Highly sensitive electrochemical determination of agomelatine in biological samples based on Cu nanoparticles/Schiff base network1 modified glassy carbon electrode: DFT and experimental studies

被引:3
作者
Ajdari, Beheshteh [1 ]
Madrakian, Tayyebeh [1 ]
Sarvestani, Mohammad Reza Jalali [1 ]
Afkhami, Abbas [1 ]
机构
[1] Bu Ali Sina Univ, Fac Chem & Petr Sci, Dept Analyt Chem, Hamadan 6517838695, Iran
关键词
Agomelatine; Square wave voltammetry; Electrochemical sensor; Density functional theory; Box-Behnken design; VOLTAMMETRIC DETERMINATION; ENERGY-STORAGE; HUMAN PLASMA; OPTIMIZATION; ADSORPTION; MICROEXTRACTION; QUANTIFICATION; NANOCOMPOSITE; SURFACTANTS; MELATONIN;
D O I
10.1016/j.talanta.2024.127174
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a nanocomposite of copper nanoparticles incorporated into a covalent organic framework (Cu@SNW1) was synthesized and characterized by various approaches such as scanning electron microscopy, cyclic voltammetry, X-ray diffraction, electrochemical impedance spectroscopy, and energy dispersive X-ray spectroscopy. The interaction between the nanocomposite and agomelatine (AGM) was investigated through density functional theory computations. The results indicated that the nanocomposite displays electrocatalytic properties towards AGM and their interactions are both experimentally and thermodynamically viable. The synthesized nanocomposite was employed as an electrocatalytic modifier for the highly selective and sensitive square wave anodic stripping voltammetric detection of AGM. Experimental parameters including; pH, deposition time, modifier concentration, and deposition potential were fine-tuned using the Box-Behnken experimental design strategy. Under the optimal conditions, a linear correlation was established between the anodic peak current of AGM and its concentration across two linear ranges, 0.007-1.00 mu mol L- 1 and 1.00-6.50 mu mol L- 1 . The method demonstrated a limit of detection of 0.002 mu mol L- 1 under the optimized parameters. Furthermore, the proposed method exhibited high sensitivity and selectivity in determining AGM in urine, serum, and saliva samples.
引用
收藏
页数:11
相关论文
共 50 条
[21]   Highly Sensitive and Selective Electrochemical Determination of 4-Aminophenol Based on Flower-Like Ag-Au Nanocomposites Modified Glassy Carbon Electrode [J].
Zhang, Hongding ;
Xing, Zhenhua ;
Pan, Miaomiao ;
Wang, Hai-Bo ;
Liu, Yan-Ming .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (12)
[22]   Highly sensitive square wave voltammetric method for determination of brucine in artificial urine samples based on choline chloride modified glassy carbon electrode [J].
Biya, Semira ;
Negash, Negussie ;
Hailu, Tesfu ;
Tesfaye, Gizaw ;
Yaya, Estifanose Ele .
HELIYON, 2023, 9 (03)
[23]   Sensitive electrochemical sensor based on gold nanoparticles assembled ferrocene-functionalised graphene oxide modified glassy carbon electrode for simultaneous determination of dopamine and acetaminophen [J].
Changsan, Nirankan ;
Chairam, Sanoe ;
Jarujamrus, Purim ;
Amatatongchai, Maliwan .
ADVANCES IN NATURAL SCIENCES-NANOSCIENCE AND NANOTECHNOLOGY, 2022, 13 (01)
[24]   A Novel Sensitive Electrochemical Sensor Based on Nickel Chloride Solution Modified Glassy Carbon Electrode for Curcumin Determination [J].
Zokhtareh, Rosan ;
Rahimnejad, Mostafa .
ELECTROANALYSIS, 2018, 30 (05) :921-927
[25]   Development of novel electrochemical sensor on the base of molecular imprinted polymer decorated on SiC nanoparticles modified glassy carbon electrode for selective determination of loratadine [J].
Roushani, Mahmoud ;
Nezhadali, Azizollah ;
Jalilian, Zeynab ;
Azadbakht, Azadeh .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 71 :1106-1114
[26]   Preparation of a glassy carbon electrode modified with saffron conjugated silver nanoparticles for the sensitive and selective electroanalytical determination of amoxicillin in urine samples [J].
Sarakatsanou, Christina ;
Karastogianni, Sophia ;
Girousi, Stella .
ANALYTICAL METHODS, 2023, 15 (35) :4572-4581
[27]   Enhanced Electrochemical Determination of Catechol and Hydroquinone Based on Pd Nanoparticles/Poly(Taurine) Modified Glassy Carbon Electrode [J].
Kocak, Cagri Ceylan ;
Kocak, Suleyman .
ELECTROANALYSIS, 2020, 32 (02) :358-366
[28]   Highly sensitive simultaneous electrochemical determination of reduced and oxidized glutathione in urine samples using antimony trioxide modified carbon paste electrode [J].
Stojanovic, Zorica S. ;
Durovic, Ana D. ;
Ashrafi, Amir M. ;
Koudelkova, Zuzana ;
Zitka, Ondrej ;
Richtera, Lukas .
SENSORS AND ACTUATORS B-CHEMICAL, 2020, 318
[29]   Electrocatalytic reduction of nitrite and bromate and their highly sensitive determination on carbon paste electrode modified with new copper Schiff base complex [J].
Ourari, Ali ;
Ketfi, Bouzid ;
Malha, Seif Islam Rabie ;
Amine, Aziz .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 797 :31-36
[30]   Highly sensitive electrochemical sensor for tulobuterol detection based on facile graphene/Au nanowires modified glassy carbon electrode [J].
Huang, Huayu ;
Nie, Rong ;
Song, Yanyan ;
Ji, Yongsheng ;
Guo, Rui ;
Liu, Zhihua .
SENSORS AND ACTUATORS B-CHEMICAL, 2016, 230 :422-426