A novel unilateral extrapedicular approach applied to percutaneous vertebral augmentation to treat thoracic and lumbar Osteoporotic Vertebral Compression Fracture: a retrospective study

被引:0
作者
Yang, Bo [1 ]
Wang, Shenghai [1 ]
机构
[1] Hanzhong Cent Hosp, Dept Spinal Surg Ward 1, 22Kangfu Rd, Hanzhong 723000, Shaanxi, Peoples R China
关键词
Osteoporotic vertebral compression fracture; Percutaneous vertebral augmentation; Extrapedicular; Cement distribution; BONE-CEMENT DISTRIBUTION; QUALITY-OF-LIFE; CLINICAL-EFFICACY; KYPHOPLASTY; VERTEBROPLASTY;
D O I
10.1186/s12891-024-07980-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
ObjectiveTo design and apply a novel puncture method, named P TO P technique, and to evaluate its efficacy and safety.MethodThe data of patients treated with PVA in medical institution from January 2020 to December 2022 were reviewed and analyzed. The degree of pain relief and recovery from daily activities were evaluated using VAS and LAS scores, and radiological parameters were evaluated using local kyphosis angle and excellent cement distribution. Complications such as cement leakage and recurrent vertebral fractures were also recorded.Results157 patients with thoracolumbar OVCF were successfully treated with novel puncture techniques. All postoperative clinical and radiological parameters significantly decreased in all patients, except for an increase in local kyphosis angle at the last follow-up compared to postoperative. All other above indicators remained statistically significant at the last follow-up compared to postoperative improvement. Except for 2 patients with poor cement distribution, the remaining 155 patients successfully achieved satisfactory results in unilateral puncture and bilateral cement distribution, achieving an excellent rate of 98.73%. In addition, 18 cases (11.46%) of cement leakage occurred during the operation, fortunately none of them were uncomfortable. During the postoperative follow-up period, 4 cases (2.55%) of recurrent fractures occurred. No other serious complications such as neurologic or named vascular injuries occurred.ConclusionThe application of P TO P technology in thoracolumbar OVCF patients is safe and effective. It can not only reduce pain and quickly recover daily activities, but also achieve the perfect effect of unilateral puncture and bilateral cement filling.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Percutaneous vertebroplasty for osteoporotic vertebral compression fracture (Review)
    Buchbinder, Rachelle
    Johnston, Renea V.
    Rischin, Kobi J.
    Homik, Joanne
    Jones, C. Allyson
    Golmohammadi, Kamran
    Kallmes, David F.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2018, (11):
  • [32] Comparison of Unilateral and Bilateral Percutaneous Kyphoplasty for Osteoporotic Vertebral Compression Fractures
    Qiao, Yu
    Wang, Xin
    Liu, Yi
    Hu, Jun
    Yuan, Fa-Hu
    Zhao, Zhi-Gang
    JOURNAL OF PAIN RESEARCH, 2023, 16 : 1813 - 1823
  • [33] Exploration of percutaneous vertebroplasty in the treatment of osteoporotic vertebral compression fracture as day surgery: a retrospective study
    Boyuan Nie
    Qingling Wang
    Beilei Li
    Ning Ou
    Zhaohui Yang
    European Spine Journal, 2021, 30 : 2718 - 2725
  • [34] Percutaneous Kyphoplasty in Patients with Severe Osteoporotic Vertebral Compression Fracture with and without Intravertebral Cleft: A Retrospective Comparative Study
    Liu, Hao
    Zhou, Quan
    Shao, Xiaofeng
    Zhang, Junxin
    Deng, Lei
    Liu, Tao
    Yang, Huilin
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2022, 15 : 6199 - 6209
  • [35] Thoracolumbar Osteoporotic Vertebral Compression Fracture Treatment by Unilateral Percutaneous Vertebroplasty Using Curved Diffusion Needle
    Hu, Haigang
    Lin, Xu
    Tan, Lun
    INDIAN JOURNAL OF ORTHOPAEDICS, 2023, 57 (06) : 899 - 906
  • [36] Percutaneous Balloon Kyphoplasty Vertebral Augmentation for Compression Fracture Due to Vertebral Metastasis: A 12-Month Retrospective Clinical Study in 72 Patients
    Kircelli, Atilla
    Coven, Ilker
    MEDICAL SCIENCE MONITOR, 2018, 24 : 2142 - 2148
  • [37] What is the importance of “halo” phenomenon around bone cement following vertebral augmentation for osteoporotic compression fracture?
    K. H. Kim
    S. U. Kuh
    J. Y. Park
    K. S. Kim
    D. K. Chin
    Y. E. Cho
    Osteoporosis International, 2012, 23 : 2559 - 2565
  • [38] What is the importance of "halo" phenomenon around bone cement following vertebral augmentation for osteoporotic compression fracture?
    Kim, K. H.
    Kuh, S. U.
    Park, J. Y.
    Kim, K. S.
    Chin, D. K.
    Cho, Y. E.
    OSTEOPOROSIS INTERNATIONAL, 2012, 23 (10) : 2559 - 2565
  • [39] Predictive Factors for Adjacent Vertebral Fractures After Percutaneous Kyphoplasty in Patients With Osteoporotic Vertebral Compression Fracture
    Wu Tao
    Wang Biao
    Chen Xingmei
    Qin Hu
    Sun Jinpeng
    Gu Yue
    Liu Jun
    PAIN PHYSICIAN, 2022, 25 (05) : E725 - E732
  • [40] Unilateral Percutaneous Kyphoplasty Using a Novel Guide Device for Thoracolumbar Osteoporotic Vertebral Fracture
    Wang, Hongwei
    Yu, Hailong
    Zhu, Yunpeng
    Gu, Hongwen
    Zheng, Bin
    Zhao, Yuanhang
    Han, Wenfeng
    Xiang, Liangbi
    ORTHOPAEDIC SURGERY, 2023, 15 (04) : 993 - 1001