhang, Yao .
APPLIED SCIENCES-BASEL, 2019, 9 (06)
[50]   Rotor current controller with voltage harmonics compensation for a DFIG operating under unbalanced and distorted stator voltage [J].
Ramos, C. J. ;
Martins, A. P. ;
Carvalho, A. S. .
IECON 2007: 33RD ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-3, CONFERENCE PROCEEDINGS, 2007, :1287-1292