Synthesis and characterization of a composite featuring metal-organic frameworks, titania nanoparticles, and graphene oxide: a dual evaluation as a photocatalyst and electrochemical sensing platform

被引:0
作者
Bhatnagar, Varun [1 ]
Kumar, Deepak [1 ]
Pandey, Anjana [2 ]
Pandey, Ashutosh [1 ]
机构
[1] Motilal Nehru Natl Inst Technol Allahabad, Dept Chem, Prayagraj 211004, India
[2] Motilal Nehru Natl Inst Technol Allahabad, Dept Biotechnol, Prayagraj 211004, India
关键词
photocatalytic activity; methylene blue dye; electrochemical sensor; graphene oxide; imatinib; GO@HKUST-1@TiO2 composite; IMATINIB MESYLATE; SENSITIVE DETERMINATION; SEMICONDUCTOR PHOTOCATALYSTS; DRUG IMATINIB; HUMAN PLASMA; SQUARE-WAVE; PERFORMANCE; URINE; NANOCOMPOSITE; VOLTAMMETRY;
D O I
10.1007/s12039-024-02320-3
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This investigation involves synthesizing a new composite, blending graphene oxide (GO), HKUST-1 (copper-based metal-organic frameworks), and titanium dioxide (TiO2) via the hydrothermal method. Following that, the prepared composite is utilized in the design of a photocatalyst and electrochemical sensing platform. Numerous analytical methods, such as XRD, FT-IR, SEM-EDX, TGA, UV-Vis investigations, and suitable electrochemical analyses, were used to examine the morphological and structural characteristics of the crafted material. The tailored composite exhibited remarkable efficiency, showcasing an exceptional degradation efficiency of 97.47% for MB dye within just an hour under sunlight irradiation. On the other hand, the electrochemical sensor developed by fabricating the surface of a glassy carbon electrode (GCE) referred to as GO@HKUST-1@TiO2 /GCE exhibited a remarkable catalytic effect on the electrochemical response to imatinib (IMB). The sensor displayed exceptional electrocatalytic performance for detecting IMB under optimized conditions, including solution pH and scan rate. Calibration plots showed linear segments within the concentration range of 2-20 mu M, with a significant limit of detection (LOD). The fabricated sensor demonstrated high accuracy, reproducibility, and stability throughout various electrochemical assessments. Thus, the dual functionality of the material has been established. Graphical abstractA novel composite comprising graphene oxide (GO), HKUST-1, and titanium dioxide (TiO2) namely GO@HKUST@TiO(2 )was synthesized and utilized for both photocatalytic degradation of methylene blue (MB) dye and electrochemical sensing of imatinib (IMB). The composite demonstrated exceptional efficiency in both applications, highlighting its potential for dual-functionality.
引用
收藏
页数:19
相关论文
共 63 条
[1]  
Ahmed J, 2022, Chemistry Environ Se, V5, P1
[2]   Capillary electrophoresis method for plasmatic determination of imatinib mesylate in chronic myeloid leukemia patients [J].
Ajimura, Tatiana O. ;
Borges, Keyller B. ;
Ferreira, Aline F. ;
de Castro, Fabiola A. ;
de Gaitani, Cristiane M. .
ELECTROPHORESIS, 2011, 32 (14) :1885-1892
[3]   Graphene oxide based semiconductor photocatalysts for degradation of organic dye in waste water: A review on fabrication, performance enhancement and challenges [J].
Al Kausor, Mehdi ;
Chakrabortty, Dhruba .
INORGANIC CHEMISTRY COMMUNICATIONS, 2021, 129
[4]   A critical review on the treatment of dye-containing wastewater: Ecotoxicological and health concerns of textile dyes and possible remediation approaches for environmental safety [J].
Al-Tohamy, Rania ;
Ali, Sameh S. ;
Li, Fanghua ;
Okasha, Kamal M. ;
Mahmoud, Yehia A. -G. ;
Elsamahy, Tamer ;
Jiao, Haixin ;
Fu, Yinyi ;
Sun, Jianzhong .
ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2022, 231
[5]   Photocatalytic and Glucose Sensing Properties of ZnO-Based Nanocoating [J].
Bakranova, Dina ;
Seitov, Bekbolat ;
Bakranov, Nurlan .
CHEMENGINEERING, 2023, 7 (02)
[6]   Functionalization effects on HKUST-1 and HKUST-1/graphene oxide hybrid adsorbents for hydrogen sulfide removal [J].
Bhoria, Nidhika ;
Basina, Georgia ;
Pokhrel, Jeewan ;
Reddy, K. Suresh Kumar ;
Anastasiou, Stavroula ;
Balasubramanian, Vaithilingam V. ;
AlWahedi, Yasser Fowad ;
Karanikolos, Georgios N. .
JOURNAL OF HAZARDOUS MATERIALS, 2020, 394
[7]   Sensitive determination of anticancer drug imatinib in spiked human urine samples by differential pulse voltammetry on anodically pretreated boron-doped diamond electrode [J].
Brycht, Mariola ;
Kaczmarska, Kinga ;
Uslu, Bengi ;
Ozkan, Sibel A. ;
Skrzypek, Slawomira .
DIAMOND AND RELATED MATERIALS, 2016, 68 :13-22
[8]   In Situ Hydrothermal Growth of Metal-Organic Framework 199 Films on Stainless Steel Fibers for Solid-Phase Microextraction of Gaseous Benzene Homologues [J].
Cui, Xiao-Yan ;
Gu, Zhi-Yuan ;
Jiang, Dong-Qing ;
Li, Yan ;
Wang, He-Fang ;
Yan, Xiu-Ping .
ANALYTICAL CHEMISTRY, 2009, 81 (23) :9771-9777
[9]  
Cullity B D., 1978, Elements of X-ray diffraction, P127
[10]  
Dagher R, 2002, CLIN CANCER RES, V8, P3034