Scanning electron microscopy evaluation of enamel surfaces using different air-polishing powders in the orthodontic setting: an in vitro study

被引:1
作者
Ratzka, Philipp [1 ,2 ,3 ]
Zaslansky, Paul [2 ,3 ,4 ]
Jost-Brinkmann, Paul-Georg [1 ,2 ,3 ]
机构
[1] Charite Univ Med Berlin, Dept Orthodont & Dentofacial Orthoped, Assmannshauser Str 4-6, D-14197 Berlin, Germany
[2] Free Univ Berlin, Assmannshauser Str 4-6, D-14197 Berlin, Germany
[3] Humboldt Univ, Assmannshauser Str 4-6, D-14197 Berlin, Germany
[4] Charite Univ Med Berlin, Dept Operat & Prevent Dent, Assmannshauser Str 4-6, D-14197 Berlin, Germany
来源
JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE | 2024年 / 85卷 / 06期
关键词
Enamel roughness; Prophylaxis; AIR-FLOW (R); Erythritol; Sodium bicarbonate; WHITE SPOT LESIONS; RANDOMIZED CONTROLLED-TRIAL; ROUGHNESS; PERCEPTION; DENTIN; SYSTEM; CARIES; RISK;
D O I
10.1007/s00056-023-00466-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose The aim of this in vitro study was to quantify and compare changes of the enamel surface caused by periodical use of different air-polishing powders during multibracket therapy. Methods Bovine high-gloss polished enamel specimens were air-polished using an AIR-FLOW (R) Master Piezon with maximum powder and water settings. Each specimen was blasted with sodium bicarbonate (AIR-FLOW (R) Powder Classic, Electro Medical Systems, Munich, Germany) and erythritol (AIR-FLOW (R) Powder Plus, Electro Medical Systems). Blasting duration was adapted to the powders' cleaning efficacy and corresponded to 25 air-polishing treatments in a patient with braces. A spindle apparatus ensured uniform guidance at a distance of 4mm and a 90 degrees angle. Qualitative and quantitative assessments were performed with the use of low vacuum scanning electron microscopy. Following external filtering and image processing, arithmetical square height (S-a) and root mean square height (S-q) were determined. Results Both prophy powders caused a significant increase in enamel roughness. Surfaces blasted with sodium bicarbonate (S-a=64.35 +/- 36.65nm; S-q=80.14 +/- 44.80nm) showed significantly (p<0.001) higher roughness than samples treated with erythritol (S-a=24.40 +/- 7.42nm; S-q=30.86 +/- 9.30nm). The observed defects in enamel structure caused by sodium bicarbonate extended across prism boundaries. Prism structure remained intact after air-polishing with erythritol. Conclusion Both applied air-polishing powders led to surface alterations. Despite shorter treatment times, sodium bicarbonate was significantly more abrasive than erythritol. Clinicians must compromise between saving time and abrasively removing healthy enamel.
引用
收藏
页码:404 / 413
页数:10
相关论文
共 41 条
[1]   Incidence of white spot lesions among patients treated with self- and conventional ligation systems [J].
Akin, Mehmet ;
Tezcan, Mucella ;
Ileri, Zehra ;
Ayhan, Faruk .
CLINICAL ORAL INVESTIGATIONS, 2015, 19 (06) :1501-1506
[2]  
[Anonymous], 1995, ICH Topic Q 2 (R1) Validation of analytical procedures: text and methodology
[3]   The potential of deciduous and permanent bovine enamel as substitute for deciduous and permanent human enamel: Erosion-abrasion experiments [J].
Attin, Thomas ;
Wegehaupt, Florian ;
Gries, David ;
Wiegand, Annette .
JOURNAL OF DENTISTRY, 2007, 35 (10) :773-777
[4]   EFFECTS OF AN AIR-POWDER POLISHING SYSTEM ON ORTHODONTICALLY BRACKETED AND BANDED TEETH [J].
BARNES, CM ;
RUSSELL, CM ;
GERBO, LR ;
WELLS, BR ;
BARNES, DW .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1990, 97 (01) :74-81
[5]   Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: A review of the literature [J].
Bollen, CML ;
Lambrechts, P ;
Quirynen, M .
DENTAL MATERIALS, 1997, 13 (04) :258-269
[6]   AIRPOLISHING EFFECTS ON ENAMEL, DENTIN, CEMENT AND BONE [J].
BOYDE, A .
BRITISH DENTAL JOURNAL, 1984, 156 (08) :287-291
[7]   A systematic review on the patient perception of periodontal treatment using air polishing devices [J].
Buehler, J. ;
Amato, M. ;
Weiger, R. ;
Walter, C. .
INTERNATIONAL JOURNAL OF DENTAL HYGIENE, 2016, 14 (01) :4-14
[8]   Incidence of white spot lesions among patients treated with clear aligners and traditional braces [J].
Buschang, Peter H. ;
Chastain, David ;
Keylor, Cameron L. ;
Crosby, Doug ;
Julien, Katie C. .
ANGLE ORTHODONTIST, 2019, 89 (03) :359-364
[9]  
Camboni Sara, 2016, J Clin Dent, V27, P13
[10]   Risk factors for incidence and severity of white spot lesions during treatment with fixed orthodontic appliances [J].
Chapman, Joshua A. ;
Roberts, W. Eugene ;
Eckert, George J. ;
Kula, Katherine S. ;
Gonzalez-Cabezas, Carlos .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 138 (02) :188-194