High-precision magnetic field measurement system based on a coherent population trapping magnetometer onboard the SATech-01 satellite

被引:0
作者
Xue, Hongbo [1 ,2 ]
Song, Wei [1 ,2 ]
Zhao, Haoran [1 ,2 ]
Zhang, Yiteng [1 ,2 ]
Ye, Shanzhi [1 ,2 ]
Wang, Jindong [1 ,2 ]
Tao, Ran [1 ,2 ]
Sang, Peng [3 ]
Chen, Keli [4 ]
Bi, Xingzi [5 ]
Cheng, Bingjun [1 ,2 ]
Zhou, Bin [1 ,2 ]
Xue, Yongliang [1 ,2 ]
Tang, Yingying [4 ]
Liu, Liu [5 ]
Li, Jinsong [5 ]
Zhu, Xiaocheng [5 ]
Li, Baoquan [3 ]
Liu, Jinguo [4 ]
Chen, Wen [5 ]
Zhang, Xiaofeng [5 ]
Zhang, Yonghe [5 ]
Li, Lei [1 ,2 ]
机构
[1] Chinese Acad Sci, Natl Space Sci Ctr, State Key Lab Space Weather, Beijing 100190, Peoples R China
[2] Chinese Acad Sci, Natl Space Sci Ctr, Key Lab Solar Act & Space Weather, Beijing 100190, Peoples R China
[3] Chinese Acad Sci, Natl Space Sci Ctr, Key Lab Elect & Informat Technol Space Syst, Beijing 100190, Peoples R China
[4] Chinese Acad Sci, Shenyang Inst Automat, State Key Lab Robot, Shenyang 110016, Peoples R China
[5] Chinese Acad Sci, Innovat Acad Microsatellites, Shanghai 201304, Peoples R China
基金
中国国家自然科学基金;
关键词
magnetic field measurement system; coherent population trapping magnetometer; anisotropic magnetoresistance magnetometer; nano star tracker; non-magnetic telescopic tubular mast; satellite; SWARM;
D O I
10.1007/s11431-024-2832-7
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
On July 27, 2022, a high-precision system for measuring the magnetic field based on a coherent population trapping magnetometer (referred to as the CPT system) was launched onboard the Space Advanced Technology demonstration satellite (SATech-01) by a ZK-1A rocket. The payload comprises a scalar coherent population trapping magnetometer (CPTM), triaxial anisotropic magnetoresistance magnetometer (AMRM), and nano star tracker mounted on a non-magnetic telescopic tubular mast. This configuration enables synchronized measurement of scalar and vector geomagnetic fields, as well as the attitude, making the payload with its compact sensors suitable for applications on miniature satellite platforms. On November 7, 2022, the novel telescopic tubular mast was deployed in orbit, extending to a length of 5.28 m. The CPTM, an absolute scalar magnetometer with an omnidirectional sensor, is the first China-developed quantum/atomic magnetometer successfully operating in space. In orbit, the CPTM has sensitivity of similar to 10 pT/Hz1/2 and can automatically operate under complex magnetic field variations. The difference between the scalar fields obtained using the CPTM and CHAOS model has a mean deviation of -3.73 nT and a standard deviation of 26.11 nT (1 sigma), without on-orbit calibration or correction. The miniaturized AMRM has a sensitivity of similar to 0.3 nT/Hz1/2 and maintains stable and reliable operation in orbit. The low-power and miniaturized nano star tracker has a measurement uncertainty of 14.23 '' (1 sigma) in orbit. The mission has realized the on-orbit technical verification of the integrated and synchronized detection of the vector magnetic field and attitude and fully validated the system's performance, automation level, and reliability.
引用
收藏
页数:16
相关论文
共 26 条
  • [1] Coherent population trapping in laser spectroscopy
    Arimondo, E
    [J]. PROGRESS IN OPTICS, VOL XXXV, 1996, 35 : 257 - 354
  • [2] Dead-Zone-Free Atomic Magnetometry with Simultaneous Excitation of Orientation and Alignment Resonances
    Ben-Kish, A.
    Romalis, M. V.
    [J]. PHYSICAL REVIEW LETTERS, 2010, 105 (19)
  • [3] Ultralight deployable booms for solar sails and other large gossamer structures in space
    Block, Joachim
    Straubel, Marco
    Wiedemann, Martin
    [J]. ACTA ASTRONAUTICA, 2011, 68 (7-8) : 984 - 992
  • [4] High precision magnetometer for geomagnetic exploration onboard of the China Seismo-Electromagnetic Satellite
    Cheng, BingJun
    Zhou, Bin
    Magnes, Werner
    Lammegger, Roland
    Pollinger, Andreas
    [J]. SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2018, 61 (05) : 659 - 668
  • [5] Swarm -: An Earth Observation Mission investigating Geospace
    Friis-Christensen, E.
    Luehr, H.
    Knudsen, D.
    Haagmans, R.
    [J]. ADVANCES IN SPACE RESEARCH, 2008, 41 (01) : 210 - 216
  • [6] Microfabricated Vapor Cells with Reflective Sidewalls for Chip Scale Atomic Sensors
    Han, Runqi
    You, Zheng
    Zhang, Fan
    Xue, Hongbo
    Ruan, Yong
    [J]. MICROMACHINES, 2018, 9 (04):
  • [7] Loop-locked coherent population trapping magnetometer based on a fiber electro-optic modulator
    Hu, Yong
    Feng, Y. Y.
    Xu, Chi
    Xue, H. B.
    Sun, Li
    [J]. APPLIED OPTICS, 2014, 53 (10) : 2158 - 2162
  • [8] Dynamic Analysis and Parametric Optimization of Telescopic Tubular Mast Applied on Solar Sail
    Ji, Chenyang
    Liu, Jinguo
    Wu, Chenchen
    Zhao, Pengyuan
    Chen, Keli
    [J]. CHINESE JOURNAL OF MECHANICAL ENGINEERING, 2023, 36 (01)
  • [9] Recent Developments of Magnetoresistive Sensors for Industrial Applications
    Jogschies, Lisa
    Klaas, Daniel
    Kruppe, Rahel
    Rittinger, Johannes
    Taptimthong, Piriya
    Wienecke, Anja
    Rissing, Lutz
    Wurz, Marc Christopher
    [J]. SENSORS, 2015, 15 (11) : 28665 - 28689
  • [10] A magnetometer based on quantum interference effects
    Lammegger, R
    Hatzl, S
    Huss, AF
    Windholz, L
    [J]. 13th International School on Quantum Electronics: Laser Physics and Applications, 2005, 5830 : 176 - 180