Fire-resistance design and experimental research for the stay cables of super-long span cable-stayed bridge

被引:0
|
作者
Shen, Kongjian [1 ,2 ,3 ]
Jiang, Zhenxiong [1 ]
Zhao, Jun [4 ]
Zhou, Zhubing [4 ]
Wu, Qiong [4 ]
Qiang, Qiang [4 ]
Wang, Hongchao [4 ]
机构
[1] Jiangsu Prov Transportat Engn Construct Bur, Nanjing 210004, Peoples R China
[2] China Railway Bridge & Tunnel Technol Co Ltd, Nanjing 210061, Jiangsu, Peoples R China
[3] Southeast Univ, Natl Key Lab Safety Durabil & Hlth Operat Long Spa, Nanjing 210096, Peoples R China
[4] Jiangsu Fasten Steel Cable Co Ltd, Jiangyin 214445, Peoples R China
来源
ADVANCES IN BRIDGE ENGINEERING | 2025年 / 6卷 / 01期
基金
国家重点研发计划;
关键词
Cable-stayed bridge; Stay cable; Fire-resistant performance; Structural system design; Fire resistance test;
D O I
10.1186/s43251-024-00153-1
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The cables are crucial to the service life of cable supported bridges. Fire accidents involving bridge cables may cause severe damage, impacting the structural integrity and performance of bridges, and therefore requires thorough attention and research. This research mainly focuses on the key technologies for the fire resistance of stay cables, including the structural system design of fire-resistant stay cables, selection of fireproof materials, and experimental verification of fire-resistant performance and qualification of the proposed system. The results show that the multiple wrapped composite structures with fire resistance are suitable for the fire-resistant design of stay cables in the Changtai Yangtze River Bridge. The fire-resistant structure of the stay cables is designed as one layer of flame barrier layer using 316L matte stainless steel, one layer of fire retardant layer using modified ceramic fiber cloth and two layers of insulation layer using aluminum foil glass fiber cloth. Moreover, the fire-resistant performance of the structural system is experimentally validated to meet the design requirements that the fire-resistant time of the stay cables should not be less than 60 min, and the temperature of the internal steel wire should not exceed 300 degrees C. Meanwhile, tensile testing under high temperature demonstrates that the designed stay cable can resist the applied load for 60 min under a high temperature of 300 degrees C at the surface of cable without slip or failure of anchorage components. The development of fireproof stay cable products, as applied in the Changtai Yangtze River Bridge project, provides a valuable reference for fire resistance design of bridge cables and contributes significant economic and social benefits.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] Lateral constraint systems for super-long-span cable-stayed bridge
    Ye, Ai-Jun
    Fan, Li-Chu
    Zhongguo Gonglu Xuebao/China Journal of Highway and Transport, 2007, 20 (02): : 63 - 67
  • [22] STATIC BEHAVIOR OF LONG-SPAN RC CABLE-STAYED BRIDGE WITH FRP CABLES
    Wang, Xin
    Zeng, Fan-Xing
    Wu, Zhi-Shen
    INNOVATION & SUSTAINABILITY OF STRUCTURES, VOLS 1 AND 2, 2011, : 957 - 964
  • [23] Nonlinear FEM and Control Method for Super-Long Span Three Main Trusses and Three Cable Planes Railway Cable-Stayed Bridge
    Yang, Zhishuo
    Ye, Meixin
    Zhou, Yanqun
    Ou, Li
    ADVANCES IN CIVIL ENGINEERING, PTS 1-6, 2011, 255-260 : 1065 - 1069
  • [24] Calculation method of buffeting response for stay cables of long⁃span cable⁃stayed bridge
    Guo S.-L.
    Zhong T.-Y.
    Yan Z.-G.
    Jilin Daxue Xuebao (Gongxueban)/Journal of Jilin University (Engineering and Technology Edition), 2021, 51 (05): : 1756 - 1762
  • [25] Static and Dynamic Characteristics of a Long-Span Cable-Stayed Bridge with CFRP Cables
    Xie, Xu
    Li, Xiaozhang
    Shen, Yonggang
    MATERIALS, 2014, 7 (06) : 4854 - 4877
  • [26] Condition assessment of long span cable-stayed bridge
    Wu H.-C.
    Xiang Y.-Q.
    Wang J.-F.
    Journal of Zhejiang University-SCIENCE A, 2006, 7 (Suppl 2): : 297 - 308
  • [27] Research on Configuration of Stay Cables and Hanger Cables Intersection Zones in Hybrid Cable-Stayed Suspension Bridge
    Xiao H.
    He D.
    Bridge Construction, 2023, 53 : 58 - 64
  • [28] Study on the safety assessment method for stay cables of long-span cable-stayed bridges
    Tianjin University, Tianjin 300072, China
    不详
    Tumu Gongcheng Xuebao, 2006, 9 (74-79):
  • [29] MECHANICS PERFORMANCE OF SUPER LONG-SPAN CABLE-STAYED BRIDGES USING CFRP CABLES
    Zhang, Xin-Jun
    Dong, Ling-Long
    PROCEEDINGS OF THE TENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS I AND II, 2008, : 1679 - 1683
  • [30] Evaluation of FRP and hybrid FRP cables for super long-span cable-stayed bridges
    Wang, Xin
    Wu, Zhishen
    COMPOSITE STRUCTURES, 2010, 92 (10) : 2582 - 2590