Image Quality and Tumor Shape Correction in Sparse Projection Cone-Beam CT Using Conditional Generative Adversarial Networks

被引:0
|
作者
Kamiyama, Sae [1 ]
Usui, Keisuke [1 ,2 ,3 ]
Suga, Kenta [1 ]
Adachi, Hiroto [1 ]
Arita, Akihiro [1 ]
Sakamoto, Hajime [1 ,3 ]
Kyogoku, Shinsuke [1 ,3 ]
Daida, Hiroyuki [1 ,3 ]
机构
[1] Juntendo Univ, Grad Sch Hlth Sci, Dept Radiol Technol, 1-5-32 Yushima,Bunkyo Ku, Tokyo 1130034, Japan
[2] Juntendo Univ, Fac Med, Dept Radiat Oncol, 1-5-32 Yushima,Bunkyo ku, Tokyo 1130034, Japan
[3] Juntendo Univ, Fac Hlth Sci, Dept Radiol Technol, 1-5-32 Yushima,Bunkyo Ku, Tokyo 1130034, Japan
基金
日本学术振兴会;
关键词
Cone-beam computed tomography; Sparse projections; Conditional generative adversarial network; Image quality correction; Tumor shape reproducibility; Structural similarity index; Peak signal-to-noise ratio; Dice index; Radiation dose reduction; Image artifacts;
D O I
10.1007/s40846-025-00927-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PurposeTo reveal the effectiveness of image correction using a conditional generative adversarial network for sparse-view cone-beam computed tomography (CBCT) images, we generated pseudo-CBCT images with data projection angles ranging from 1 degrees to 20 degrees from CT images and evaluated the image quality and tumor shape reproducibility.MethodsCone beam projection was simulated using multi-slice CT images with the ray summation method, and pseudo-CBCT images were reconstructed for 15 patients. These projections were collected at each rotation angle of 1 degrees- 20 degrees to acquire a sparse-view CBCT image. The dataset comprised paired sparse pseudo-CBCT and original CT images. Overall, 14 and one cases were used in the training and validation datasets, respectively. The structural similarity index (SSIM) and peak signal-to-noise ratio (PSNR) were calculated to evaluate image quality, and the Dice index evaluated tumor shape similarity in the corrected CBCT images.ResultsThe sparse-view CBCT image quality improved, resembling the original CT images. SSIM increased from an average of 0.11 to 0.80, and PSNR improved from 9.50 to 21.2 dB. The dice index improved from 0.79 to 0.82. However, data acquisition at larger sparse projection angles resulted in a blurring of reconstructed tumor shapes, indicating limitations in maintaining structural fidelity.ConclusionConditional generative adversarial networks-based correction significantly improves the image quality and tumor shape reproducibility of sparse-view CBCT images. However, higher projection angles result in structural blurring, suggesting limitations in maintaining tumor shape integrity at larger angles.
引用
收藏
页码:138 / 146
页数:9
相关论文
共 50 条
  • [21] Improving Image Quality of Cone-Beam CT Using Alternating Regression Forest
    Lei, Yang
    Tang, Xiangyang
    Higgins, Kristin
    Wang, Tonghe
    Liu, Tian
    Dhabaan, Anees
    Shim, Hyunsuk
    Curran, Walter J.
    Yang, Xiaofeng
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [22] Enhancing Gamma Knife Cone-beam Computed Tomography Image Quality Using Pix2pix Generative Adversarial Networks: A Deep Learning Approach
    Ramachandran, Prabhakar
    Anderson, Darcie
    Colbert, Zachery
    Arrington, Daniel
    Huo, Michael
    Pinkham, Mark B.
    Foote, Matthew
    Fielding, Andrew
    JOURNAL OF MEDICAL PHYSICS, 2025, 50 (01) : 30 - 37
  • [23] Image Quality and Dose Measurement for Partial Cone-Beam CT
    Abouei, E.
    Ford, N.
    MEDICAL PHYSICS, 2014, 41 (06) : 143 - 143
  • [24] The influence of bowtie filtration on cone-beam CT image quality
    Mail, N.
    Moseley, D. J.
    Siewerdsen, J. H.
    Jaffray, D. A.
    MEDICAL PHYSICS, 2009, 36 (01) : 22 - 32
  • [25] Image quality advances in flat panel cone-beam CT
    Sowards-Emmerd, David
    Elenbaas, Thijs
    Hansis, Eberhard
    van de Haar, Peter
    Shao, Lingxiong
    Timmer, Jan
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [26] The influence of bowtie filtration on cone-beam CT image quality
    Mail, N.
    Moseley, D.
    Siewerdsen, J.
    Jaffray, D.
    MEDICAL PHYSICS, 2007, 34 (06) : 2343 - 2343
  • [27] Improving cone-beam CT quality using a cycle-residual connection with a dilated convolution-consistent generative adversarial network
    Deng, Liwei
    Zhang, Mingxing
    Wang, Jing
    Huang, Sijuan
    Yang, Xin
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (14):
  • [28] Physical performance and image quality of megavoltage cone-beam CT
    Morin, O.
    Aubin, M.
    Aubry, J.
    Bose, S.
    Chen, J.
    Descovich, M.
    Verhey, L.
    Pouliot, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2572 - 2572
  • [29] StegGAN: hiding image within image using conditional generative adversarial networks
    Singh, Brijesh
    Sharma, Prasen Kumar
    Huddedar, Shashank Anil
    Sur, Arijit
    Mitra, Pinaki
    MULTIMEDIA TOOLS AND APPLICATIONS, 2022, 81 (28) : 40511 - 40533
  • [30] StegGAN: hiding image within image using conditional generative adversarial networks
    Brijesh Singh
    Prasen Kumar Sharma
    Shashank Anil Huddedar
    Arijit Sur
    Pinaki Mitra
    Multimedia Tools and Applications, 2022, 81 : 40511 - 40533