Effect of CAD-CAM block thickness and translucency on the polymerization of luting materials

被引:4
作者
Kaya, Bengu Dogu [1 ]
Ozturk, Selinsu [2 ]
Senol, Ayse Asli [1 ]
Kahramanoglu, Erkut [3 ]
Atali, Pinar Yilmaz [1 ]
Tarcin, Bilge [1 ]
机构
[1] Marmara Univ, Fac Dent, Dept Restorat Dent, Istanbul, Turkiye
[2] Marmara Univ, Inst Hlth Sci, Dept Restorat Dent, Istanbul, Turkiye
[3] Marmara Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkiye
来源
BMC ORAL HEALTH | 2024年 / 24卷 / 01期
关键词
CAD-CAM block; Degree of conversion; Flowable resin composite; Luting material; Translucency; MECHANICAL-PROPERTIES; RESIN CEMENTS; CURING UNITS; CONVERSION; COMPOSITE; COLOR; OPALESCENCE; EFFICIENCY; OPACITY; ABILITY;
D O I
10.1186/s12903-024-05171-z
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim This in-vitro study aimed to evaluate the degree of conversion (DC) of dual-cured luting cement (Bifix QM, VOCO) and flowable composite (Grandio Flow, VOCO) under lithium disilicate glass-ceramic (IPS e.max CAD, Ivoclar Vivadent) and hybrid ceramic (Grandio Blocs, VOCO; Cerasmart, GC) CAD-CAM blocks with different thicknesses. Materials and methods Contrast ratio (CR), translucency (TPab, TP00), and opalescence (OP) parameters of 30 disc-shaped CAD-CAM blocks (n = 5) prepared with two different thicknesses (1.5 and 2 mm) and 8 mm diameters were calculated using a spectrophotometer (VITA Easyshade V, Zahnfabrik). A total of 36 Bifix QM and Grandio Flow samples were prepared at 100 mu m thickness using a specific setup by polymerizing from the top of the blocks. Following immersion in distilled water at 37 degrees C for 24 h, luting materials were examined by Fourier Transform Infrared Spectroscopy for DC calculation. Data were analyzed using One-way ANOVA, Kruskal Wallis, Mann Whitney U, and Independent Samples t-tests (p < 0.05). Results It was observed that, as the block thickness increased TPab, TP00, and OP decreased, while CR increased. There was no significant difference between the DC of Bifix QM and Grandio Flow when 1.5 mm blocks were used in all groups (p > 0.05). DC of Grandio Flow was significantly higher than Bifix QM under 2 mm-IPS e.max CAD (p = 0.011). Conclusion The translucency of the CAD-CAM blocks varies depending on their thickness. However, there was no significant difference in the DC of the luting materials depending on the block thickness. Further studies are needed on the use of flowable resin composites as luting material.
引用
收藏
页数:12
相关论文
共 50 条
[31]   Impact of CAD/CAM Material Thickness and Translucency on the Polymerization of Dual-Cure Resin Cement in Endocrowns [J].
Ikemoto, Soshi ;
Komagata, Yuya ;
Yoshii, Shinji ;
Masaki, Chihiro ;
Hosokawa, Ryuji ;
Ikeda, Hiroshi .
POLYMERS, 2024, 16 (05)
[32]   Grinding damage assessment for CAD-CAM restorative materials [J].
Curran, Philippe ;
Cattani-Lorente, Maria ;
Wiskott, H. W. Anselm ;
Durual, Stephane ;
Scherrer, Susanne S. .
DENTAL MATERIALS, 2017, 33 (03) :294-308
[33]   Wear resistance and abrasiveness of CAD-CAM monolithic materials [J].
Ludovichetti, Francesco Saverio ;
Trindade, Flavia Zardo ;
Werner, Arie ;
Kleverlaan, Cornelis Johannes ;
Fonseca, Renata Garcia .
JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (02)
[34]   Effect of erosive media on microhardness and fracture toughness of CAD-CAM dental materials [J].
Elraggal, Alaaeldin ;
Afifi, Rania ;
Abdelraheem, Islam .
BMC ORAL HEALTH, 2022, 22 (01)
[35]   Effect of machining damage on the surface roughness and flexural strength of CAD-CAM materials [J].
Redwan, Hetaf ;
Fan, Yuwei ;
Giordano II, Russell .
JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (03) :872-880
[36]   Translucency of CAD/CAM and 3D Printable Composite Materials for Permanent Dental Restorations [J].
Vichi, Alessandro ;
Balestra, Dario ;
Scotti, Nicola ;
Louca, Chris ;
Paolone, Gaetano .
POLYMERS, 2023, 15 (06)
[37]   Effect of accelerated staining and bleaching on chairside CAD/CAM materials with high and low translucency [J].
Gasparik, Cristina ;
Culic, Bogdan ;
Varvara, Mihai Adrian ;
Grecu, Alexandru ;
Burde, Alexandru ;
Dudea, Diana .
DENTAL MATERIALS JOURNAL, 2019, 38 (06) :987-993
[38]   Effect of the application of a hydrogen peroxide home bleaching agent on the cytotoxicity of different CAD-CAM restorative materials [J].
Ozverel, Cenk Serhan ;
Kurtulmus-Yilmaz, Sevcan .
DENTAL AND MEDICAL PROBLEMS, 2023, 60 (02) :311-320
[39]   Effect of different disinfection protocols on the surface properties of CAD-CAM denture base materials [J].
Atalay, Sevda ;
Cakmak, Gulce ;
Fonseca, Manrique ;
Schimmel, Martin ;
Yilmaz, Burak .
JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (05) :787-795
[40]   Effect of milling procedures in CAD-CAM systems on the color changes of CAD-CAM polymethyl methacrylate resin material as interim material [J].
Oyar, Perihan ;
Ulusoy, Mutahhar .
BMC ORAL HEALTH, 2024, 24 (01)