Superior biomechanical stability of pedicle screws compared to lateral mass screws: recommendations for bicortical positioning and enhancing bone contact in geriatric C1 vertebrae

被引:0
作者
Leonhardt, Leon-Gordian [1 ]
Roerup, Leonie [1 ]
Kammal, Anna Lena [2 ]
Hahn, Michael [3 ]
Dreimann, Marc [1 ]
Ondruschka, Benjamin [2 ]
von Brackel, Felix Nikolai [3 ]
Rolvien, Tim [1 ]
Viezens, Lennart [1 ]
von Kroge, Simon [1 ,3 ]
机构
[1] Univ Med Ctr Hamburg Eppendorf, Dept Trauma & Orthopaed Surg, Martinistr 52, D-20246 Hamburg, Germany
[2] Univ Med Ctr Hamburg Eppendorf, Inst Legal Med, Butenfeld 34, D-22529 Hamburg, Germany
[3] Univ Med Ctr Hamburg Eppendorf, Dept Osteol & Biomech, Lottestr 59, D-22529 Hamburg, Germany
来源
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH | 2025年 / 20卷 / 01期
关键词
Cervical spine surgery; Lateral mass screw; Pedicle screw; Mechanical testing; C1; Bone microstructure; FIXATION; PLACEMENT; FRACTURES; DENSITY; ZONES; ATLAS; OLDER; AGE;
D O I
10.1186/s13018-025-05472-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundIn atlantoaxial instabilities, posterior C1/C2 fusion using lateral mass screws (LMS) or pedicle screws (PS) in a mono- or bicortical position in the atlas is a typical treatment. The bone microstructure and positioning of the screw trajectories appear to be of significant relevance for stability.PurposeThe aim of this study was a comparative analysis of the mechanical durability of screw fixation concerning microstructural characteristics of the trajectories of LMS and PS in mono- and bicortical position.MethodsHuman C1 from geriatric body donors (n = 28; 50% female, age 80.8 +/- 13.9 years) were collected and characterized based on their bone microstructure. Additionally, the mechanical stability of LMS and PS fixation in mono- and bicortical positioning was tested by mechanical loading. High-resolution quantitative computed tomography was used to analyze the bone microstructure of cylinders corresponding to the trajectories of PS and LMS in mono- and bicortical locations in each C1. After instrumentation with both screw types and types of fixation, the mechanical stability was tested by increased cyclic loading in cranio-caudal direction.ResultsTrajectories of PS presented with more bone volume and a higher contact length to cortical bone. Simultaneously, a higher number of cycles and a higher maximum force was needed to loosen PS compared to LMS, while the loose by torque at the experiment end was still greater in PS. Differences between mono- and bicortical positioning of PS and LMS have only been observed in the initial stiffness of screws. When comparing microstructural and mechanical properties, the cortical contact length and bone volume in screw trajectories were strongest associated with a high loose and cycle count.ConclusionsThis study suggests that mono- and bicortical positioning of PS is similarly efficient in creating a stable basis for screw fixation in the atlas. While PS are superior to LMS, the contact with cortical bone is of major relevance for a stable foundation.
引用
收藏
页数:11
相关论文
共 21 条
  • [1] Regional variations in C1-C2 bone density on quantitated computed tomography and clinical implications
    Baisden, Jamie L.
    Varghese, Vicky
    Banerjee, Anjishnu
    Yoganandan, Narayan
    [J]. NORTH AMERICAN SPINE SOCIETY JOURNAL, 2023, 14
  • [2] C1 anatomy and dimensions relative to lateral mass screw placement
    Christensen, David M.
    Eastlack, Robert K.
    Lynch, James J.
    Yaszemski, Michael J.
    Currier, Bradford L.
    [J]. SPINE, 2007, 32 (08) : 844 - 848
  • [3] Anterior fixation of odontoid fractures in an elderly population Clinical article
    Dailey, Andrew T.
    Hart, David
    Finn, Michael A.
    Schmidt, Meic H.
    Apfelbaum, Ronald I.
    [J]. JOURNAL OF NEUROSURGERY-SPINE, 2010, 12 (01) : 1 - 8
  • [4] Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis
    Dickman, CA
    Sonntag, VKH
    [J]. NEUROSURGERY, 1998, 43 (02) : 275 - 280
  • [5] Biomechanical comparison of unicortical versus bicortical C1 lateral mass screw fixation
    Eck, Jason C.
    Walker, Matt P.
    Currier, Bradord L.
    Chen, Qingshan
    Yaszemski, Michael J.
    An, Kai-Nan
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2007, 20 (07): : 505 - 508
  • [6] Biomechanical advantage of C1 pedicle screws over C1 lateral mass screws: a cadaveric study
    Fensky, Florian
    Kueny, Rebecca A.
    Sellenschloh, Kay
    Pueschel, Klaus
    Morlock, Michael M.
    Rueger, Johannes M.
    Lehmann, Wolfgang
    Huber, Gerd
    Hansen-Algenstaedt, Nils
    [J]. EUROPEAN SPINE JOURNAL, 2014, 23 (04) : 724 - 731
  • [7] Evaluation of anatomic landmarks and safe zones for screw placement in the atlas via the posterior arch
    Gebauer, Matthias
    Barvencik, Florian
    Briem, Daniel
    Kolb, Jan P.
    Seitz, Sebastian
    Rueger, Johannes M.
    Pueschel, Klaus
    Amling, Michael
    [J]. EUROPEAN SPINE JOURNAL, 2010, 19 (01) : 85 - 90
  • [8] Posterior C1-C2 fusion with polyaxial screw and rod fixation
    Harms, J
    Melcher, RP
    [J]. SPINE, 2001, 26 (22) : 2467 - 2471
  • [9] Improving stability of atlantoaxial fusion: a biomechanical study
    Kussmaul, Adrian Cavalcanti
    Kuehlein, Titus
    Greiner, Axel
    Walter, Sandy
    Becker, Christopher A.
    Kistler, Manuel
    Rubenbauer, Bianka
    Andress, Sebastian
    Boecker, Wolfgang
    Bruder, Jan
    [J]. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2023, 33 (06) : 2497 - 2503
  • [10] Cervical spine injuries in patients 65 years old and older: Epidemiologic analysis regarding the effects of age and injury mechanism on distribution, type, and stability of injuries
    Lomoschitz, FM
    Blackmore, CC
    Mirza, SK
    Mann, FA
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (03) : 573 - 577