Taurolidine-containing solution for reducing cardiac implantable electronic device infection-early report from the European TauroPace™ registry

被引:0
作者
Vonthein, Reinhard [1 ]
Baldauf, Benito [2 ,3 ]
Borov, Stefan [3 ,4 ]
Lau, Ernest W. [5 ]
Giaccardi, Marzia [6 ]
Assadian, Ojan [7 ,8 ]
Haddad, Christelle [9 ]
Chevalier, Philippe [9 ]
Bode, Kerstin [10 ]
Foley, Paul [11 ]
Thomas, Honey [12 ]
Campbell, Niall G. [13 ]
Fichtner, Stephanie [14 ]
Donazzan, Luca [15 ]
Pescoller, Felix [15 ]
Oberhollenzer, Rainer [15 ]
Cemin, Roberto [15 ]
Bonnemeier, Hendrik [2 ,3 ]
机构
[1] Univ Lubeck, Inst Med Biometrie & Stat, Ratzeburger Allee 160, D-23562 Lubeck, Germany
[2] Univ Appl Sci Bremerhaven, Hsch Bremerhaven, Inst Life Sci, Karlstadt 8, D-27568 Bremerhaven, Germany
[3] Univ Kiel, Med Fac, Christian Albrechts Pl 4, D-24118 Kiel, Germany
[4] Klinikum Freising, Dept Cardiol, Alois Steinecker Str 18, D-85354 Freising Weihenstephan, Germany
[5] Royal Victoria Hosp, Dept Cardiol, Grosvenor Rd, Belfast BT12 6BA, North Ireland
[6] Osped Santa Maria Annunziata, Dept Cardiol, I-50012 Florence, Italy
[7] Reg Hosp Wiener Neustadt, Corvinusring 3-5, A-2700 Wiener Neustadt, Austria
[8] Univ Huddersfield, Inst Skin Integr & Infect Prevent, Sch Human & Hlth Sci, Huddersfield HD1 3DH, England
[9] Hop Louis Pradel, Dept Radiol, 59 Bd Pinel, F-69500 Bron, France
[10] Herzzentrum Leipzig, Dept Electropyhsiol, Strumpellstr 39, D-04289 Leipzig, Germany
[11] Great Western NHS Fdn Trust, Dept Cardiol, Marlborough Rd, Swindon SN3 6BB, England
[12] Northumbria Healthcare NHS Fdn Trust, Dept Cardiol, Ashington NE63 9JJ, Northd, England
[13] Univ Manchester, Manchester Acad Hlth Sci Ctr, Sch Med Sci, Div Cardiovasc Sci, Manchester, England
[14] Krankenhaus Landshut Achdorf, Dept Cardiol, Achdorfer Weg 5, D-84036 Landshut, Germany
[15] Osped Reg San Maurizio, Dept Cardiol, Via Lorenz Bohler 5, I-39100 Bolzano, Italy
关键词
Surgical site infection; Antimicrobial compound; Permanent pacemaker; Subcutaneous implantable cardioverter defibrillator; Cardiac resynchronization therapy; Cardiac contractility modulation; Taurolidine; UNITED-STATES; CARDIOVERTER-DEFIBRILLATORS; ANTIBIOTIC-PROPHYLAXIS; PARENTERAL-NUTRITION; RISK-FACTORS; PREVENTION; RATES; ASSOCIATION; PACEMAKERS; SOCIETY;
D O I
10.1186/s13019-024-03059-1
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
IntroductionInfection is a significant complication of cardiac implantable electronic device (CIED) therapy. The European TauroPace (TM) Registry investigates the safety and efficacy of TauroPace (TM) (TP), an antimicrobial solution containing taurolidine, designed to prevent CIED infections.MethodsThis multicenter study included patients undergoing CIED procedures at participating centers where TP was used as a disinfectant for external hardware surfaces and an antiseptic for irrigating surgical sites. All patients eligible for CIED placement with adjunctive TP as the standard of care were included. Other aspects of CIED procedures adhered to current guidelines. Data on CIED-related infective endocarditis, CIED pocket infection, device and procedure-related complications, adverse events, and all-cause mortality were prospectively collected for 12 months. In cases of revision, the previous procedure was censored, and a new procedure was created. Binomial and Kaplan-Meier statistics were employed to analyze event rates.ResultsFrom January 2020 to November 2022, TP was used in 822 out of 1170 CIED procedures. Among patients who completed the 3-month follow-up, no CIED pocket infections were observed, and one case of CIED-related infective endocarditis was reported. In the 12-month follow-up cohort, two additional local pocket CIED infections were observed, resulting in a total of three major CIED infections within 1 year after the CIED placement procedure. The 3-month and 12-month major CIED infection rates were 0.125% and 0.51%, respectively. During the observation a complication rate of 4.4% was reported. No adverse events related to TP were observed.ConclusionsTP appears to be effective and safe in preventing CIED infections.ClinicalTrials.gov Identifier: NCT04735666.ConclusionsTP appears to be effective and safe in preventing CIED infections.ClinicalTrials.gov Identifier: NCT04735666.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Update on Cardiovascular Implantable Electronic Device Infections and Their Prevention, Diagnosis, and Management: A Scientific Statement From the American Heart Association: Endorsed by the International Society for Cardiovascular Infectious Diseases
    Baddour, Larry M.
