Diabetes is a non-communicable disease and people face many health issues due to diabetes. Worldwide, more than 500 million people have diabetes today. Currently, most devices measure blood glucose levels from a person’s blood, collected by pricking a fingertip. It is necessary for people with Type-1 diabetes to regularly check their blood glucose levels to prevent major health issues. Several times pricking a fingertip in a day feels very painful. This situation increases the demand for non-invasive blood glucose measurement devices, and a certain amount of research has been reported in recent years. This paper proposes a less complex, near infrared-based non-invasive device that measures glucose level continuously with higher accuracy. This paper also proposes a lightweight distributed architecture that utilizes the readings of the proposed device to estimate blood glucose level. The proposed architecture is validated using root mean square error (RMSE), mean absolute difference (MAD), and mean absolute relative difference (mARD) which are calculated as 6.08 mg/dL, 1.79 mg/dL, and 1.51%, respectively. © The Author(s), under exclusive licence to Springer Nature Singapore Pte Ltd. 2024.
引用
收藏
相关论文
共 38 条
[1]  
Holt R., Cockram C., Flyvbjerg A., Goldstein B., Text Book of Diadetes:Forth Edition., (2010)
[2]  
Vashist S., Continuous glucose Monitoring systems: a review, Diagnostics, 3, pp. 385-412, (2013)
[3]  
Facchinetti A., Continuous glucose monitoring sensors: past, present and future algorithmic challenges, Sens (Switzerland), 16, pp. 1-12, (2016)
[4]  
Singh A.K., Jha S.K., Fabrication and validation of a handheld noninvasive, optical biosensor for self-monitoring of glucose using saliva, IEEE Sens J, 19, pp. 8332-8339, (2019)
[5]  
Malik S., Khadgawat R., Anand S., Gupta S., Non-invasive detection of fasting blood glucose level via electrochemical measurement of saliva, Springerplus, 5, (2016)
[6]  
Prasad M.S., Chen R., Li Y., Rekha D., Li D., Ni H., Et al., Polypyrrole supported with Copper Nanoparticles Modified Alkali Anodized Steel Electrode for probing of glucose in real samples, IEEE Sens J, 18, pp. 5203-5212, (2018)
[7]  
Dai T., Adler A., In vivo blood characterization from bioimpedance spectroscopy of blood pooling, IEEE Trans Instrum Meas, 58, pp. 3831-3838, (2009)
[8]  
Song K., Ha U., Park S., Bae J., Yoo H.J., An impedance and Multi-wavelength Near-Infrared spectroscopy IC for non-invasive blood glucose estimation, IEEE J Solid-State Circuits, 50, pp. 1025-1037, (2015)
[9]  
Cherkasova O., Nazarov M., Shkurinov A., Noninvasive blood glucose monitoring in the terahertz frequency range, Opt Quantum Electron, 48, (2016)
[10]  
Pai P.P., De A., Banerjee S., Accuracy enhancement for noninvasive glucose estimation using dual-wavelength photoacoustic measurements and kernel-based calibration, IEEE Trans Instrum Meas, 67, pp. 126-135, (2018)