Establishment of baseline size-specific dose estimate (SSDE) for paediatric head computed tomography (CT) examinations

被引:0
|
作者
Sulemana, Hamza [1 ]
Mumuni, Abdul Nashirudeen [1 ]
Abubakari, Izre-deen Osman Mohammed [1 ]
机构
[1] Univ Dev Studies, Sch Allied Hlth Sci, Dept Med Imaging Technol, Box TL 1883, Tamale, Northern Region, Ghana
来源
EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE | 2024年 / 55卷 / 01期
关键词
Paediatric head; Radiation dose; Volume computed tomography dose index (CTDIvol); Size-specific dose estimates (SSDE); Water-equivalent diameter (D-W); WATER-EQUIVALENT DIAMETER; PATIENT SIZE; INDEX; AGE;
D O I
10.1186/s43055-024-01396-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background In recent times, size-specific dose estimate (SSDE) has been the ideal metric for accurate estimation of individual patient doses in computed tomography (CT) examinations. The objective of this study was to estimate patient radiation doses based on SSDE and the water-equivalent diameter (D-W) as an effect tool for dose optimization in paediatric head CT at two facilities in Tamale Metropolis, in the northern region of Ghana. This is a preliminary retrospective study conducted on 57 paediatric patients (comprising 32 males and 25 females), aged newborns to 16 years old, who underwent head CT examinations. Patient head sizes were determined in terms D-W, which was calculated by manual contouring the circumference of the CT images excluding the background to measure the region of interest (ROI) using the mid-slice axial CT images. SSDE was calculated as the product of CTDIvol and the size-specific conversion coefficients (CTDIvol, 16 to SSDE) obtained from the American Association of Physicists in Medicine (AAPM) Report 293. Results At facility 'A', the median SSDE values for patients, aged 3 months to 1 year, 1 to 6 years, and older than 6 years were 46.1 mGy, 39.6 mGy, and 48.2 mGy, respectively. The corresponding CTDIvol values were 42.3 mGy, 39.1 mGy, and 51.7 mGy. Facility 'B' reported median SSDE values of 36.0, 39.2, and 43.8 mGy, with corresponding CTDIvol values of 28.7, 39.8, and 46.9 mGy for the same age categories. For all age groups, the two facilities showed significant differences in SSDE values (44.72 mGy vs. 39.77 mGy, p = 0.009) and CTDIvol values (45.72 mGy vs. 40.60 mGy, p = 0.03). Some of the age group doses were up to 25.3% in CTDIvol and 25.8% in SSDE higher than those found in published data. Conclusions The SSDEs estimated showed significant variations between the two facilities, indicating a possible variability of scan protocols for paediatric head CT examinations. The SSDEs obtained in this study could be useful for optimization of paediatric routine head CT examinations.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Comparison of central, peripheral, and weighted size-specific dose in CT
    Choirul, Anam
    Adhianto, Dwi
    Sutanto, Heri
    Adi, Kusworo
    Ali, Mohd Hanafi
    Rae, William Ian Duncombe
    Fujibuchi, Toshioh
    Dougherty, Geoff
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2020, 28 (04) : 695 - 708
  • [42] Size-specific dose estimations for pediatric chest, abdomen/pelvis and head CT scans with the use of GATE
    Kostou, Theodora
    Papadimitroulas, Panagiotis
    Papaconstadopoulos, Pavlos
    Devic, Slobodan
    Seuntjens, Jan
    Kagadis, George C.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 65 : 181 - 190
  • [43] Body physical parameters instead of water equivalent diameter to calculate size-specific dose estimate in adult chest CT
    Hu, Xiaoyan
    Gou, Jie
    Yang, Fan
    Guo, Dajing
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [44] Correlation of size-dependent conversion factor and body-mass-index using size-specific dose estimates formalism in CT examinations
    Alikhani, Babak
    Getzin, Tobias
    Kaireit, Till Frederik
    Ringe, Kristina Imeen
    Jamali, Leila
    Wacker, Frank
    Werncke, Thomas
    Raatschen, Hans-Juergen
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 100 : 130 - 134
  • [45] Estimating size specific dose estimate from computed tomography radiograph localizer with radiation risk assessment
    Burton, Christiane Sarah
    Al-Ward, Shahad
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (06):
  • [46] Correlations Between Body Weight and Size- Specific Dose Estimate on Thoracic Computed Tomography Examination
    Wati, A. L.
    Anam, C.
    Nitasari, A.
    Syarifudin
    Dougherty, G.
    ATOM INDONESIA, 2022, 48 (01) : 61 - 65
  • [47] A new approach to dose reference levels in pediatric CT: Age and size-specific dose estimation
    Rawashdeh, Mohammad
    Saade, Charbel
    Mousa, Dana S. Al
    Abdelrahman, Mostafa
    Kumar, Praveen
    McEntee, Mark
    RADIATION PHYSICS AND CHEMISTRY, 2023, 205
  • [48] Size-specific Dose Estimation for CT: How Should It Be Used and What Does It Mean?
    Brink, James A.
    Morin, Richard L.
    RADIOLOGY, 2012, 265 (03) : 666 - 668
  • [49] An improved method for automated calculation of the water-equivalent diameter for estimating size-specific dose in CT
    Anam, Choirul
    Mahdani, Fahmi Rosydiansyah
    Dewi, Winda Kusuma
    Sutanto, Heri
    Triadyaksa, Pandji
    Haryanto, Freddy
    Dougherty, Geoff
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (09): : 313 - 323
  • [50] CAN THE SIZE-SPECIFIC DOSE ESTIMATE BE DERIVED FROM THE BODY MASS INDEX? A FEASIBILITY STUDY
    Steiniger, Beatrice
    Klippel, Chris
    Teichgraeber, Ulf
    Reichenbach, Juergen R.
    Fiebich, Martin
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (06) : 325 - 333