High-Voltage Power Supply for X-ray Control of the Structure of Materials

被引:0
|
作者
Dmitriev, A. S. [1 ]
Kuleshov, A. D. [1 ]
Potrakhov, N. N. [1 ]
Potrakhov, Yu. N. [1 ]
Guk, K. K. [1 ]
机构
[1] Petersburg Electrotech Univ LETI, St Petersburg 197022, Russia
关键词
stabilized high-voltage power supply; X-ray tube;
D O I
10.1134/S0020168524700699
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A high-voltage power supply, along with an X-ray tube, is one of the main components of X-ray machines widely used in studying the structure of materials, estimating the internal structure of components and mechanisms, and nondestructive testing of technological processes. In monoblock devices, an X-ray tube and power supply are located in a common housing, while in cable-type setups, an X-ray emitter with the tube and a power supply are connected by a high-voltage cable. In this study, the results of creation of a stabilized high-voltage power supply for X-ray tubes as a part of a cable-type machine are reported. The electric circuits and design of the power supply based on a full-bridge voltage inverter built on power bipolar transistors are developed. The output voltage and power of the source are adjusted through the pulse width modulation of the rectified mains voltage applied to the primary winding of a high-voltage transformer. The use of a solid-state compound with increased thermal conductivity has made it possible to limit the design to forced air cooling of the source and place it within the Rack Mount standard dimensions (4U form factor). The experience of the power supply operation at a large industrial enterprise has shown that its electrical and dimensional parameters provide the possibility of successful use in X-ray machines for structure control of materials.
引用
收藏
页码:444 / 449
页数:6
相关论文
共 50 条
  • [21] A Low Ripple Voltage Multiplier for X-ray Power Supply
    Iqbal, Shahid
    Besar, Rosli
    Venkataseshiah, C.
    2008 IEEE 2ND INTERNATIONAL POWER AND ENERGY CONFERENCE: PECON, VOLS 1-3, 2008, : 1451 - 1455
  • [22] QUALITY CONTROL AND ENVIRONMENTAL IMPACT OF HIGH-VOLTAGE INSULATING OILS FOR X-RAY GENERATORS
    Ginovska, M.
    Spasevska, H.
    Najdenkoski, K.
    JOURNAL OF ENVIRONMENTAL PROTECTION AND ECOLOGY, 2009, 10 (02): : 380 - 385
  • [23] Novel digital control topology of a high power resonant DC-DC converter for X-ray high-voltage applications
    Takano, H
    Hatakeyama, T
    Gamage, L
    Sun, JM
    Nakaoka, M
    PROCEEDINGS OF THE POWER CONVERSION CONFERENCE - NAGAOKA 1997, VOLS I AND II, 1997, : 1013 - 1018
  • [24] HIGH-VOLTAGE TRANSISTOR CONVERTER FOR PULSED X-RAY SOURCES
    KRASILNIKOV, SB
    KRISTALINSKII, AL
    LOZOVOI, LN
    MARKOV, SN
    SINDALOVSKII, EI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1986, 29 (02) : 421 - 422
  • [25] CONTROLLED HIGH-VOLTAGE CONVERTER FOR PULSED X-RAY SOURCES
    LOZOVOI, LN
    SINDALOVSKII, EI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1989, 32 (02) : 470 - 473
  • [26] Effect of X-ray High-voltage Variations on the Conversion Coefficients
    Behnke, B.
    Hupe, O.
    Behrens, R.
    RADIATION PROTECTION DOSIMETRY, 2017, 175 (02) : 163 - 170
  • [27] Modelling of electric fields in high-voltage x-ray devices
    Ma, Nancy
    Miller, Eric J.
    Jones, Vincent F.
    Kozaczek, Kris J.
    JOURNAL OF ELECTROSTATICS, 2019, 99 : 59 - 65
  • [28] X-RAY EMISSION FROM HIGH-VOLTAGE HYDROGEN THYRATRONS
    SCHNEIDER, S
    REICH, B
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1955, 43 (06): : 711 - 715
  • [29] A water-cooled high-voltage x-ray tube
    Coolidge, W. D.
    Moore, C. N.
    AMERICAN JOURNAL OF ROENTGENOLOGY AND RADIUM THERAPY, 1923, 10 : 884 - 890