    Esquer Garrigos, Zerelda
    Rizwan Sohail, M.
    Havers-Borgersen, Eva
    Krahn, Andrew D.
    Chu, Vivian H.
    Radke, Connie S.
    Avari-Silva, Jennifer
    El-Chami, Mikhael F.
    Miro, Jose M.
    Desimone, Daniel C.
    [J]. CIRCULATION, 2024, 149 (02) : e201 - e216
  • [2] An unusual cause of inappropriate shocks delivered by an implantable cardioverter defibrillator
    Baldauf, Benito
    Lau, Ernest W.
    Giaccardi, Marzia
    Bonnemeier, Hendrik
    [J]. BMC CARDIOVASCULAR DISORDERS, 2024, 24 (01):
  • [3] Baldauf BJ., 2024, EP Europace, V26, peuae102
  • [4] Risk Factors for Infections Involving Cardiac Implanted Electronic Devices
    Birnie, David H.
    Wang, Jia
    Alings, Marco
    Philippon, Francois
    Parkash, Ratika
    Manlucu, Jaimie
    Angaran, Paul
    Rinne, Claus
    Coutu, Benoit
    Low, R. Aaron
    Essebag, Vidal
    Morillo, Carlos
    Redfearn, Damian
    Toal, Satish
    Becker, Giuliano
    Degrace, Michel
    Thibault, Bernard
    Crystal, Eugene
    Tung, Stanley
    LeMaitre, John
    Sultan, Omar
    Bennett, Matthew
    Bashir, Jamil
    Ayala-Paredes, Felix
    Gervais, Philippe
    Rioux, Leon
    Hemels, Martin E. W.
    Bouwels, Leon H. R.
    Exner, Derek V.
    Dorian, Paul
    Connolly, Stuart J.
    Longtin, Yves
    Krahn, Andrew D.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (23) : 2845 - 2854
  • [6] European Heart Rhythm Association (EHRA) international consensus document on how to prevent, diagnose, and treat cardiac implantable electronic device infections-endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), the Latin American Heart Rhythm Society (LAHRS), International Society for Cardiovascular Infectious Diseases (ISCVID) and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS)
    Blomstrom-Lundqvist, Carina
    Traykov, Vassil
    Erba, Paola Anna
    Burri, Haran
    Nielsen, Jens Cosedis
    Bongiorni, Maria Grazia
    Poole, Jeanne
    Boriani, Giuseppe
    Costa, Roberto
    Deharo, Jean-Claude
    Epstein, Laurence M.
    Saghy, Laszlo
    Snygg-Martin, Ulrika
    Starck, Christoph
    Tascini, Carlo
    Strathmore, Neil
    [J]. EUROPACE, 2020, 22 (04): : 515 - 516
  • [7] Salvage of infected cardiac implantable electronic device with taurolidine-a case report
    Borov, Stefan
    Baldauf, Benito
    Lau, Ernest W.
    Bonnemeier, Hendrik
    [J]. CARDIOTHORACIC SURGEON, 2022, 30 (01)
  • [8] Using Detachment-Promoting Agents for the Prevention of Chronic Peritoneal Dialysis-Associated Infections
    Branger, Bernard
    Marion, Karine
    Bergeron, Emmanuelle
    Perret, Cecile
    Zabadani, Bachir
    Reboul, Pascal
    Freney, Jean
    [J]. ARTIFICIAL ORGANS, 2008, 32 (12) : 918 - 924
  • [9] Antibiotic prophylaxis for permanent pacemaker implantation - A meta-analysis
    Da Costa, A
    Kirkorian, G
    Cucherat, M
    Delahaye, F
    Chevalier, P
    Cerisier, A
    Isaaz, K
    Touboul, P
    [J]. CIRCULATION, 1998, 97 (18) : 1796 - 1801
  • [10] Efficacy of Antibiotic Prophylaxis Before the Implantation of Pacemakers and Cardioverter-Defibrillators Results of a Large, Prospective, Randomized, Double-Blinded, Placebo-Controlled Trial
    de Oliveira, Julio Cesar
    Martinelli, Martino
    D'Orio Nishioka, Silvana Angelina
    Varejao, Tania
    Uipe, David
    Andrade Pedrosa, Anisio Alexandre
    Costa, Roberto
    Danik, Stephan B.
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2009, 2 (01) : 29 - 34