Molecularly imprinted electrochemical sensor based on APTES-functionalized indium tin oxide electrode for the determination of sulfadiazine

被引:0
作者
Chopra, Samridhi [1 ,2 ]
Balkhandia, Manisha [1 ,2 ]
Khatak, Manisha [1 ,2 ]
Sagar, Navya [3 ]
Agrawal, Ved Varun [2 ]
机构
[1] Acad Sci & Innovat Res AcSIR, CSIR Human Resource Dev Ctr, CSIR HRDC Campus, Postal Staff Coll Area,Sector 19,Kamla Nehru Nagar, Ghaziabad 201002, Uttar Pradesh, India
[2] CSIR Natl Phys Lab, New Delhi 110012, India
[3] Amity Univ, Sect 125, Noida 201301, Uttar Pradesh, India
关键词
Molecularly imprinted polymer; Electrochemical sensor; Indium tin oxide (ITO) electrode; Sulfadiazine (SDZ); 3-aminopropyltriethoxysilane (APTES); Self-assembly; LIQUID-CHROMATOGRAPHY; SULFONAMIDES; MILK; POLYMERS; ANTIBIOTICS; VALIDATION; RESIDUES; EGG;
D O I
10.1007/s00604-024-06781-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical sensor was developed for the sensitive and selective detection of sulfadiazine (SDZ), based on a molecularly imprinted polymer (MIP) film formed on an indium tin oxide (ITO) electrode through a self-assembly process. The SDZ-imprinted ITO electrode (SDZ-MIP/APTES-ITO) was prepared through in situ polymerization using sulfadiazine, methacrylic acid (MAA), ethylene glycol dimethacrylate (EGDMA), and 2,2 '-azobisisobutyronitrile (AIBN) as the template, functional monomer, cross-linker, and initiator respectively. Before polymerization, the ITO electrode was functionalized with 3-aminopropyltriethoxysilane (APTES) to promote covalent attachment of the polymer to the electrode. After polymerization, the template molecule SDZ was removed to create selective recognition sites, forming the molecularly imprinted polymer electrode (MIP/APTES-ITO), which facilitates sulfadiazine detection. The sensor's performance was evaluated using cyclic and differential pulse voltammetry, demonstrating a linear response in the sulfadiazine concentration range 0.1 to 300 mu M, with a detection limit of 0.11 mu M. The MIP-based sensor exhibited good reproducibility, repeatability, selectivity, and stability in sulfadiazine detection. Its practical applicability was confirmed by the successful quantification of sulfadiazine in spiked milk samples.
引用
收藏
页数:13
相关论文
共 41 条
  • [1] Biomimetic catalysis at silicon centre using molecularly imprinted polymers
    Abbate, Vincenzo
    Bassindale, Alan R.
    Brandstadt, Kurt F.
    Taylor, Peter G.
    [J]. JOURNAL OF CATALYSIS, 2011, 284 (01) : 68 - 76
  • [2] Review-Recent Advancements in the Utilization of Indium Tin Oxide (ITO) in Electroanalysis without Surface Modification
    Akanda, Md. Rajibul
    Osman, Abdalghaffar Mohammad
    Nazal, Mazen Khaled
    Aziz, Md. Abdul
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (03)
  • [3] Molecularly imprinted polymers for drug delivery
    Alvarez-Lorenzo, C
    Concheiro, A
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 804 (01): : 231 - 245
  • [4] Tailoring the properties in conjugated copolymer P(EDOS-co-EDOT): Electrochemical polymerization and role of heteroatom
    Balkhandia, Manisha
    Kedia, Rashi
    Khatak, Manisha
    Chaudhary, Neeraj
    Patra, Asit
    [J]. ELECTROCHIMICA ACTA, 2023, 466
  • [5] Effects of the presence of sulfonamides in the environment and their influence on human health
    Baran, Wojciech
    Adamek, Ewa
    Ziemianska, Justyna
    Sobczak, Andrzej
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2011, 196 : 1 - 15
  • [6] Indirect Determination of Sulfadiazine by Cloud Point Extraction/Flow Injection-Flame Atomic Absorption (CPE/FI-FAAS) Spectrometry
    Dadfarnia, Shayessteh
    Hajishabani, All Mohammad
    Rad, Hamid Fazeli
    [J]. JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2011, 58 (04) : 503 - 508
  • [7] Environmental behavior and analysis of veterinary and human drugs in soils, sediments and sludge
    Díaz-Cruz, MS
    de Alda, MJL
    Barceló, D
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2003, 22 (06) : 340 - 351
  • [8] A ceria NPs decorated graphene nano-composite sensor for sulfadiazine determination in pharmaceutical formulation
    Ebrahimi, Mehrnaz
    Nikoofard, Hossein
    Faridbod, Farnoush
    Dezfuli, Amin Shiralizadeh
    Beigizadeh, Hana
    Norouzi, Parviz
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2017, 28 (22) : 16704 - 16712
  • [9] An Electrochemical Sensor for Sulfadiazine Determination Based on a Copper Nanoparticles/Molecularly Imprinted Overoxidized Polypyrrole Composite
    Elamin, Manahil Babiker
    Ali, Shazalia Mahmoud Ahmed
    Essousi, Houda
    Chrouda, Amani
    Alhaidari, Laila M. M.
    Jaffrezic-Renault, Nicole
    Barhoumi, Houcine
    [J]. SENSORS, 2023, 23 (03)
  • [10] Development and validation of a confirmatory method for the determination of sulphonamides in milk by liquid chromatography with diode array detection
    Gamba, Valentina
    Terzano, Chiara
    Fioroni, Laura
    Moretti, Simone
    Dusi, Guglielmo
    Galarini, Roberta
    [J]. ANALYTICA CHIMICA ACTA, 2009, 637 (1-2) : 18 - 23