Noise and sound in the intensive care unit: a cohort study

被引:0
|
作者
Tahvili, A. [1 ]
Waite, A. [1 ,2 ]
Hampton, T. [1 ,2 ,3 ]
Welters, I. [1 ,2 ]
Lee, P. J. [4 ]
机构
[1] Univ Liverpool, Inst Life Course & Med Sci, Liverpool, England
[2] Liverpool Univ Hosp NHS Fdn Trust, Intens Care Unit, Royal Liverpool Univ Hosp, Liverpool, England
[3] Univ Liverpool Liverpool Sch Trop Med, Dept Clin Sci, Pembroke Pl, Liverpool L3 5QA, Merseyside, England
[4] Univ Liverpool, Sch Architecture, Acoust Res Unit, Liverpool, England
来源
SCIENTIFIC REPORTS | 2025年 / 15卷 / 01期
关键词
Noise; Intensive care units (ICU); Acoustics; Health facilities; Occupational health; ENVIRONMENTAL NOISE; SLEEP DISRUPTION; FALSE ALARMS; DELIRIUM; PERFORMANCE; REDUCTION; EFFICACY; BURNOUT; QUALITY; STRESS;
D O I
10.1038/s41598-025-94365-8
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Intensive care units (ICUs) are acknowledged for their propensity for noise, often exhibiting higher sound levels on average than other departments. This is mainly ascribed to a high concentration of medical devices and staff, creating an acoustic environment characterised by a high level of staff activity and a concoction of alarms from therapeutic and monitoring devices. Excessive noise in ICUs has been associated with adverse health effects and human factor impacts acknowledged to negatively affect both patients and healthcare providers. This study aimed to evaluate the sound levels of the Royal Liverpool University Hospital (RLUH) ICU and compare it against recommended guidelines. Prospective sound level measurements were taken from a six-bedded bay within the RLUH ICU between 15th June and 1st July 2022. This audit focussed on sound data that equal or exceeded 87 dBA, in accordance with levels in the UK Noise Regulations. The data involved 11 patients admitted to the bay within the defined timeframe. A retrospective review of the patients' records was conducted to identify potential noisy events during the recording period. Results revealed all LAeq and LAmax measurements exceeded the recommended guidelines. Although HSE exposure limit values were not exceeded, the lowest LAmin value recorded was 44.2 dBA and only one hour from 16 days of recording (less than 1% of the time) fell below international daytime guidelines of 45 dBA. The top documented potential causes of noise were patient repositioning/personal care, medication administration and suctioning. Sound levels in the RLUH ICU considerably exceed national and international guidelines. These findings highlight the need to address the issue of noise pollution in the ICU setting. Hospital staff should consider implementing strategies and interventions for noise reduction in ICUs.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Characterization of sound pressure levels and sound sources in the intensive care unit: a 1 week observational study
    Naef, Aileen C.
    Knobel, Samuel E. J.
    Ruettgers, Nicole
    Rossier, Marilyne
    Jeitziner, Marie-Madlen
    Zante, Bjoern
    Muri, Rene M.
    Schefold, Joerg C.
    Nef, Tobias
    Gerber, Stephan M.
    FRONTIERS IN MEDICINE, 2023, 10
  • [2] Noise exposure in a neonatal intensive care unit Is there a day-night difference in sound exposure?
    Backhaus, C.
    Carl, A.
    Siebers, S.
    Urlichs, F.
    ZENTRALBLATT FUR ARBEITSMEDIZIN ARBEITSSCHUTZ UND ERGONOMIE, 2023, 73 (01): : 24 - 31
  • [3] Prospective cohort study on noise levels in a pediatric cardiac intensive care unit
    Guerra, Gonzalo Garcia
    Joffe, Ari R.
    Sheppard, Cathy
    Pugh, Jodie
    Moez, Elham Khodayari
    Dinu, Irina A.
    Jou, Hsing
    Hartling, Lisa
    Vohra, Sunita
    JOURNAL OF CRITICAL CARE, 2018, 44 : 318 - 322
  • [4] Impact of intensive care unit light and noise exposure on critically ill patients
    Simons, K. S.
    van den Boogaard, M.
    de Jager, C. P. C.
    NETHERLANDS JOURNAL OF CRITICAL CARE, 2019, 27 (04): : 145 - 149
  • [5] Sound in Time: An observational study to identify the sources of sound and their relative contribution to the sound environment of an intensive care unit
    Dawson, Deborah
    Barham, Richard
    Hamilton, Mark
    Philips, Barbara
    APPLIED ACOUSTICS, 2022, 188
  • [6] A pilot study of sound levels in an Australian adult general intensive care unit
    Elliott, Rosalind M.
    McKinley, Sharon M.
    Eager, David
    NOISE & HEALTH, 2010, 12 (46) : 26 - 36
  • [7] Identifying determinants of noise in a medical intensive care unit
    Crawford, Kathryn J.
    Barnes, Lindsey A.
    Peters, Thomas M.
    Falk, Jeffrey
    Gehlbach, Brian K.
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2018, 15 (12) : 810 - 817
  • [8] Levels and sources of sound in the intensive care unit - an observational study of three room types
    Tegnestedt, C.
    Gunther, A.
    Reichard, A.
    Bjurstrom, R.
    Alvarsson, J.
    Martling, C. -R.
    Sackey, P.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2013, 57 (08) : 1041 - 1050
  • [9] Monitoring sound and light continuously in an intensive care unit patient room: A pilot study
    Voigt, Louis P.
    Reynolds, Kelly
    Mehryar, Maryam
    Chan, Wai Soon
    Kostelecky, Natalie
    Pastores, Stephen M.
    Halpern, Neil A.
    JOURNAL OF CRITICAL CARE, 2017, 39 : 36 - 39
  • [10] Noise exposure among staff in intensive care units and the effects of unit-based noise management: a monocentric prospective longitudinal study
    Armbruster, Christoph
    Walzer, Stefan
    Witek, Sandra
    Ziegler, Sven
    Farin-Glattacker, Erik
    BMC NURSING, 2023, 22 (01)