Annual Optimal Performance Analysis of Micro Heat Pipe PV/T under Different Angles in Northwest China

被引:0
|
作者
Liu, Xiaomin [1 ,2 ,3 ,4 ]
Wu, Qingbai [1 ,2 ,3 ]
Li, Jinping [1 ,2 ,3 ]
Novakovic, Vojislav [5 ]
机构
[1] Lanzhou Univ Technol, Sch Energy & Power Engn, Lanzhou 730050, Peoples R China
[2] Collaborat Innovat Ctr Supporting Technol Northwes, Lanzhou 730050, Peoples R China
[3] Gansu Key Lab Complementary Energy Syst Biomass &, Lanzhou 730050, Peoples R China
[4] Gansu Nat Energy Res Inst, Lanzhou 730050, Peoples R China
[5] Norwegian Univ Sci & Technol, Dept Energy & Proc Engn, NO-7491 Trondheim, Norway
基金
中国国家自然科学基金;
关键词
solar energy; micro heat pipe PV/T system; greenhouse; optimal angle; SYSTEM;
D O I
10.1007/s11630-025-2082-9
中图分类号
O414.1 [热力学];
学科分类号
摘要
The exploitation of photovoltaic/thermal (PV/T) systems, which facilitate concurrent conversion of solar radiation into electrical and heat energies, presents substantial potential in the solar-abundant northwestern zone of China. This investigation endeavors to evaluate the efficacy of a micro heat pipe (M-HP) PV/T system via exhaustive experimental analysis conducted in Lanzhou. To improve the performance of M-HP-PV/T system, a comparison was made between the optimal angles for each day and the entire year. The system inside greenhouse exhibited an average photovoltaic conversion efficiency (PCE) and thermal conversion efficiency (TCE) of 12.32% and 42.81%. The system of external environment registered average PCE and TCE values of 12.99% and 21.08%. To further understand the system's operational results, a mathematical model was constructed through the integration of experimental data, exhibiting good agreement between the simulated outcomes and empirical observations. The average solar irradiance of daily optimum angle was 728.3 W/m2; the annual optimum angle was 29 degrees with an average solar irradiance of 705.6 W/m2. The average annual total powers at the optimal angle outside the greenhouse and inside the greenhouse were 448.0 W and 398.7 W. The average annual total efficiencies at the optimal angle outside the greenhouse and inside the greenhouse were 40.8% and 56.9%. The total power in the greenhouse was lower by 49.3 W, while total efficiency in the greenhouse was higher by 16.1%.
引用
收藏
页码:400 / 412
页数:13
相关论文
共 50 条
  • [21] Performance analysis of thermosyphon heat pipe using aluminum oxide nanofluid under various angles of inclination
    Reji, Arun Kurien
    Kumaresan, G.
    Sarathi, A.
    Arasappa, G. P. Saiganesh
    Kumar, R. Suriya
    Matthew, M. Shelton
    MATERIALS TODAY-PROCEEDINGS, 2021, 45 : 1211 - 1216
  • [22] Performance comparison of air source heat pump coupling with solar evacuated tube water heater and that with micro heat pipe PV/T
    Li, Jinping
    Sun, Xiaohua
    Zhu, Junjie
    Karkon, Ehsan Gholamian
    Novakovic, Vojislav
    ENERGY, 2024, 300
  • [23] Experiment study on heat transfer enhancement of micro heat pipe PV/T by Reynolds number improvement
    Li, Jinping
    Niu, Mengyao
    Liu, Xiaomin
    Novakovic, Vojislav
    Dai, Jingbo
    Huang, Juanjuan
    Kong, Lingxuan
    Zhang, Dong
    Li, Xiaoxia
    ENERGY, 2023, 282
  • [24] Performance Comparison of Photovoltaic (PV), Heat Pipe Photovoltaic/Thermal (HP-PV/T), and Heat Pipe Solar Thermal Collectors (HP-STC): Energy Analysis
    Mainil, Rahmat Iman
    Afif, Faisal
    Arief, Dodi Sofyan
    Mainil, Afdhal Kurniawan
    Aziz, Azridjal
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2024, 42 (03) : 897 - 904
  • [25] Thermal performance of heat pipe with different micro-groove structures
    Bai Peng-fei
    Tang Yong
    Tang Biao
    Lu Long-sheng
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2008, 15 (Suppl 2): : 240 - 244
  • [26] Thermal performance of heat pipe with different micro-groove structures
    Peng-fei Bai
    Yong Tang
    Biao Tang
    Long-sheng Lu
    Journal of Central South University of Technology, 2008, 15 : 240 - 244
  • [27] Thermal performance of heat pipe with different micro-groove structures
    白鹏飞
    汤勇
    唐彪
    陆龙生
    JournalofCentralSouthUniversityofTechnology, 2008, 15(S2) (S2) : 240 - 244
  • [28] Experimental investigation of a novel vertical loop-heat-pipe PV/T heat and power system under different height differences
    Yu, Min
    Chen, Fucheng
    Zhou, Jinzhi
    Yuan, Yanping
    Fan, Yi
    Li, Guiqiang
    Zhao, Xudong
    Wang, Zhangyuan
    Li, Jing
    Zheng, Siming
    ENERGY, 2022, 254
  • [29] The Experimental Research on Instantaneous Efficiency of PV/T Module Based on Micro Heat Pipe Array
    Quan, Zhenhua
    Wang, Lincheng
    Zhao, Yaohua
    Deng, Yuechao
    Wang, Gang
    Liu, Huimin
    THERMAL, POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 732-733 : 306 - 311
  • [30] Comparative research between two different heat pipe spaces PV/T Systems
    Department of Thermal Science and Energy Engineering, University of Science and Technology of China, Hefei 230026, China
    Taiyangneng Xuebao, 2013, 7 (1172-1176):