A novel patient-specific free-hand method using fluoroscopic templating for accurate cup placement in supine position total hip arthroplasty

被引:0
|
作者
Kazuhiko Sonoda [1 ]
Yusuke Kubo [1 ]
Toshihiko Hara [1 ]
机构
[1] Department of Orthopaedic Surgery, Iizuka Hospital, 3-83 Yoshiomachi, Iizuka
关键词
Accuracy; Cup; Intraoperative fluoroscopy; Supine position; Total hip arthroplasty;
D O I
10.1007/s00402-025-05828-6
中图分类号
学科分类号
摘要
Introduction: We developed a fluoroscopic templating technique for accurate cup placement based on the acetabular morphology of individual patients during supine position total hip arthroplasty (THA) to reduce the risk of dislocation. This study aimed to evaluate cup positioning accuracy with and without this technique. Materials and methods: We evaluated 75 consecutive hips of 70 patients undergoing cementless anterolateral supine THA. The target angle for radiographic inclination (RI) and radiographic anteversion (RA) were set using a computed tomography (CT)-based functional pelvic plane. In 25 hips, we implanted the cup using a mechanical alignment guide (C-group). A fluoroscopic templating technique was used in 50 hips (FT-group), and a reference line based on the acetabular morphology was preoperatively set in each patient for the RI guide. A reference diagram was made for the RA guide. Postoperative CT scans were used to compare cup positioning accuracy between groups. Results: The absolute values of the error from the target angle were 3.2 ± 2.0° (RI) and 6.5 ± 3.8° (RA) in the C-group, and 1.5 ± 1.2° (RI) and 2.6 ± 1.9° (RA) in the FT-group. The errors of both RI and RA were significantly smaller in the FT-group than in the C-group. The rates of cases within ± 5° of the target angles for both RI and RA were 48% (C-group) and 92% (FT-group). The mean fluoroscopic times were 32.2 s (C-group) and 17.4 s (FT-group). Conclusion: Our simple patient-specific technique achieved accurate cup positioning; this may reduce the risk of dislocation. © The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature 2025.
引用
收藏
相关论文
共 31 条
  • [21] A novel calibration method for digital templating of total hip arthroplasty: a prospective clinical study of dual scale type single marker calibration in supine radiographs
    Loweg, Lemmard
    Trost, Matthias
    Kutzner, Karl Philipp
    Ries, Christian
    Boese, Christoph Kolja
    INTERNATIONAL ORTHOPAEDICS, 2020, 44 (09) : 1693 - 1699
  • [22] A novel imageless accelerometer-based navigation system improves acetabular cup placement accuracy during total hip arthroplasty in the lateral decubitus position
    Ohyama, Yohei
    Minoda, Yukihide
    Sugama, Ryo
    Masuda, Sho
    Ohta, Yoichi
    Nakamura, Hiroaki
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (06) : 2865 - 2872
  • [23] Accuracy of patient-specific template-guided vs. free-hand fluoroscopically controlled pedicle screw placement in the thoracic and lumbar spine: a randomized cadaveric study
    Mazda Farshad
    Michael Betz
    Nadja A. Farshad-Amacker
    Manuel Moser
    European Spine Journal, 2017, 26 : 738 - 749
  • [24] Early outcomes of total hip arthroplasty using point-of-care manufactured patient-specific instruments: a single university hospital's initial experience
    Trung, Hieu Pham
    Sy Quyen, Nang Vo
    Tu, Nam Vu
    Trung, Dung Tran
    Dinh, Toan Duong
    BMC SURGERY, 2023, 23 (01)
  • [25] Accuracy of patient-specific template-guided vs. free-hand fluoroscopically controlled pedicle screw placement in the thoracic and lumbar spine: a randomized cadaveric study
    Farshad, Mazda
    Betz, Michael
    Farshad-Amacker, Nadja A.
    Moser, Manuel
    EUROPEAN SPINE JOURNAL, 2017, 26 (03) : 738 - 749
  • [26] Accuracy of Cup Placement Angle, Leg Lengthening, and Offset Measurement Using an AR-Based Portable Navigation System: Validation in Supine and Lateral Decubitus Positions for Total Hip Arthroplasty
    Ozaki, Yusuke
    Yamamoto, Takeaki
    Kimura, Satomi
    Kasai, Toru
    Niki, Rintaro
    Niki, Hisateru
    MEDICINA-LITHUANIA, 2024, 60 (10):
  • [27] Accuracy of cup placement and pelvic motion in total hip arthroplasty in the lateral decubitus position using a new computed tomography-based navigation system with augmented reality technology
    Yohei Naito
    Masahiro Hasegawa
    Shine Tone
    Hiroki Wakabayashi
    Akihiro Sudo
    Archives of Orthopaedic and Trauma Surgery, 2024, 144 : 2381 - 2389
  • [28] Accuracy of cup placement and pelvic motion in total hip arthroplasty in the lateral decubitus position using a new computed tomography-based navigation system with augmented reality technology
    Naito, Yohei
    Hasegawa, Masahiro
    Tone, Shine
    Wakabayashi, Hiroki
    Sudo, Akihiro
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (05) : 2381 - 2389
  • [29] Early outcomes of total hip arthroplasty using point-of-care manufactured patient-specific instruments: a single university hospital’s initial experience
    Hieu Pham Trung
    Nang Vo Sy Quyen
    Nam Vu Tu
    Dung Tran Trung
    Toan Duong Dinh
    BMC Surgery, 23
  • [30] Pedicle screw insertion with patient-specific 3D-printed guides based on low-dose CT scan is more accurate than free-hand technique in spine deformity patients: a prospective, randomized clinical trial
    Cecchinato, Riccardo
    Berjano, Pedro
    Zerbi, Alberto
    Damilano, Marco
    Redaelli, Andrea
    Lamartina, Claudio
    EUROPEAN SPINE JOURNAL, 2019, 28 (07) : 1712 - 1723