Noise and sound in the intensive care unit: a cohort study

被引:0
|
作者
Tahvili, A. [1 ]
Waite, A. [1 ,2 ]
Hampton, T. [1 ,2 ,3 ]
Welters, I. [1 ,2 ]
Lee, P. J. [4 ]
机构
[1] Univ Liverpool, Inst Life Course & Med Sci, Liverpool, England
[2] Liverpool Univ Hosp NHS Fdn Trust, Intens Care Unit, Royal Liverpool Univ Hosp, Liverpool, England
[3] Univ Liverpool Liverpool Sch Trop Med, Dept Clin Sci, Pembroke Pl, Liverpool L3 5QA, Merseyside, England
[4] Univ Liverpool, Sch Architecture, Acoust Res Unit, Liverpool, England
来源
SCIENTIFIC REPORTS | 2025年 / 15卷 / 01期
关键词
Noise; Intensive care units (ICU); Acoustics; Health facilities; Occupational health; ENVIRONMENTAL NOISE; SLEEP DISRUPTION; FALSE ALARMS; DELIRIUM; PERFORMANCE; REDUCTION; EFFICACY; BURNOUT; QUALITY; STRESS;
D O I
10.1038/s41598-025-94365-8
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Intensive care units (ICUs) are acknowledged for their propensity for noise, often exhibiting higher sound levels on average than other departments. This is mainly ascribed to a high concentration of medical devices and staff, creating an acoustic environment characterised by a high level of staff activity and a concoction of alarms from therapeutic and monitoring devices. Excessive noise in ICUs has been associated with adverse health effects and human factor impacts acknowledged to negatively affect both patients and healthcare providers. This study aimed to evaluate the sound levels of the Royal Liverpool University Hospital (RLUH) ICU and compare it against recommended guidelines. Prospective sound level measurements were taken from a six-bedded bay within the RLUH ICU between 15th June and 1st July 2022. This audit focussed on sound data that equal or exceeded 87 dBA, in accordance with levels in the UK Noise Regulations. The data involved 11 patients admitted to the bay within the defined timeframe. A retrospective review of the patients' records was conducted to identify potential noisy events during the recording period. Results revealed all LAeq and LAmax measurements exceeded the recommended guidelines. Although HSE exposure limit values were not exceeded, the lowest LAmin value recorded was 44.2 dBA and only one hour from 16 days of recording (less than 1% of the time) fell below international daytime guidelines of 45 dBA. The top documented potential causes of noise were patient repositioning/personal care, medication administration and suctioning. Sound levels in the RLUH ICU considerably exceed national and international guidelines. These findings highlight the need to address the issue of noise pollution in the ICU setting. Hospital staff should consider implementing strategies and interventions for noise reduction in ICUs.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Noise levels in an academic veterinary intensive care unit
    Dornbusch, Josephine
    Boston, Sarah
    Colee, James
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2020, 30 (06) : 632 - 637
  • [22] Noise, stress, and annoyance in a pediatric intensive care unit
    Morrison, WE
    Haas, EC
    Shaffner, DH
    Garrett, ES
    Fackler, JC
    CRITICAL CARE MEDICINE, 2003, 31 (01) : 113 - 119
  • [23] Noise in the intensive care unit and its influence on sleep quality: a multicenter observational study in Dutch intensive care units
    Simons, Koen S.
    Verweij, Eva
    Lemmens, Paul M. C.
    Jelfs, Sam
    Park, Munhum
    Spronk, Peter E.
    Sonneveld, Johannes P. C.
    Feijen, Hilde-Marieken
    van der Steen, Marijke S.
    Kohlrausch, Armin G.
    van den Boogaard, Mark
    de Jager, Cornelis P. C.
    CRITICAL CARE, 2018, 22
  • [24] Improvement of intensive care unit sound environment and analyses of consequences on sleep: an experimental study
    Waye, Kerstin Persson
    Elmenhorst, Eva-Maria
    Croy, Ilona
    Pedersen, Eja
    SLEEP MEDICINE, 2013, 14 (12) : 1334 - 1340
  • [25] Noise Pollution: Do We Need a Solution? An Analysis of Noise in a Cardiac Care Unit
    Ryan, Kevin M.
    Gagnon, Matthew
    Hanna, Tyler
    Mello, Brad
    Fofana, Mustapha
    Ciottone, Gregory
    Molloy, Michael
    PREHOSPITAL AND DISASTER MEDICINE, 2016, 31 (04) : 432 - 435
  • [26] Noise in the Neonatal Intensive Care Unit What Does the Evidence Tell Us?
    Casavant, Sharon G.
    Bernier, Katherine
    Andrews, Sheena
    Bourgoin, Allison
    ADVANCES IN NEONATAL CARE, 2017, 17 (04) : 265 - 273
  • [27] The Effectiveness of Measures Aimed at Noise Reduction in an Intensive Care Unit
    Kol, Emine
    Demircan, Abid
    Erdogan, Abdullah
    Gencer, Zehra
    Erengin, Hakan
    WORKPLACE HEALTH & SAFETY, 2015, 63 (12) : 539 - 545
  • [28] EVALUATION OF NOISE IN THE NEONATAL INTENSIVE CARE UNIT
    Teixeira, Alessandra
    Fialho, Flavia Andrade
    Avila Vargas, Ieda Maria
    de Souza Martins, Katia Cristina
    Machado, Roberto Vale
    Correia, Maria Efigenia
    REVISTA CUIDARTE, 2011, 2 (01) : 114 - 118
  • [29] Analysis of noise in a neonatal intensive care unit
    Guimaraes, H
    Oliveira, AM
    Spratley, J
    Mateus, M
    dOrey, C
    Coelho, JL
    Souto, A
    Santos, NT
    ARCHIVES DE PEDIATRIE, 1996, 3 (11): : 1065 - 1068
  • [30] Repercussion of noise in the neonatal intensive care unit
    Grecco, Gabriela Menossi
    Tsunemi, Miriam Harumi
    Ferreira Gomes Balieiro, Maria Magda
    Kakehashi, Tereza Yoshiko
    Pinheiro, Eliana Moreira
    ACTA PAULISTA DE ENFERMAGEM, 2013, 26 (01) : 1 - 7