Experimental and numerical investigation of a cold-formed steel system used to restore old buildings floor

被引:0
作者
Fahmy, Ahmed Shamel [1 ]
Swelem, Sherine Mostafa [1 ]
Farrag, Rowida Saad [2 ]
Mobarak, Wael F. M. [3 ]
机构
[1] Alexandria Univ, Fac Engn, Dept Civil Engn, Alexandria, Egypt
[2] Higher Inst Engn & Technol, Dept Constructing Engn, Alexandria, Egypt
[3] Univ Business & Technol, Civil Engn Dept, Jeddah, Saudi Arabia
来源
SCIENTIFIC REPORTS | 2024年 / 14卷 / 01期
关键词
Restoration; Cold formed; Flooring system; Experimental; Steel decking; COMPOSITE BEAMS; FLEXURAL BEHAVIOR; DESIGN; SECTIONS; CHANNELS; TESTS; WEB;
D O I
10.1038/s41598-024-81674-7
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This paper presents a novel configuration of built-up cold-formed steel (CFS) flooring system in the shape of a box section. A new technique is applied to produce the components of the flooring system, which are fastened by self-drilling screws. This box section consists of a cast-in-situ concrete slab, trapezoidal steel decking, two sigma section, steel plate and stiffening equal angles. The main objectives of this system is to enable rapid construction and decrease the time, requirements, and cost. As a result, the proposed system is designed to use the decking in a longitudinal direction. Many old buildings have sturdy structures but their floors were ruined due to being fabricated from timber. This flooring system will be implemented to increase their quality of life and be reused. The loading experiments of four specimens were carried out. The failure modes of the CFS flooring system, load-deflection relation curves, longitudinal strain distribution at different heights were obtained. The experimental results show that the flooring system has high stiffness and flexural performance and can reach ultimate strength without local buckling failure. The failure occurs due to distortion at the end supports. Then, the capacity of the flooring system was calculated theoretically. Then, the practical and theoretical results were compared. The calculated results agree well with the test results. A three-dimensional finite element model is also established to investigate structural performance of the proposed system.
引用
收藏
页数:20
相关论文
共 52 条
  • [1] ABDELSAYED G, 1982, J STRUCT DIV-ASCE, V108, P2609
  • [2] The evolution of composite flooring systems: applications, testing, modelling and eurocode design approaches
    Ahmed, Inas Mahmood
    Tsavdaridis, Konstantinos Daniel
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 155 : 286 - 300
  • [3] Simulation of flexural behaviour and design of cold-formed steel closed built-up beams composed of two sigma sections for local buckling
    Anbarasu, M.
    [J]. ENGINEERING STRUCTURES, 2019, 191 : 549 - 562
  • [4] [Anonymous], 2017, AISI S905
  • [5] ANSYS Inc, 2022, ANSYS Software (Version 2022)
  • [6] Antony AG., 2016, Int. J. Innovative Res. Sci. Eng. Technol, V5, P16249
  • [7] Testing, numerical and analytical modelling of self-drilling screw connections between thin steel sheets in shear
    Cai, Kangyi
    Yuan, Huanxin
    [J]. THIN-WALLED STRUCTURES, 2023, 182
  • [8] canam-construction, About us
  • [9] Structural behaviour and capacity of cold-formed steel channel sections with elongated edge-stiffened and unstiffened web holes under compression
    Chandramohan, Dinesh Lakshmanan
    Roy, Krishanu
    Ananthi, G. Beulah Gnana
    Fang, Zhiyuan
    Lim, James B. P.
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 218
  • [10] Chandrikka V., 2019, Int. J. Sci. Eng. Sci, V3, P5