Quality analysis of photometers using vertical window illuminance measurements

被引:0
作者
Tabaka, Przemyslaw [1 ]
Sciezor, Tomasz [2 ]
机构
[1] Lodz Univ Technol, Inst Elect Power Engn, Lodz, Poland
[2] Cracow Univ Technol, Fac Environm Engn & Energy, Krakow, Poland
来源
SCIENTIFIC REPORTS | 2024年 / 14卷 / 01期
关键词
Outdoor lighting; Obtrusive light; Light trespass; Vertical illumination; Lux meter; Apartment building; LIGHT POLLUTION;
D O I
10.1038/s41598-024-82123-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In urban areas, one of the main forms of light pollution is the intrusion of light through windows into residential buildings. This phenomenon can harm human health, so standards have been introduced to define limits for vertical illuminance. This study aims to assess the levels of outdoor lighting on the windows of residential buildings in Poland in terms of compliance with standards for protection against intrusive light, as well as to compare the results obtained using various commercially available photometers. The paper presents the results of field measurements of vertical illuminance on the window surfaces of 17 residential buildings in several cities in Poland. The measurements were made with 22 photometers representing different metrological levels. The measuring instruments selected for the study are a sample of commercially available photometers. Despite the same lighting conditions on the surface of the individual windows, discrepancies can be seen in the measured illuminance values of the different photometers. The vertical illuminance measurements were subjected to statistical analysis. It was found that of the 22 photometers, only a few were suitable for assessing obtrusive light from outdoor lighting installations. It has also been noted that on window surfaces, in buildings located on a busy street in the city centre, the illuminance can reach up to 100 lx, many times exceeding the permissible values of 1, 2, 5, 10 and 25 lx.
引用
收藏
页数:12
相关论文
共 37 条
[1]  
[Anonymous], 2014, Directive /32/EU of the European Parlament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of measuring instruments
[2]  
[Anonymous], 2017, CIE 150. 2017 Guide on the Limitation of the Effects of Obtrusive Light from Outdoor Lighting Installations, DOI [10.25039/TR.150.2017, DOI 10.25039/TR.150.2017]
[3]  
[Anonymous], 2022, Obwieszczenie Ministra Zdrowia z dnia 27 lutego 2018 r. w sprawie ogloszenia jednolitego tekstu rozporzadzenia Ministra Zdrowia w sprawie zakresu badan niezbednych do ustalenia wlasciwosci leczniczych naturalnych surowcow leczniczych i wlasciwosci leczniczych klimatu
[4]   Association between outdoor artificial light at night and low birth weight in California [J].
Boakye, Kwadwo ;
Iyanda, Ayodeji ;
Asante, Emmanuel ;
Oppong, Joseph .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL HEALTH RESEARCH, 2024,
[5]  
Bochen I., 2019, Sustainability, V11, P3446, DOI [10.3390/su11133446, DOI 10.3390/SU11133446]
[6]  
Boczkowski A., 2014, Elektro Info, V9, P66
[7]  
Boyce P. R., 2000, International Journal of Lighting Research and Technology, V32, P79, DOI 10.1177/096032710003200205
[8]   Outdoor artificial light at night and human health: A review of epidemiological studies [J].
Bozejko, Mateusz ;
Tarski, Ignacy ;
Malodobra-Mazur, Malgorzata .
ENVIRONMENTAL RESEARCH, 2023, 218
[9]   The effects of dimmable road lighting: A comparison of measured and perceived visibility [J].
Chenani, Sanaz Bozorg ;
Maksimainen, Mikko ;
Tetri, Eino ;
Kosonen, Iisakki ;
Luttinen, Tapio .
TRANSPORTATION RESEARCH PART F-TRAFFIC PSYCHOLOGY AND BEHAVIOUR, 2016, 43 :141-156
[10]  
Dubnicka R., 2019, CIE, Vx046, DOI [10.25039/x46.2019.PP22, DOI 10.25039/X46.2019.PP22]