Thirteen serum biochemical indexes and five whole blood coagulation indices in a point-of-care testing analyzer: ideal protocol for evaluating pulmonary and critical care medicine

被引:0
|
作者
Liu, Mingtao [1 ]
Liu, Li [1 ]
Chen, Jiaxi [2 ]
Huang, Zhifeng [1 ]
Zhu, Huiqing [1 ]
Lin, Shengxuan [3 ]
Qi, Weitian [4 ]
Cheng, Zhangkai J. [1 ]
Li, Ning [1 ]
Sun, Baoqing [1 ]
机构
[1] Guangzhou Med Univ, Affiliated Hosp 1, Natl Ctr Resp Med, Guangzhou Inst Resp Hlth,State Key Lab Resp Dis,Na, Guangzhou 510140, Peoples R China
[2] Guangzhou Med Univ, KingMed Sch Lab Med, Guangzhou 511495, Peoples R China
[3] Guangdong Med Univ, Coll Med Technol, Dongguan 523121, Peoples R China
[4] Southern Med Univ, Clin Med Sch 2, Guangzhou 510515, Peoples R China
来源
JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE B | 2025年 / 26卷 / 02期
基金
中国国家自然科学基金;
关键词
Thirteen serum biochemical indexes; Five whole blood coagulation indices; Point-of-care testing (POCT); Pulmonary and critical care medicine; Diagnostic protocol; COVID-19; PROTEIN; DISEASE; POCT;
D O I
10.1631/jzus.B2300433
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The accurate and timely detection of biochemical coagulation indicators is pivotal in pulmonary and critical care medicine. Despite their reliability, traditional laboratories often lag in terms of rapid diagnosis. Point-of-care testing (POCT) has emerged as a promising alternative, which is awaiting rigorous validation. We assessed 226 samples from patients at the First Affiliated Hospital of Guangzhou Medical University using a Beckman Coulter AU5821 and a PUSHKANG POCT Biochemistry Analyzer MS100. Furthermore, 350 samples were evaluated with a Stago coagulation analyzer STAR MAX and a PUSHKANG POCT Coagulation Analyzer MC100. Metrics included thirteen biochemical indexes, such as albumin, and five coagulation indices, such as prothrombin time. Comparisons were drawn against the PUSHKANG POCT analyzer. Bland-Altman plots (MS100: 0.8206-0.9995; MC100: 0.8318-0.9911) evinced significant consistency between methodologies. Spearman correlation pinpointed a potent linear association between conventional devices and the PUSHKANG POCT analyzer, further underscored by a robust correlation coefficient (MS100: 0.713-0.949; MC100: 0.593-0.950). The PUSHKANG POCT was validated as a dependable tool for serum and whole blood biochemical and coagulation diagnostics. This emphasizes its prospective clinical efficacy, offering clinicians a swift diagnostic tool and heralding a new era of enhanced patient care outcomes.