Retention of CAD-CAM locator retentive attachment insert in mandibular implant overdenture

被引:0
作者
Diab, Mai Hassan [1 ]
Abdelaziz, Medhat Sameh [2 ]
Eldin, Mohamed Hatem Kamal [1 ]
机构
[1] October 6 Univ, Fac Dent, Removable Prosthodont Dept, Giza, Egypt
[2] Future Univ Egypt, Fac Oral & Dent Med, Prosthodont Dept, Cairo, Egypt
关键词
Computer; Aided design; Denture precision attachment; Dental implantation; Denture retention; WEAR;
D O I
10.1186/s12903-025-05434-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundThe continuous development in digital prosthodontics allowed the customization of attachments and retentive inserts which offers an easy and cheap solution for regular maintenance of locator overdentures during daily practice. The present study compared the change in retention values of the fully digitally manufactured custom-made locator attachment retentive insert with the ready-made ones after insertion, removal, and masticatory cycles.MethodsA complete denture was constructed over a mandibular edentulous epoxy model. Two implants were inserted into the model between the laterals and canines following the prosthetically driven implant protocol. Locator retentive attachment inserts were digitally designed using free-form modeling software and milled from PEEK (Poly Ether Ether Ketone). After the pick-up of the ready- and custom-made retentive inserts, an insertion, removal, and masticatory cycles test simulating 1 year of patient usage was performed. The change in retention values was recorded at baseline, 6 months, and after one year of simulated clinical use. An independent sample t-test was used to compare the data between the two studied groups.ResultsThere were statistically significant differences in retention values between the custom-made and ready-made locator inserts at baseline and after 6 months. (p = 0.001*). On the other hand, there was no significant difference in retention after 1 year of simulated use. (p = 0.083, NS)ConclusionsThe custom-made milled locator retentive attachment insert can be used as an alternative to the ready-made one due to their comparable retention values after 1 year of simulated use.
引用
收藏
页数:8
相关论文
共 33 条
[1]   Digital design and manufacture of a stackable implant surgical guide for immediate loading in completely edentulous full-arch cases: a dental technique [J].
Abdelaziz, Medhat Sameh ;
Tella, Eman Abd El Sattar Abd El Megid .
QUINTESSENCE INTERNATIONAL, 2023, 54 (09) :750-755
[2]   Digital fabrication of polyetheretherketone retentive bar attachment inserts as overdenture maintenance: A dental technique [J].
Abdelaziz, Medhat Sameh ;
Tella, Eman Abd El Sattar Abd El Megid .
JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (06) :1034-1037
[3]   Retention of Different Attachment Systems for Digitally Designed Mandibular Implant Overdenture [J].
Abdelaziz, Medhat Sameh ;
Fawzy, Aya Mohamed ;
Ghali, Rami Maher ;
Nassar, Hossam, I .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (02) :162-169
[4]   Influence of different materials on retention behavior of CAD-CAM fabricated bar attachments [J].
Abdelrehim, Aly ;
Abdelhakim, Ahmed ;
ElDakkak, Sherif .
JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (04) :765-775
[5]   Milled Bar with PEEK and Metal Housings for Inclined Implants Supporting Mandibular Overdentures: 1-Year Clinical, Prosthetic, and Patient-Based Outcomes [J].
Abdraboh, Abdelrahman Elsaid ;
Elsyad, Moustafa Abdou ;
Mourad, Samah Ibrahim ;
Alameldeen, Hesham Ebrahim .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (05) :982-989
[6]  
[Anonymous], 2017, J Prosthet Dent, V117, pe1, DOI 10.1016/j.prosdent.2016.12.001
[7]  
Bayer S, 2007, QUINTESSENCE INT, V38, pE229
[8]   Retention force of plastic clips on implant bars: a randomized controlled trial [J].
Bayer, Stefan ;
Komor, Nathalie ;
Kramer, Annina ;
Albrecht, Dominic ;
Mericske-Stern, Regina ;
Enkling, Norbert .
CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (12) :1377-1384
[9]   Retention force and fatigue strength of overdenture attachment systems [J].
Botega, DM ;
Mesquita, MF ;
Henriques, GEP ;
Vaz, LG .
JOURNAL OF ORAL REHABILITATION, 2004, 31 (09) :884-889
[10]   Retentive Properties of Two Stud Attachments with Polyetherketoneketone or Nylon Insert in Mandibular Implant Overdentures [J].
Choi, Jae-Won ;
Yun, Bo-Hyeok ;
Jeong, Chang-Mo ;
Huh, Jung-Bo .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (05) :1079-1088