Unveiling the hidden risk: a case of severe jaundice triggered by intra-aortic balloon pump after cardiac surgery

被引:0
作者
Wang, Han [1 ]
Chen, Zerui [2 ]
Lei, Liming [1 ]
Fang, Miaoxian [1 ]
机构
[1] Southern Med Univ, Guangdong Prov Peoples Hosp, Guangdong Cardiovasc Inst, Guangdong Acad Med Sci,Dept Intens Care Unit Cardi, Guangzhou 510080, Guangdong, Peoples R China
[2] Southern Med Univ, Guangdong Prov Peoples Hosp, Guangdong Acad Med Sci, Dept Cardiac Surg,Guangdong Cardiovasc Inst, Guangzhou 510080, Guangdong, Peoples R China
关键词
Intra-aortic balloon pump; Cardiac surgery; Hepatic dysfunction; Jaundice; OCCLUSION;
D O I
10.1186/s13019-025-03388-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundThe Intra-Aortic Balloon Pump (IABP) is a widely utilized technique to provide circulatory support for critically ill patients with cardiac dysfunction. While IABP therapy offers clinical benefits, the placement of an IABP catheter can potentially lead to a range of complications in certain high-risk patients. This case report presents a rare instance of progressive jaundice associated with IABP implantation.Case presentationThe patient was a 56-year-old female who had undergone cardiac valve surgery due to rheumatic combined valve disease. She subsequently developed postoperative low cardiac output syndrome, necessitating the implementation of IABP support. However, the patient exhibited a rapid deterioration in jaundice, coupled with aberrant liver function and suspicion of concurrent pancreatitis. Further thoracoabdominal computed tomography (CT) examinations revealed that when the IABP balloon was fully inflated, the aorta was completely occluded. The diagnosis of hepatic impairment was suspected to likely result from a reduced hepatic blood flow caused by obstruction of the celiac trunk related to the occlusive IABP balloon. Therefore, the IABP was removed, leading to a gradual amelioration of jaundice symptoms as well as bilirubin levels.ConclusionsThis case advocates a reevaluation of the strategy for selecting the size of the IABP balloon, particularly in high-risk patient populations. A marginally smaller balloon size may be warranted to mitigate the risk of vascular-related complications. In cases presenting with progressive jaundice and hepatic impairment following IABP insertion, proactive imaging studies should be promptly conducted to ascertain their correlation with the IABP placement. If there is suspicion of visceral ischemia associated with the IABP balloon, immediate removal of the device should be undertaken to prevent irreversible adverse events.
引用
收藏
页数:6
相关论文
共 16 条
[1]   Should We Consider the Ethnic Difference in Selecting Size of Intraaortic Balloon by Commercial Guideline? [J].
Cho, Young-Seok ;
Lim, Cheong ;
Han, Mi-Jung ;
Chun, Eun Ju ;
Choi, Sang Il ;
Park, Kay-Hyun ;
Chae, In-Ho ;
Choi, Dong-Ju .
ASAIO JOURNAL, 2009, 55 (05) :519-522
[2]   Vascular complications following intra-aortic balloon pump implantation: an updated review [J].
de Jong, Monique M. ;
Lorusso, Roberto ;
Al Awami, Fatima ;
Matteuci, Francesco ;
Parise, Orlando ;
Lozekoot, Pieter ;
Bonacchi, Massimo ;
Maessen, Jos G. ;
Johnson, Daniel M. ;
Gelsomino, Sandro .
PERFUSION-UK, 2018, 33 (02) :96-104
[3]   Risk factors, resource use, and cost of postoperative low cardiac output syndrome [J].
Duncan, Andra E. ;
Kartashov, Alex ;
Robinson, Scott B. ;
Randall, Doug ;
Zhang, Kan ;
Luber, John ;
James, Roberta A. ;
Halvorson, Sven ;
Bokesch, Paula .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2022, 163 (05) :1890-+
[4]   Complications related to intra-aortic balloon pump in cardiac surgery: A decade later [J].
Elahi, MM ;
Chetty, GK ;
Kirke, R ;
Azeem, T ;
Hartshorne, R ;
Spyt, TJ .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2005, 29 (06) :591-594
[5]   Intra-aortic balloon pump: Looking at the other side [J].
Gelsomino, Sandro ;
de Jong, Monique M. J. .
ARTIFICIAL ORGANS, 2021, 45 (02) :159-162
[6]   Comparing short versus standard-length balloon for intra-aortic counterpulsation: results from a porcine model of myocardial ischaemia-reperfusion [J].
Gelsomino, Sandro ;
Lozekoot, Pieter W. J. ;
Lorusso, Roberto ;
de Jong, Monique M. J. ;
Parise, Orlando ;
Matteucci, Francesco ;
Luca, Fabiana ;
La Meir, Mark ;
Gensini, Gian Franco ;
Maessen, Jos G. .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2016, 49 (05) :1361-1369
[7]   Survival following cardiogenic shock caused by acute left main coronary artery total occlusion - A case report and review of the literature [J].
Itoh, T ;
Fukami, K ;
Oriso, S ;
Umemura, J ;
Nakajima, J ;
Obonai, H ;
Hiramori, K .
ANGIOLOGY, 1997, 48 (02) :163-171
[8]   Mechanical Support in Early Cardiogenic Shock: What Is the Role of Intra-aortic Balloon Counterpulsation? [J].
Kimman, Jesse R. ;
Van Mieghem, Nicolas M. ;
Endeman, Henrik ;
Brugts, Jasper J. ;
Constantinescu, Alina A. ;
Manintveld, Olivier C. ;
Dubois, Eric A. ;
den Uil, Corstiaan A. .
CURRENT HEART FAILURE REPORTS, 2020, 17 (05) :247-260
[9]   Development and Validation of a Prediction Score for Low-Cardiac-Output Syndrome After Adult Cardiac Surgery [J].
Mendes, Manuel Azevedo ;
Fabre, Marie ;
Amabili, Philippe ;
Jaquet, Oceane ;
Donneau, Anne-Francoise ;
Bonhomme, Vincent ;
Hans, Gregory A. .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2023, 37 (10) :1967-1973
[10]   Basic principles of the intraaortic balloon pump and mechanisms affecting its performance [J].
Papaioannou, TG ;
Stefanadis, C .
ASAIO JOURNAL, 2005, 51 (03) :296-300