A novel patient-specific free-hand method using fluoroscopic templating for accurate cup placement in supine position total hip arthroplasty

被引:0
|
作者
Kazuhiko Sonoda [1 ]
Yusuke Kubo [1 ]
Toshihiko Hara [1 ]
机构
[1] Department of Orthopaedic Surgery, Iizuka Hospital, 3-83 Yoshiomachi, Iizuka
关键词
Accuracy; Cup; Intraoperative fluoroscopy; Supine position; Total hip arthroplasty;
D O I
10.1007/s00402-025-05828-6
中图分类号
学科分类号
摘要
Introduction: We developed a fluoroscopic templating technique for accurate cup placement based on the acetabular morphology of individual patients during supine position total hip arthroplasty (THA) to reduce the risk of dislocation. This study aimed to evaluate cup positioning accuracy with and without this technique. Materials and methods: We evaluated 75 consecutive hips of 70 patients undergoing cementless anterolateral supine THA. The target angle for radiographic inclination (RI) and radiographic anteversion (RA) were set using a computed tomography (CT)-based functional pelvic plane. In 25 hips, we implanted the cup using a mechanical alignment guide (C-group). A fluoroscopic templating technique was used in 50 hips (FT-group), and a reference line based on the acetabular morphology was preoperatively set in each patient for the RI guide. A reference diagram was made for the RA guide. Postoperative CT scans were used to compare cup positioning accuracy between groups. Results: The absolute values of the error from the target angle were 3.2 ± 2.0° (RI) and 6.5 ± 3.8° (RA) in the C-group, and 1.5 ± 1.2° (RI) and 2.6 ± 1.9° (RA) in the FT-group. The errors of both RI and RA were significantly smaller in the FT-group than in the C-group. The rates of cases within ± 5° of the target angles for both RI and RA were 48% (C-group) and 92% (FT-group). The mean fluoroscopic times were 32.2 s (C-group) and 17.4 s (FT-group). Conclusion: Our simple patient-specific technique achieved accurate cup positioning; this may reduce the risk of dislocation. © The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature 2025.
引用
收藏
相关论文
共 31 条
  • [1] A Fluoroscopic Grid in Supine Total Hip Arthroplasty Improving Cup Position, Limb Length, and Hip Offset
    Gililland, Jeremy M.
    Anderson, Lucas A.
    Boffeli, Shannon L.
    Pelt, Christopher E.
    Peters, Christopher L.
    Kubiak, Erik N.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (08) : 111 - 116
  • [2] Accuracy of Acetabular Cup Placement During Total Hip Arthroplasty in Supine Position Using a Pelvic Rotation Correction Device
    Nakasone, Satoshi
    Takaesu, Mika
    Ishihara, Masato
    Onaga, Masamichi
    Igei, Takahiro
    Miyata, Yoshihide
    Nishida, Kotaro
    ARTHROPLASTY TODAY, 2022, 16 : 46 - 52
  • [3] Accuracy of acetabular cup placement during anterolateral supine total hip arthroplasty using intraoperative fluoroscopy: a retrospective study
    Cho, Eiji
    Hisatome, Takashi
    Oda, Shuhei
    Fujimaki, Hirohisa
    Nakanishi, Kazuyoshi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [4] Accuracy of acetabular cup placement during anterolateral supine total hip arthroplasty using intraoperative fluoroscopy: a retrospective study
    Eiji Cho
    Takashi Hisatome
    Shuhei Oda
    Hirohisa Fujimaki
    Kazuyoshi Nakanishi
    Journal of Orthopaedic Surgery and Research, 17
  • [5] Accuracy comparison of cup positioning during total hip arthroplasty using Hip Align and AR-Hip in the supine position
    Fujita, Masahiro
    Hayashi, Shinya
    Kuroda, Yuichi
    Nakano, Naoki
    Maeda, Toshihisa
    Matsushita, Takehiko
    Matsumoto, Tomoyuki
    Kuroda, Ryosuke
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (12) : 7229 - 7235
  • [6] Accuracy comparison of cup positioning during total hip arthroplasty using Hip Align and AR-Hip in the supine position
    Masahiro Fujita
    Shinya Hayashi
    Yuichi Kuroda
    Naoki Nakano
    Toshihisa Maeda
    Takehiko Matsushita
    Tomoyuki Matsumoto
    Ryosuke Kuroda
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 7229 - 7235
  • [7] Comparison of accuracy of cup position using portable navigation versus alignment guide in total hip arthroplasty in supine position
    Okamoto, Masanori
    Kawasaki, Masashi
    Okura, Toshiaki
    Ochiai, Satoshi
    Yokoi, Hiroyuki
    HIP INTERNATIONAL, 2021, 31 (04) : 492 - 499
  • [8] Patient Obesity Influences Pelvic Lift During Cup Insertion in Total Hip Arthroplasty Through a Lateral Transgluteal Approach in Supine Position
    Brodt, Steffen
    Nowack, Dimitri
    Jacob, Benjamin
    Krakow, Linda
    Windisch, Christoph
    Matziolis, Georg
    JOURNAL OF ARTHROPLASTY, 2017, 32 (09) : 2762 - 2767
  • [9] Accurate cup placement using a portable navigation system during total hip arthroplasty based on pelvic orientation in the lateral decubitus position
    Tsukamoto, Manabu
    Kawasaki, Makoto
    Suzuki, Hitoshi
    Fujitani, Teruaki
    Uchida, Soshi
    Sakai, Akinori
    ARTIFICIAL ORGANS, 2022, 46 (12) : 2412 - 2422
  • [10] A Novel Technique for Autograft Preparation Using Patient-Specific Instrumentation (PSI) Assistance in Total Hip Arthroplasty in Developmental Dysplasia of Hip (DDH)
    Lin, Chun-Ru
    Chou, Hsuan
    Luo, Chu-An
    Chang, Shu-Hao
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (09):