A Multicenter Study on Clinical Outcomes of Simultaneous Implantable Collamer Lens Removal and Phacoemulsification with Intraocular Lens Implantation in Eyes Developing Cataract

被引:0
作者
Kamiya, Kazutaka [1 ]
Shimizu, Kimiya [2 ]
Kitazawa, Yoshihiro [3 ]
Kojima, Takashi [4 ]
Nakamura, Tomoaki [4 ]
Ichikawa, Kazuo [5 ]
Fujimoto, Kahoko [6 ]
机构
[1] Kitasato Univ, Visual Physiol, Sch Allied Hlth Sci, 1-15-1 Kitasato, Sagamihara, Kanagawa 2520373, Japan
[2] Sanno Hosp, Dept Ophthalmol, Tokyo, Japan
[3] Sapia Tower Eye Clin Tokyo, Tokyo, Japan
[4] Nagoya Eye Clin, Nagoya, Aichi, Japan
[5] Chukyo Eye Clin, Nagoya, Aichi, Japan
[6] Fujimoto Eye Clin, Osaka, Japan
关键词
Implantable collamer lens; Lens extraction; Cataract surgery; Predictability; Endothelial cell loss; CONTACT-LENS; MODERATE; MYOPIA; EXTRACTION;
D O I
10.1007/s40123-024-01078-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Introduction: This study evaluated the clinical outcomes of simultaneous implantable collamer lens (ICL) removal and phacoemulsification with intraocular lens (IOL) implantation in a multicenter study. Methods: We retrospectively investigated 83 eyes of 72 patients requiring ICL extraction and cataract surgery at five institutions. Preoperatively and 3 months postoperatively, we determined visual acuity (logMAR), spherical equivalent refraction, and endothelial cell density (ECD), in addition to the preoperative backgrounds and the postoperative complications. Results: The patients' age at the time of cataract surgery was 49.8 +/- 6.8 years, and the axial length was 28.49 +/- 1.97 mm. The most prevalent type of cataract was anterior subcapsular cataract, followed by nuclear and cortical cataract. Uncorrected and corrected visual acuities significantly improved to 0.09 +/- 0.30 and - 0.12 +/- 0.12 logMAR, respectively (p < 0.001). Sixty-three (76%) and 78 (94%) eyes were within +/- 0.5 D and 1.0 D, respectively, of the targeted correction. The mean percentage of ECD loss was 1.3 +/- 11.3%. No vision-threatening complications were observed in any case. Conclusions: Our multicenter study showed that simultaneous ICL removal and phacoemulsification with IOL implantation is a safe, effective, and predictable procedure, with no significant complications, making it a feasible option for ICL-implanted eyes developing cataracts.
引用
收藏
页码:337 / 350
页数:14
相关论文
共 26 条
  • [1] Ten-year follow-up of posterior chamber phakic intraocular lens with central port design in patients with low and normal vault
    Alfonso-Bartolozzi, Belen
    Fernandez-Vega-Cueto, Luis
    Lisa, Carlos
    Palacios, Ana
    Madrid-Costa, David
    Alfonso, Jose F.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2024, 50 (05) : 441 - 447
  • [2] Results of cataract extraction after implantable contact lens removal
    Bleckmann, H
    Keuch, RJ
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (12) : 2329 - 2333
  • [3] Ten-year clinical outcomes after implantation of a posterior chamber phakic intraocular lens for myopia
    Choi, Jae Hwan
    Lim, Dong Hui
    Nam, Seung Wan
    Yang, Chan Min
    Chung, Eui Sang
    Chung, Tae-Young
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (11) : 1555 - 1561
  • [4] Visual Outcomes of Cataract Surgery in Patients with Previous History of Implantable Collamer Lens
    Del Risco, Norma E.
    Talbot, Chad L.
    Moin, Kayvon A.
    Manion, Garrett N.
    Brown, Alex H.
    Walker, Stephen M.
    Zhong, Ping-Shou
    Zhang, Hanting
    Hoopes, Phillip C.
    Moshirfar, Majid
    [J]. JOURNAL OF CLINICAL MEDICINE, 2024, 13 (15)
  • [5] Incidence of implantable Collamer lens-induced cataract
    Gimbel, Howard V.
    LeClair, Bronson M.
    Jabo, Brice
    Marzouk, Hala
    [J]. CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2018, 53 (05): : 518 - 522
  • [6] Implantable contact lens for moderate to high myopia - Relationship of vaulting to cataract formation
    Gonvers, M
    Bornet, C
    Othenin-Girard, P
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (05) : 918 - 924
  • [7] Clinical Outcomes and Cataract Formation Rates in Eyes 10 Years After Posterior Phakic Lens Implantation for Myopia
    Guber, Ivo
    Mouvet, Victoria
    Bergin, Ciara
    Perritaz, Sylvie
    Othenin-Girard, Philippe
    Majo, Francois
    [J]. JAMA OPHTHALMOLOGY, 2016, 134 (05) : 487 - 494
  • [8] Ultrasound axial length measurement in biphakic eyes
    Hoffer, KJ
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (05) : 961 - 965
  • [9] Eight-Year Follow-up of Posterior Chamber Phakic Intraocular Lens Implantation for Moderate to High Myopia
    Igarashi, Akihito
    Shimizu, Kimiya
    Kamiya, Kazutaka
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (03) : 532 - 539
  • [10] Demographics of patients having cataract surgery after laser in situ keratomileusis
    Iijima, Kei
    Kamiya, Kazutaka
    Shimizu, Kimiya
    Igarashi, Akihito
    Komatsu, Mari
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (02) : 334 - 338