The effect of various denture cleansers on the physical and mechanical properties of CAD/CAM and heat-polymerized denture base materials: an in vitro study

被引:0
|
作者
Selin, Ozyurt Tekin [1 ]
Ipek, Caglar [1 ]
机构
[1] Recep Tayyip Erdogan Univ, Fac Dent, Dept Prosthodont, Menderes Blvd 612 Rize, TR-53020 Rize, Turkiye
关键词
Acrylic resin; CAD/CAM; Denture bases; Denture cleansers; Flexural strength; FABRICATING COMPLETE DENTURES; SURFACE-ROUGHNESS; CHEMICAL DISINFECTION; ACRYLIC RESINS; MICROWAVE; IMMERSION; HARDNESS; COLOR;
D O I
10.1007/s00784-024-06016-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectivesTo investigate the effects of denture cleansers on the various properties of CAD/CAM and heat-polymerized polymethyl methacrylate (PMMA). Materials and methodsTwo different brands of heat-polymerized and two of milled PMMA were fabricated (n = 50), in total 200. Each group was randomly divided into five subgroups (n = 10): control groups (D1) kept in distilled water, cleaning tablets (D2, D3), neutral (D4) and acidic electrolyzed acid water (EAW) (D5). Surface roughness, hardness and flexural strength values were evaluated. Data were statistically analyzed with two-way ANOVA and Tukey post hoc test for comparison (p<0.05). ResultsThe milled group showed significantly lower surface roughness, greater surface hardness, and higher flexural strength values than heat polymerized denture bases (p<0.05). The denture cleansers had no significant effect on the surface roughness values of the milled specimens (p>0.05), whereas the specimens in the heat-polymerized groups and treated with D5 showed greater surface roughness values compared with the other cleaning agents (p > 0.05). The denture cleansers had no significant effect on surface hardness and flexural strength of heat polymerize groups (p > 0.05). However, D2, D3 and D5 cleaning agent decreased the hardness values of the milled group (p<0.05) and D5 cleaning agent decreased the flexural strength of the milled group (p<0.05). ConclusionsIt was observed that the applied denture cleansers affected the surface roughness, surface hardness, and flexural strength values of both denture bases but within a clinically acceptable value. Clinical RelevanceCAD/CAM denture bases showed significantly higher physical and mechanical properties than to heat-polymerized base materials. Although the applied neutral EAW cleaners give desired results for denture bases, clinical studies are needed for biological compatibility.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Effect of denture cleansers on physical properties of heat-polymerized acrylic resin
    Peracini, Amanda
    Davi, Leticia Resende
    Ribeiro, Nathalia de Queiroz
    de Souza, Raphael Freitas
    Lovato da Silva, Claudia Helena
    Oliveira Paranhos, Helena de Freitas
    JOURNAL OF PROSTHODONTIC RESEARCH, 2010, 54 (02) : 78 - 83
  • [2] Polymeric additions effect on mechanical properties of heat-polymerized denture base resin: an in vitro study
    Ibrahim Hamad Alfahdawi
    Discover Materials, 5 (1):
  • [3] Effect of ethanol treatment on mechanical properties of heat-polymerized polymethyl methacrylate denture base polymer
    Basavarajappa, Santhosh
    Abdullah Alkheraif, Abdul Aziz
    Alhijji, Saleh M.
    Matinlinna, Jukka Pekka
    Vallittu, Pekka Kalevi
    DENTAL MATERIALS JOURNAL, 2017, 36 (06) : 834 - 841
  • [4] Effect of cigarette smoke and denture cleansers on the surface properties and color stability of CAD-CAM and conventional denture base resins
    Aydogan Ayaz, Elif
    Ustun Aladag, Seda
    DENTAL MATERIALS JOURNAL, 2023, 42 (02) : 167 - 176
  • [5] Evaluation of different surface treatments on the bond strength of CAD/CAM PMMA denture teeth to heat-polymerized acrylic denture base
    Alhomsi, Nour Alhouda
    Almustafa, Ammar
    Alzoubi, Hasan
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [6] Impact of different chemical denture cleansers on the properties of digitally fabricated denture base resin materials
    Elrahim, Ramy Abdallah Abd
    Shown, Ahmed
    Abdellah, Mahmoud
    Abualsaud, Reem
    Helal, Mohamed Ahmed
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (07): : 691 - 699
  • [7] Power brushing and chemical denture cleansers induced color changes of pre-polymerized CAD/CAM denture acrylic resins
    Alfouzan, Afnan F.
    AlNouwaisar, Alhanouf N.
    AlAzzam, Njood F.
    Al-Otaibi, Hanan N.
    Labban, Nawaf
    Alswaidan, Mashaal H.
    Al Taweel, Sara M.
    Alshehri, Huda A.
    MATERIALS RESEARCH EXPRESS, 2021, 8 (08)
  • [8] Effect of thermal cycling on the flexural strength of 3-D printed, CAD/CAM milled and heat-polymerized denture base materials
    Tuğba Temizci
    Hatice Nalan Bozoğulları
    BMC Oral Health, 24
  • [9] Effect of thermal cycling on the flexural strength of 3-D printed, CAD/CAM milled and heat-polymerized denture base materials
    Temizci, Tugba
    Bozogullari, Hatice Nalan
    BMC ORAL HEALTH, 2024, 24 (01)
  • [10] Efficacy of Denture Cleansers on Microbial Adherence and Surface Topography of Conventional and CAD/CAM-Processed Denture Base Resins
    Alfouzan, Afnan F.
    Tuwaym, Malath
    Aldaghri, Ebtihal N.
    Alojaymi, Tagreed
    Alotiabi, Hadeel Minife
    Taweel, Sara M. Al
    Al-Otaibi, Hanan N.
    Ali, Rizwan
    Alshehri, Huda
    Labban, Nawaf
    POLYMERS, 2023, 15 (02)