Annual Optimal Performance Analysis of Micro Heat Pipe PV/T under Different Angles in Northwest China

被引:0
|
作者
Liu, Xiaomin [1 ,2 ,3 ,4 ]
Wu, Qingbai [1 ,2 ,3 ]
Li, Jinping [1 ,2 ,3 ]
Novakovic, Vojislav [5 ]
机构
[1] Lanzhou Univ Technol, Sch Energy & Power Engn, Lanzhou 730050, Peoples R China
[2] Collaborat Innovat Ctr Supporting Technol Northwes, Lanzhou 730050, Peoples R China
[3] Gansu Key Lab Complementary Energy Syst Biomass &, Lanzhou 730050, Peoples R China
[4] Gansu Nat Energy Res Inst, Lanzhou 730050, Peoples R China
[5] Norwegian Univ Sci & Technol, Dept Energy & Proc Engn, NO-7491 Trondheim, Norway
基金
中国国家自然科学基金;
关键词
solar energy; micro heat pipe PV/T system; greenhouse; optimal angle; SYSTEM;
D O I
10.1007/s11630-025-2082-9
中图分类号
O414.1 [热力学];
学科分类号
摘要
The exploitation of photovoltaic/thermal (PV/T) systems, which facilitate concurrent conversion of solar radiation into electrical and heat energies, presents substantial potential in the solar-abundant northwestern zone of China. This investigation endeavors to evaluate the efficacy of a micro heat pipe (M-HP) PV/T system via exhaustive experimental analysis conducted in Lanzhou. To improve the performance of M-HP-PV/T system, a comparison was made between the optimal angles for each day and the entire year. The system inside greenhouse exhibited an average photovoltaic conversion efficiency (PCE) and thermal conversion efficiency (TCE) of 12.32% and 42.81%. The system of external environment registered average PCE and TCE values of 12.99% and 21.08%. To further understand the system's operational results, a mathematical model was constructed through the integration of experimental data, exhibiting good agreement between the simulated outcomes and empirical observations. The average solar irradiance of daily optimum angle was 728.3 W/m2; the annual optimum angle was 29 degrees with an average solar irradiance of 705.6 W/m2. The average annual total powers at the optimal angle outside the greenhouse and inside the greenhouse were 448.0 W and 398.7 W. The average annual total efficiencies at the optimal angle outside the greenhouse and inside the greenhouse were 40.8% and 56.9%. The total power in the greenhouse was lower by 49.3 W, while total efficiency in the greenhouse was higher by 16.1%.
引用
收藏
页码:400 / 412
页数:13
相关论文
共 50 条
  • [1] Annual Optimal Performance Analysis of Micro Heat Pipe PV/T under Different Angles in Northwest China
    LIU Xiaomin
    WU Qingbai
    LI Jinping
    Vojislav NOVAKOVIC
    Journal of Thermal Science, 2025, 34 (02) : 400 - 412
  • [2] Performance analysis of micro heat pipe PV/T within and outside the greenhouse in northwest China
    Li, Rui
    Zhai, Panpan
    Li, Jinping
    Liu, Ye
    Novakovic, Vojislavi
    ENERGY, 2024, 302
  • [3] Heat resistance analysis and performance improvement of an innovative micro heat pipe PV/T system
    Li, Rui
    Zhai, Panpan
    Cao, Yadong
    Li, Jinping
    Zhu, Juejie
    Novakovic, Vojislav
    ENERGY, 2025, 323
  • [4] Performance analysis of different flow rates and dust accumulation in micro heat pipe PV/T series system
    Li, Rui
    Jia, Zijiao
    Sun, Xiaohua
    Li, Jinping
    Zhai, Panpan
    Novakovic, Vojislav
    RENEWABLE ENERGY, 2025, 241
  • [5] Performance testing of a heat pipe PV/T heat pump system under different working modes
    Chen, Hongbing
    Niu, Haoyu
    Zhang, Lei
    Xiong, Yaxuan
    Zhai, Huixing
    Nie, Jinzhe
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2018, 13 (02) : 177 - 183
  • [6] Comparative and sensitive analysis of the annual performance between the conventional and the heat pipe PV/T systems
    Zhang, Tao
    Cai, Jingyong
    Zheng, Wenjie
    Zhang, Yufan
    Meng, Qingliang
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 28
  • [7] Performance analysis of a heat pipe PV/T system with different circulation tank capacities
    Zhang, Bingzhi
    Lv, Jian
    Yang, Hongxing
    Li, Tailu
    Ren, Shengfeng
    APPLIED THERMAL ENGINEERING, 2015, 87 : 89 - 97
  • [8] Performance analysis of an integrated solar-assisted heat pump system with heat pipe PV/T collectors operating under different weather conditions
    Huide, Fu
    Tao, Zhang
    8TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY (ICAE2016), 2017, 105 : 1143 - 1148
  • [9] Performance study and parametric analysis of a novel heat pipe PV/T system
    Pei Gang
    Fu Huide
    Zhu Huijuan
    Ji Jie
    ENERGY, 2012, 37 (01) : 384 - 395
  • [10] Annual analysis of heat pipe PV/T systems for domestic hot water and electricity production
    Pei Gang
    Fu Huide
    Ji Jie
    Chow Tin-tai
    Zhang Tao
    ENERGY CONVERSION AND MANAGEMENT, 2012, 56 : 8 - 21