Possibilities and limitations of computer assisted chiral HPLC method development for ozanimod on polysaccharide based chiral stationary phases

被引:1
作者
Ferencz, Elek [1 ]
Szabo, Zoltan-Istvan [1 ,2 ]
Zoldhegyi, Arnold [3 ]
Dombi, Gergely [4 ,5 ]
Molnar, Gergely [4 ,5 ]
Dobo, Mate [4 ,5 ]
Varga, Erzsebet [1 ]
Molnar, Imre [3 ]
Toth, Gergo [4 ,5 ]
机构
[1] George Emil Palade Univ Med Pharm Sci & Technol T, Targu Mures, Romania
[2] Sz imfidum Ltd, Lunga 525401, Romania
[3] Molnar Inst Appl Chromatog, Berlin, Germany
[4] Semmelweis Univ, Dept Pharmaceut Chem, Hogyes E u 9, H-1092 Budapest, Hungary
[5] Semmelweis Univ, Ctr Pharmacol & Drug Res & Dev, Budapest, Hungary
关键词
Ozanimod; Chiral separation; Polysaccharide-type chiral column; AQbD; DryLab; Computer-assisted method development; CHROMATOGRAPHIC METHOD DEVELOPMENT; CATION-EXCHANGE CHROMATOGRAPHY; ANTIBODY CHARGE VARIANTS; SEPARATION; SIMULATION; EFFICACY; BEHAVIOR; FORMS; DRUG;
D O I
10.1038/s41598-024-78415-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In this study, a direct HPLC method was developed to determine the enantiomeric purity of the immunomodulatory drug, ozanimod. A systematic method development process was followed, incorporating risk assessment, identification of critical analytical procedure parameters, initial screening of stationary phases, and software-assisted optimization of method parameters. Eight different polysaccharide-based chiral columns were selected to assess chiral separation of enantiomers under polar organic elution mode. The most promising results were obtained using a methanol:2-propanol mixture on the amylose-based Chiralpak AD column. Following this, systematic modeling was conducted using DryLab software to optimize method conditions, including isocratic eluent composition, temperature, and flow rate. Baseline separation was achieved within fifteen minutes using the optimized parameters: Chiralpak AD column thermostated at 10 degrees C, and a mobile phase of methanol:2-propanol: diethylamine, 70:30:0.1 (v/v/v %), delivered at a flow rate of 0.8 mL/min. The developed method was validated according to current guidelines and in silico robustness testing was conducted to determine tolerance limits for critical separation parameters and their impact on enantioresolution. Our findings demonstrate the utility of DryLab, typically employed for reversed-phase achiral separations, in optimizing chiral methods even in polar organic mode. Limitations of the selected approach the development of chiral separation methods are also highlighted.
引用
收藏
页数:12
相关论文
共 48 条
[1]  
[Anonymous], 2022, PHARM 2022, DOI DOI 10.3390/PH15020240
[2]  
[Anonymous], 2024, J CHROMATOGR A, DOI DOI 10.1016/J.CHROMA.2024.464660
[3]  
Baczek T., 2001, LCGC EUROPE, V2
[4]   Analysis of recombinant monoclonal antibodies in hydrophilic interaction chromatography: A generic method development approach [J].
Bobaly, Balazs ;
D'Atri, Valentina ;
Beck, Alain ;
Guillarme, Davy ;
Fekete, Szabolcs .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2017, 145 :24-32
[5]  
Buchlovic M., 2019, Patent, Patent No. [US11390593B2, 11390593]
[6]   Recent trends in preparation, investigation and application of polysaccharide-based chiral stationary phases for separation of enantiomers in high-performance liquid chromatography [J].
Chankvetadze, Bezhan .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2020, 122
[7]   Enantioselective Synthesis of Ozanimod, the Active Pharmaceutical Ingredient of a New Drug for Multiple Sclerosis [J].
Cianferotti, Claudio ;
Barreca, Giuseppe ;
Bollabathini, Venkatesh ;
Carcone, Luca ;
Grainger, Damian ;
Staniland, Samantha ;
Taddei, Maurizio .
EUROPEAN JOURNAL OF ORGANIC CHEMISTRY, 2021, 2021 (12) :1924-1930
[8]   Is hydrophobic interaction chromatography the most suitable technique to characterize site-specific antibody-drug conjugates? [J].
D'Atri, Valentina ;
Pell, Reinhard ;
Clarke, Adrian ;
Guillarme, Davy ;
Fekete, Szabolcs .
JOURNAL OF CHROMATOGRAPHY A, 2019, 1586 :149-153
[9]   Molecular Dynamics Simulations of Amylose- and Cellulose-Based Selectors and Related Enantioseparations in Liquid Phase Chromatography [J].
Dallocchio, Roberto ;
Dessi, Alessandro ;
Sechi, Barbara ;
Peluso, Paola .
MOLECULES, 2023, 28 (21)
[10]   Simultaneous Determination of Enantiomeric Purity and Organic Impurities of Dexketoprofen Using Reversed-Phase Liquid Chromatography-Enhancing Enantioselectivity through Hysteretic Behavior and Temperature-Dependent Enantiomer Elution Order Reversal on Polysaccharide Chiral Stationary Phases [J].
Dobo, Mate ;
Dombi, Gergely ;
Koteles, Istvan ;
Fiser, Bela ;
Kis, Csenge ;
Szabo, Zoltan-Istvan ;
Toth, Gergo .
INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2024, 25 (05)