Establishment of baseline size-specific dose estimate (SSDE) for paediatric head computed tomography (CT) examinations

被引:0
作者
Sulemana, Hamza [1 ]
Mumuni, Abdul Nashirudeen [1 ]
Abubakari, Izre-deen Osman Mohammed [1 ]
机构
[1] Univ Dev Studies, Sch Allied Hlth Sci, Dept Med Imaging Technol, Box TL 1883, Tamale, Northern Region, Ghana
关键词
Paediatric head; Radiation dose; Volume computed tomography dose index (CTDIvol); Size-specific dose estimates (SSDE); Water-equivalent diameter (D-W); WATER-EQUIVALENT DIAMETER; PATIENT SIZE; INDEX; AGE;
D O I
10.1186/s43055-024-01396-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background In recent times, size-specific dose estimate (SSDE) has been the ideal metric for accurate estimation of individual patient doses in computed tomography (CT) examinations. The objective of this study was to estimate patient radiation doses based on SSDE and the water-equivalent diameter (D-W) as an effect tool for dose optimization in paediatric head CT at two facilities in Tamale Metropolis, in the northern region of Ghana. This is a preliminary retrospective study conducted on 57 paediatric patients (comprising 32 males and 25 females), aged newborns to 16 years old, who underwent head CT examinations. Patient head sizes were determined in terms D-W, which was calculated by manual contouring the circumference of the CT images excluding the background to measure the region of interest (ROI) using the mid-slice axial CT images. SSDE was calculated as the product of CTDIvol and the size-specific conversion coefficients (CTDIvol, 16 to SSDE) obtained from the American Association of Physicists in Medicine (AAPM) Report 293. Results At facility 'A', the median SSDE values for patients, aged 3 months to 1 year, 1 to 6 years, and older than 6 years were 46.1 mGy, 39.6 mGy, and 48.2 mGy, respectively. The corresponding CTDIvol values were 42.3 mGy, 39.1 mGy, and 51.7 mGy. Facility 'B' reported median SSDE values of 36.0, 39.2, and 43.8 mGy, with corresponding CTDIvol values of 28.7, 39.8, and 46.9 mGy for the same age categories. For all age groups, the two facilities showed significant differences in SSDE values (44.72 mGy vs. 39.77 mGy, p = 0.009) and CTDIvol values (45.72 mGy vs. 40.60 mGy, p = 0.03). Some of the age group doses were up to 25.3% in CTDIvol and 25.8% in SSDE higher than those found in published data. Conclusions The SSDEs estimated showed significant variations between the two facilities, indicating a possible variability of scan protocols for paediatric head CT examinations. The SSDEs obtained in this study could be useful for optimization of paediatric routine head CT examinations.
引用
收藏
页数:9
相关论文
共 28 条
[1]  
American Association of Physicists in Medicine (AAPM), 2015, Pediatric routine head CT protocols version1.1
[2]   Multi-slice CT examinations of adult patients at Sudanese hospitals: radiation exposure based on size-specific dose estimates (SSDE) [J].
Bashier, Einas H. ;
Suliman, I. I. .
RADIOLOGIA MEDICA, 2018, 123 (06) :424-431
[3]  
Boone J, 2011, AAPM report No. 204: size-specific dose estimates (SSDE) in pediatric and adult body CT examinations
[4]  
Boone JM, 2019, AAPM Report No.293
[5]   Reply to "Comment on the 'Report of AAPM TG 204: Size-specific dose estimates (SSDE) in pediatric and adult body CT examinations'" [AAPM Report 204, 2011] [J].
Boone, John M. .
MEDICAL PHYSICS, 2012, 39 (07) :4615-4616
[6]   Institutional computed tomography diagnostic reference levels based on water-equivalent diameter and size-specific dose estimates [J].
Boos, Johannes ;
Thomas, Christoph ;
Appel, Elisabeth ;
Klosterkemper, Yan ;
Schleich, Christoph ;
Aissa, Joel ;
Bethge, Oliver Th ;
Antoch, Gerald ;
Kroepil, Patric .
JOURNAL OF RADIOLOGICAL PROTECTION, 2018, 38 (02) :536-548
[7]   Automated Pediatric Abdominal Effective Diameter Measurements Versus Age-Predicted Body Size for Normalization of CT Dose [J].
Cheng, Phillip M. ;
Vachon, Linda A. ;
Duddalwar, Vinay A. .
JOURNAL OF DIGITAL IMAGING, 2013, 26 (06) :1151-1155
[8]   PATIENTS DOSE ESTIMATION IN CT EXAMINATIONS USING SIZE SPECIFIC DOSE ESTIMATES [J].
Choudhary, Neha ;
Rana, Bhupendra Singh ;
Shukla, Arvind ;
Oinam, Arun Singh ;
Singh, Narinder Paul ;
Kumar, Sanjeev .
RADIATION PROTECTION DOSIMETRY, 2019, 184 (02) :256-262
[9]   Risk of hematological malignancies from CT radiation exposure in children, adolescents and young adults [J].
de Basea, Magda Bosch ;
Thierry-Chef, Isabelle ;
Harbron, Richard ;
Hauptmann, Michael ;
Byrnes, Graham ;
Bernier, Maria-Odile ;
Le Cornet, Lucian ;
Dabin, Jeremie ;
Ferro, Gilles ;
Istad, Tore S. ;
Jahnen, Andreas ;
Lee, Choonsik ;
Maccia, Carlo ;
Malchair, Francoise ;
Olerud, Hilde ;
Simon, Steven L. ;
Figuerola, Jordi ;
Peiro, Anna ;
Engels, Hilde ;
Johansen, Christoffer ;
Blettner, Maria ;
Kaijser, Magnus ;
Kjaerheim, Kristina ;
Berrington de Gonzalez, Amy ;
Journy, Neige ;
Meulepas, Johanna M. ;
Moissonnier, Monika ;
Nordenskjold, Arvid ;
Pokora, Roman ;
Ronckers, Cecile ;
Schuz, Joachim ;
Kesminiene, Ausrele ;
Cardis, Elisabeth .
NATURE MEDICINE, 2023, 29 (12) :3111-3119
[10]  
European Union, 2018, European Guidelines on Diagnostic Reference Levels for Paediatric Imaging