Noise and sound in the intensive care unit: a cohort study

被引:0
|
作者
Tahvili, A. [1 ]
Waite, A. [1 ,2 ]
Hampton, T. [1 ,2 ,3 ]
Welters, I. [1 ,2 ]
Lee, P. J. [4 ]
机构
[1] Univ Liverpool, Inst Life Course & Med Sci, Liverpool, England
[2] Liverpool Univ Hosp NHS Fdn Trust, Intens Care Unit, Royal Liverpool Univ Hosp, Liverpool, England
[3] Univ Liverpool Liverpool Sch Trop Med, Dept Clin Sci, Pembroke Pl, Liverpool L3 5QA, Merseyside, England
[4] Univ Liverpool, Sch Architecture, Acoust Res Unit, Liverpool, England
来源
SCIENTIFIC REPORTS | 2025年 / 15卷 / 01期
关键词
Noise; Intensive care units (ICU); Acoustics; Health facilities; Occupational health; ENVIRONMENTAL NOISE; SLEEP DISRUPTION; FALSE ALARMS; DELIRIUM; PERFORMANCE; REDUCTION; EFFICACY; BURNOUT; QUALITY; STRESS;
D O I
10.1038/s41598-025-94365-8
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Intensive care units (ICUs) are acknowledged for their propensity for noise, often exhibiting higher sound levels on average than other departments. This is mainly ascribed to a high concentration of medical devices and staff, creating an acoustic environment characterised by a high level of staff activity and a concoction of alarms from therapeutic and monitoring devices. Excessive noise in ICUs has been associated with adverse health effects and human factor impacts acknowledged to negatively affect both patients and healthcare providers. This study aimed to evaluate the sound levels of the Royal Liverpool University Hospital (RLUH) ICU and compare it against recommended guidelines. Prospective sound level measurements were taken from a six-bedded bay within the RLUH ICU between 15th June and 1st July 2022. This audit focussed on sound data that equal or exceeded 87 dBA, in accordance with levels in the UK Noise Regulations. The data involved 11 patients admitted to the bay within the defined timeframe. A retrospective review of the patients' records was conducted to identify potential noisy events during the recording period. Results revealed all LAeq and LAmax measurements exceeded the recommended guidelines. Although HSE exposure limit values were not exceeded, the lowest LAmin value recorded was 44.2 dBA and only one hour from 16 days of recording (less than 1% of the time) fell below international daytime guidelines of 45 dBA. The top documented potential causes of noise were patient repositioning/personal care, medication administration and suctioning. Sound levels in the RLUH ICU considerably exceed national and international guidelines. These findings highlight the need to address the issue of noise pollution in the ICU setting. Hospital staff should consider implementing strategies and interventions for noise reduction in ICUs.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Brighter Days May Be Ahead: Continuous Measurement of Pediatric Intensive Care Unit Light and Sound
    Greenfield, Kara D.
    Karam, Oliver
    Iqbal O'Meara, A. M.
    FRONTIERS IN PEDIATRICS, 2020, 8
  • [32] Evaluation of noise in the neonatal intensive care unit
    Benini, F
    Magnavita, V
    Lago, P
    Arslan, E
    Pisan, P
    AMERICAN JOURNAL OF PERINATOLOGY, 1996, 13 (01) : 37 - 41
  • [33] Vulnerabilities of nurses in an intensive care unit: an integrative review
    Vocci, Marcelli Cristine
    Gallo, Isabella Gandolfi
    Spiri, Wilza Carla
    Borgato, Maria Helena
    Fontes, Cassiana Mendes Bertoncello
    REVISTA BRASILEIRA DE ENFERMAGEM, 2021, 74 (03)
  • [34] Sound pressure levels in the Neonatal Intensive Care Unit
    Peixoto, Priscila Vendramini
    Nabuco de Araujo, Marco Antonio
    Kakehashi, Tereza Yoshiko
    Pinheiro, Eliana Moreira
    REVISTA DA ESCOLA DE ENFERMAGEM DA USP, 2011, 45 (06) : 1308 - 1313
  • [35] Religion, Spirituality, and the Intensive Care Unit The Sound of Silence
    Balboni, Tracy A.
    Balboni, Michael J.
    Fitchett, George
    JAMA INTERNAL MEDICINE, 2015, 175 (10) : 1669 - 1670
  • [36] Questionable sound exposure outside of the womb: frequency analysis of environmental noise in the neonatal intensive care unit
    Lahav, Amir
    ACTA PAEDIATRICA, 2015, 104 (01) : E14 - E19
  • [37] Elevated Sound Levels in the Neonatal Intensive Care Unit: What Is Causing the Problem?
    Mayhew, Kelli J.
    Lawrence, Sarah L.
    Squires, Janet E.
    Harrison, Denise
    ADVANCES IN NEONATAL CARE, 2022, 22 (06) : E207 - E216
  • [38] Promoting Sleep in the Intensive Care Unit
    Beck Edvardsen, Jorunn
    Hetmann, Fredrik
    SAGE OPEN NURSING, 2020, 6
  • [39] An investigation of sound levels on intensive care units with reference to the WHO guidelines
    Darbyshire, Julie L.
    Young, Duncan
    CRITICAL CARE, 2013, 17 (05):
  • [40] Noise pollution in an intensive care unit for nephrology and dialysis
    Buemi, M
    Allegra, A
    Grasso, F
    Mondio, G
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 1995, 10 (12) : 2235 - 2239