Enhancing fixation stability in proximal humerus fractures: screw orientation optimization in PHILOS plates through finite element analysis and biomechanical testing

被引:0
作者
Liu, Jichao [1 ]
Zhang, Ziyan [1 ]
Li, Peng [2 ]
Piao, Chengdong [1 ]
机构
[1] Second Hosp Jilin Univ, Dept Orthoped, Changchun, Jilin, Peoples R China
[2] Jilin Univ, Dept Engn Mech, Changchun, Jilin, Peoples R China
来源
SCIENTIFIC REPORTS | 2024年 / 14卷 / 01期
关键词
Proximal humerus fractures; Finite element analysis; PHILOS; Biomechanics; Parametric optimization; LOCKING PLATE; BONE-DENSITY; JOINT LOADS; EPIDEMIOLOGY; MODELS;
D O I
10.1038/s41598-024-78702-x
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The optimal treatment strategy for proximal humerus fractures (PHFs) is debatable owing to the relatively high failure rate of locking plates. Optimizing implants may enhance the fixation stability of PHFs and reduce the rate of mechanical failures. We developed a finite element (FE) model to simulate the treatment of PHFs with Proximal Humerus Internal Locking System (PHILOS) plates. The model evaluated the average bone strain around the screw tips under vertical loading (as an alternative to the risk of cyclic screw cutout failure verified through biomechanical testing) to minimize this strain and maximize predicted fixation stability. After determining the optimal screw configuration, further FE analysis and in vitro biomechanical testing were conducted on both standard and optimized PHILOS screw orientation to assess whether the optimized plates have biomechanical advantages over the standard plates. The FE-based optimized configuration exhibited significantly lower bone strain around the implant than the standard PHILOS screw orientation (- 17.24%, p < 0.001). In both FE analysis and in vitro biomechanical testing, the optimized PHILOS plates achieved significantly lower average bone strain around the screws (p < 0.05), more uniform stress distribution, and greater structural stiffness (p < 0.05) than the standard PHILOS screw orientation. Our results show that biomechanical performance of the PHILOS plates can be improved by altering the orientation of the locking screws. This approach may be useful for future patient-specific design optimization of implants for other fractures.
引用
收藏
页数:14
相关论文
共 41 条
  • [1] Court-Brown C.M., Caesar B., Epidemiology of adult fractures: A review, Injury, 37, pp. 691-697, (2006)
  • [2] Roux A., Et al., Epidemiology of proximal humerus fractures managed in a trauma center, Orthop. Traumatol.: Surg. Res, 98, pp. 715-719, (2012)
  • [3] Patel A.H., Et al., Trending a decade of proximal humerus fracture management in older adults, JSES Int, 6, pp. 137-143, (2022)
  • [4] Chu S.P., Et al., Risk factors for proximal humerus fracture, Am. J. Epidemiol, 160, pp. 360-367, (2004)
  • [5] Oldrini L.M., Et al., PHILOS synthesis for proximal humerus fractures has high complications and reintervention rates: A systematic review and meta-analysis, Life, (2022)
  • [6] Hamandi F., Laughlin R., Goswami T., Failure analysis of PHILOS plate construct used for pantalar arthrodesis paper II—screws and FEM simulations, Metals, (2018)
  • [7] Sudkamp N., Et al., Open reduction and internal fixation of proximal humeral fractures with use of the locking proximal humerus plate. Results of a prospective, multicenter, observational study, J. Bone Joint Surg. Am, 91, pp. 1320-1328, (2009)
  • [8] Kralinger F., Et al., The influence of local bone density on the outcome of one hundred and fifty proximal humeral fractures treated with a locking plate, J. Bone Joint Surg. Am, 96, pp. 1026-1032, (2014)
  • [9] Hengg C., Et al., Cement augmentation of the proximal humerus internal locking system in elderly patients: A multicenter randomized controlled trial, Arch. Orthop. Trauma Surg, 139, pp. 927-942, (2019)
  • [10] Panagiotopoulou V.C., Varga P., Richards R.G., Gueorguiev B., Giannoudis P.V., Late screw-related complications in locking plating of proximal humerus fractures: A systematic review, Injury, 50, pp. 2176-2195, (2019)