Semiconductors' efficiency: lithium dead layer detection of high-purity Germanium detectors

被引:0
作者
Nabil, Islam M. [1 ]
El-Kourghly, K. M. [2 ]
Mohamed, Y. [1 ]
Ebaid, Yasser Y. [1 ]
El-Gammal, W. [2 ]
机构
[1] Fayoum Univ, Fac Sci, Phys Dept, Al Fayyum, Egypt
[2] Egyptian Atom Energy Author EAEA, Nucl Safeguards & Phys Protect Dept, Cairo, Egypt
关键词
Peak efficiency; Relative method; Absolute method; Monte Carlo simulation; HPGe; Gamma spectroscopy; PEAK EFFICIENCY; QUANTIFICATION;
D O I
10.1007/s41605-024-00505-5
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This study presents a mathematical model for the peak efficiency of a coaxial high-purity germanium detector using the Monte Carlo code (MCNP), based on data provided by the manufacturer. Consequently, the detector's model is optimized using a trial-and-error methodology, either by increasing/decreasing the dead layer thickness, aligning the peak efficiency results with experimental measurements. Results indicate that, over 15 years of continuous operation, the dead layer is approximately twice as thick as initially quoted by the manufacturer. Therefore, the dead layer results would confirm that it is crucial to regularly optimize the dead layer over time, as the operator needs to address potential occasional changes. The results indicate that the optimized MC model is suitable for calculating the activity of point/volumetric radioactive sources, with relative errors of 4.40 and 3.23%, respectively. Moreover, this work discusses the different factors that affect the accuracy of the absolute efficiency calibration of gamma spectrometers.
引用
收藏
页码:171 / 183
页数:13
相关论文
共 34 条
[1]   Investigation of shape effects and dead layer thicknesses of a coaxial HPGe crystal on detector efficiency by using PHITS Monte Carlo simulation [J].
Bolukdemir, M. H. ;
Uyar, E. ;
Aksoy, G. ;
Unlu, H. ;
Dikmen, H. ;
Ozgur, M. .
RADIATION PHYSICS AND CHEMISTRY, 2021, 189
[2]   A detailed investigation of HPGe detector response for improved Monte Carlo efficiency calculations [J].
Boson, Jonas ;
Agren, Goeran ;
Johansson, Lennart .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 587 (2-3) :304-314
[3]  
Briesmeister J.F, 2000, LA13709M LANL
[4]   Detection efficiency of NaI(Tl) detector based on the fabricated calibration of HPGe detector [J].
El-Gamal, Hany ;
Negm, Hani ;
Hasabelnaby, Mohamed .
JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2019, 12 (01) :360-366
[5]   A hybrid analytical-numerical method for full energy peak efficiency calibration of a NaI detector [J].
El-Gammal, W. ;
El-Kourghly, K. M. ;
El-Tahawy, M. S. ;
Abdelati, M. ;
Abdelsalam, A. ;
Osman, W. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 976
[6]   Application of a hybrid method for efficiency calibration of a NaI detector [J].
El-Kourghly, K. M. ;
El-Gammal, W. ;
El-Tahawy, M. S. ;
Abdelati, M. ;
Abdelsalam, A. ;
Osman, W. .
APPLIED RADIATION AND ISOTOPES, 2021, 171
[7]   INITIAL MCNP6 RELEASE OVERVIEW [J].
Goorley, T. ;
James, M. ;
Booth, T. ;
Brown, F. ;
Bull, J. ;
Cox, L. J. ;
Durkee, J. ;
Elson, J. ;
Fensin, M. ;
Forster, R. A. ;
Hendricks, J. ;
Hughes, H. G. ;
Johns, R. ;
Kiedrowski, B. ;
Martz, R. ;
Mashnik, S. ;
McKinney, G. ;
Pelowitz, D. ;
Prael, R. ;
Sweezy, J. ;
Waters, L. ;
Wilcox, T. ;
Zukaitis, T. .
NUCLEAR TECHNOLOGY, 2012, 180 (03) :298-315
[8]  
Gurau D, 2023, ROM J PHYS, V68
[9]  
Heath R. L., 1958, Tech. Rep. IDO-16370
[10]  
Heath R.L, 1964, Tech. Rep. IDO-16880-1